Brazilian Journal of Radiation Sciences2025
Automated dose-effect calibration curve for X-rays using the cytokinesis-block micronucleus assay
F. A. Chaves-Campos, F. Ortíz-Morales, J. Gómez-Castro, A. Cordero-Ramírez e J. E. González-Mesa
em inglês
resumo
This article shows the development of a dose–effect calibration curve for X-ray exposures ranging from 0 to 4 Gy using the cytokinesis-block micronucleus assay and automated analysis—the first effort of its kind reported in Latin America. This work establishes a regional benchmark for high-throughput methodologies in cytogenetic biodosimetry, highlighting their potential to improve operational efficiency and reduce response times in radiological emergencies. Methods: Blood samples from six healthy donors were irradiated with X-rays at seven dose levels (0–4 Gy) using a calibrated 6 MV linear accelerator. Two blind samples (1.5 and 3 Gy) were included for validation. The CBMN assay was performed following IAEA protocols, DAPI-stained slides were analyzed using a AxioImager.Z2 automated microscope integrated with MetaSystems Metafer4 and the MNScoreX classifier software. A negative binomial regression model (NB1) was used for model fitting, accounting for overdispersion in micronucleus (MN) frequency. Results: Automated scoring of binucleated lymphocytes showed a dose-dependent increase in MN frequency. The fitted model followed a linear–quadratic relationship: Y = 0.0545 + 0.0448·D + 0.0145·D 2 , with all coefficients statistically significant (p < 0.001). Dose estimates for blinded samples (1.5 and 3 Gy) matched the true doses within 95% confidence intervals, with all z-scores < |3|. Conclusions: The resulting linear–quadratic dose–response curve enabled accurate estimation of blinded sample doses, with all z-scores falling within acceptable fitness-for-purpose thresholds. These results underscore the value of combining automated microscopy with robust statistical modeling to achieve reliable dose assessment, particularly in high-throughput settings and radiological emergency scenarios.
como citar · ABNT NBR 6023
CHAVES-CAMPOS, F. A. et al. Automated dose-effect calibration curve for X-rays using the cytokinesis-block micronucleus assay. Brazilian Journal of Radiation Sciences, 2025. DOI: 10.15392/2319-0612.2025.2908.
Referências
28 obras citadas
- 1S. Sommer, I. Buraczewska e M. Kruszewski. Micronucleus assay: The state of art, and future directions. Int J Mol Sci, 2020quem mais cita →
- 2A. Vral, M. Fenech e H. Thierens. The micronucleus assay as a biological dosimeter of in vivo ionising radiation exposure. Mutagenesis, 2011quem mais cita →
- 3International Atomic Energy Agency. Cytogenetic Dosimetry: Applications in Preparedness for and Response to Radiation Emergencies. 2011quem mais cita →
- 4J. D. Tucker, M. Vadapalli, M. C. Joiner e mais 3. Estimating the Lowest Detectable Dose of Ionizing Radiation by the Cytokinesis-Block Micronucleus Assay. Radiat Res, 2013quem mais cita →
- 5G. Tamizh Selvan e P. Venkatachalam. Potentials of cytokinesis blocked micronucleus assay in radiation triage and biological dosimetry. Journal of Genetic Engineering and Biotechnology, 2024quem mais cita →
- 6C. Beinke, M. Port e M. Abend. Automatic versus manual lymphocyte fixation: impact on dose estimation using the cytokinesis-block micronucleus assay. Radiat Environ Biophys, 2015quem mais cita →
- 7M. Rodrigues, L. Beaton-Green, R. Wilkins e mais 1. The potential for complete automated scoring of the cytokinesis block micronucleus cytome assay using imaging flow cytometry. Mutation Research/Genetic Toxicology and Environmental Mutagenesis, 2018quem mais cita →
- 8N. Asano, Y. Katsuma, H. Tamura e mais 2. An automated new technique for scoring the rodent micronucleus assay: computerized image analysis of acridine orange supravitally stained peripheral blood cells. Mutation Research/Fundamental and Molecular Mechanisms of Mutagenesis, 1998quem mais cita →
- 9H. F. Stich, A. B. Acton e B. Palcic. Towards an Automated Micronucleus Assay as an Internal Dosimeter for Carcinogen-Exposed Human Population Groups. Occupational Cancer Epidemiology, 1990quem mais cita →
- 10D. Varga. An automated scoring procedure for the micronucleus test by image analysis. Mutagenesis, 2004quem mais cita →
- 11I. Decordier, A. Papine, G. Plas e mais 9. Automated image analysis of cytokinesis-blocked micronuclei: an adapted protocol and a validated scoring procedure for biomonitoring. Mutagenesis, 2008quem mais cita →
- 12H. Thierens e A. Vral. The micronucleus assay in radiation accidents. Ann Ist Super Sanita, 2009quem mais cita →
- 13P. Willems, L. August, J. Slabbert e mais 4. Automated micronucleus (MN) scoring for population triage in case of large scale radiation events. Int J Radiat Biol, 2010quem mais cita →
- 14F.-A. Chaves-Campos, F. Ortíz-Morales, R. Mejías-Gamboa e mais 5. Dose-effect calibration curve for high X-ray doses using the Calyculin-A chromosome premature condensation assay. Brazilian Journal of Radiation Sciences, 2024quem mais cita →
- 15J. E. González Mesa, F. Ortíz-Morales, O. García-Lima e mais 24. LBDNet interlaboratory comparison for the dicentric chromosome assay by digitized image analysis applying weighted robust statistical methods. Int J Radiat Biol, 2024quem mais cita →
- 16International Atomic Energy Agency. Absorbed dose determination in external beam radiotherapy: An international code of practice for dosimetry based on standards of absorbed dose to water. 2000quem mais cita →
- 17W. Vargas-Segura, A. Cordero-Ramírez e E. Avendaño-Soto. Procedure for calibration curve determination of radiochromic films for routine QA in Superficial Therapy X-Ray equipment. British Journal of Medical and Health Research, 2024quem mais cita →
- 18International Atomic Energy Agency. Dosimetry of Small Static Fields Used in External Beam Radiotherapy: An International Code of Practice for Reference and Relative Dose Determination. 2017quem mais cita →
- 19RStudio Team. RStudio: Integrated Development for R. 2020quem mais cita →
- 20A. Hernández, D. Endesfelder, J. Einbeck e mais 8. Biodose Tools: an R shiny application for biological dosimetry. Int J Radiat Biol, 2023quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda