Brazilian Journal of Radiation Sciences2025
Addressing Operational Changes in Time and Radioactive Activity Administered Following the Introduction of PET-CT Equipment with New Technologies: A Retrospective Analysis
D. Coiro da Silva, Songeli M. Freire, A. Galvão Bueno, A. Sanches Melo, A. Fujimori Coiro, A. López Díaz e R. Meyer
em inglês
resumo
Abstract Decreased radioactive activity to be injected in individuals for diagnostic exams performed on Positrons emission Tomography associated with Computed Tomography is becoming mandatory since the patient protection is one of the pillars for Radiation Protection. The technological advance opens the possibility to demonstrate this activity reduction as well as time reduction during the exam, which allow a better convenience to population, and still maintaining the quality of the diagnose. This study investigates operational changes observed after the introduction of a new PET-CT scanner (PET2), focusing on reductions in administered radioactive activity and acquisition time. The results show significant decreases in these parameters compared to a prior system (PET1). The scope of the study is limited to describing these operational impacts, based on the maintenance of diagnostic image quality support by the physician criteria.
como citar · ABNT NBR 6023
COIRO DA SILVA, D. et al. Addressing Operational Changes in Time and Radioactive Activity Administered Following the Introduction of PET-CT Equipment with New Technologies: A Retrospective Analysis. Brazilian Journal of Radiation Sciences, 2025. DOI: 10.15392/2319-0612.2025.2796.
Referências
24 obras citadas
- 1UNSCEAR. UNSCEAR 2020/2021: Report to the General Assembly with Scientific, vol I. Annexes A. Evaluation of medical exposure to ionizing radiation. 2022quem mais cita →
- 2S. R. O'Brien e D. A. Mankoff. Nuclear Medicine Cancer Care-Current Status and Future Directions for Radiopharmaceutical Diagnostics and Theranostics for Cancer. The Cancer Journal, 2024quem mais cita →
- 3IAEA. IAEA Safety Reports Series No. 112 Patient radiation exposure monitoring in medical imaging. STI/PUB/1976, 2023quem mais cita →
- 4A. López, D. Corio, D. E. González e mais 3. Niveles de Referencia para Diagnóstico según PUBMED: ¿es suficiente la información disponible?. J Health Med Sci, 2023quem mais cita →
- 5IAEA. NORMAS DE SEGURIDAD DEL OIEA No SSG-46. PROTECCIÓN Y SEGURIDAD RADIOLÓGICAS EN LOS USOS MÉDICOS DE LA RADIACIÓN IONIZANTE. 2022quem mais cita →
- 6ACR–AAPM–SPR commission. ACR-AAPM-SPR PRACTICE PARAMETER FOR DIAGNOSTIC REFERENCE LEVELS AND ACHIEVABLE DOSES IN MEDICAL X-RAY IMAGING. 2023quem mais cita →
- 7E. Loughman, S. Maguire, P. Hastings e mais 1. The impact of digital PET on radiation protection requirements in PET\CT facilities. Physica Medica: European Journal of Medical Physics, 2024quem mais cita →
- 8ANVISA. Farmacopeia Brasileira. 2019quem mais cita →
- 9Inc Siemens Medical Solutions USA. BiographTM TruePoint PET-CT. 2019quem mais cita →
- 10Siemens Healthcare GmbH. Biograph Vision 450. 2021
- 11G. Fardipour Raki, M. Ghahremani Gol, M. Sahraei e mais 1. SiPM and PMT driving, signals count, and peak detection circuits, suitable for particle detection. Journal of Instrumentation, 2022quem mais cita →
- 12IBM Corporation. IBM SPSS Statistics 20 Documentation. Product Documentation, 2016quem mais cita →
- 13Bárbara Juarez Amorim, Juliano Cerci, Elaine Bortoleti de Araújo e mais 3. GUIDELINE PARA PET/CT FDG-18F. 2016quem mais cita →
- 14R. Vali, A. Alessio, R. Balza e mais 3. SNMMI Procedure Standard/EANM Practice Guideline on Pediatric 18F-FDG PET/CT for Oncology 1.0. Journal of Nuclear Medicine, 2021quem mais cita →
- 15K. Waqas, P. M. M. Van Haard, J. W. A. Postema e mais 1. Diabetes mellitus-related fractional glucose uptake in men and women imaged with 18F-FDG PET-CT. J Endocr Soc, 2019quem mais cita →
- 16A. Ahmed, M. Ali, H. Salah e mais 3. Evaluation of uptake values of FDG: Body surface area Vs. body weight correction. Radiation Physics and Chemistry, 2022quem mais cita →
- 17G. P. M. Keramida. The appropriate whole body metric for calculating standardised uptake value and the influence of sex. Nucl Med Commun, 2019quem mais cita →
- 18E. Vañó, D. L. Miller, C. J. Martin e mais 3. ICRP Publication 135: Diagnostic Reference Levels in Medical Imaging. Ann ICRP, 2017quem mais cita →
- 19Z. H. Amador Balbona, A. López Díaz e L. A. Torres Aroche. Niveles de referencia para diagnóstico en medicina nuclear e imagen híbrida. Revisión y actualización. Nucleus, 2022quem mais cita →
- 20M. K. Singh. A review of digital PET-CT technology: Comparing performance parameters in SiPM integrated digital PET-CT systems. Radiography, 2024quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda