Dental Press Journal of Orthodontics2018
The T-loop in details
Amanda Frizzo Viecilli e Maria Perpétua Mota Freitas
em inglês
citado por 2 artigoscita 31 obras
resumo
ABSTRACT Introduction: The T-loop as designed by Burstone is a space closure spring used in the rational application of orthodontic biomechanics. Despite the diversity of studies, there is still no consensus on the optimal parametric characteristics for its conformation. Objective: This study aimed at reviewing the literature on the force systems released by different conformations of the T-loop, according to the type of anchorage and the main characteristics and factors that influence them. Results: Comparing the studies, the need for standardization was perceived in the methodology to shape the loops, regarding the variables that influence the force system. Most of the experimental studies with this loop do not report the vertical movement, nor the steps and angles that occur in the brackets. Clinical studies have obtained more variable results in relation to vertical acting forces, considering the influence of chewing. Conclusion: There is great potential for future studies with this type of loop, especially using nickel-titanium alloys, in order to achieve a pure translational movement without friction, with optimal and constant levels of force.
como citar · ABNT NBR 6023
VIECILLI, Amanda Frizzo; FREITAS, Maria Perpétua Mota. The T-loop in details. Dental Press Journal of Orthodontics, 2018. DOI: 10.1590/2177-6709.23.1.108-117.SAR.
Referências
31 obras citadas
- 1CJ Burstone e AJ Goldberg. Maximum forces and deflections from orthodontic appliances. Am J Orthod, 1983quem mais cita →
- 2AJ Kuhlberg e CJ Burstone. T-loop position and anchorage control. Am J Orthod Dentofacial Orthop, 1997quem mais cita →
- 3K Tanne, M Sakuda e C Burstone. Three-dimensional finite element analysis for stress in the periodontal tissue by orthodontic forces. Am J Orthod Dentofac Orthop, 1987quem mais cita →
- 4CJ Burstone. Rationale of the segmented arch. Am J Orthod, 1962quem mais cita →
- 5CJ Burstone e HA Koenig. Optimizing anterior and canine retraction. Am J Orthod, 1976quem mais cita →
- 6CJ Burstone. The segmented arch approach to space closure. Am J Orthod, 1982quem mais cita →
- 7RL Christiansen e CJ Burstone. Centers of rotation within the periodontal space. Am J Orthod, 1969quem mais cita →
- 8Y Ren, JC Maltha e AM Kuijpers-Jagtman. Optimum force magnitude for orthodontic tooth movement A systematic literature review. Angle Orthodontist, 2003quem mais cita →
- 9CJ Burstone e K Choy. The Biomechanical Foundation of Clinical Orthodontics. 2015quem mais cita →
- 10RF Viecilli, TR Katona, J Chen e mais 2. Three-dimensional mechanical environment of orthodontic tooth movement and root resorption. Am J Orthod Dentofac Orthop, 2008quem mais cita →
- 11MG Faulkner, P Fuchshuber, D Haberstock e mais 1. A parametric study of the force/moment systems produced by T-loop retraction springs. J Biomech, 1989quem mais cita →
- 12RP Martins, PH Buschang, LP Martins e mais 1. Optimizing the design of preactivated titanium T-loop springs with Loop software. Am J Orthod Dentofac Orthop, 2008quem mais cita →
- 13C Manhartsberger, JY Morton e CJ Burstone. Space closure in adult patients using the segmented arch technique. Angle Orthod, 1989quem mais cita →
- 14Z Xia, J Chen, F Jiangc e mais 3. Load system of segmental T-loops for canine retraction. Am J Orthod Dentofac Orthop, 2013quem mais cita →
- 15C Burstone, E Van Steenergen e KJ Hanlev. Modern Edgewise mechanics and the segmented arch technique. 1995quem mais cita →
- 16RF Viecilli. Self-corrective T-loop design for differential space closure. Am J Orthod Dentofac Orthop, 2006quem mais cita →
- 17SGFR Caldas, RP Martins, RF Viecilli e mais 2. Effects of stress relaxation in beta-titanium orthodontic loops I. Am J Orthod Dentofac Orthop, 2011quem mais cita →
- 18KD Hoenigl, J Freudenthaler, MR Marcotte e mais 1. The centered T-loop-A new way of preactivation. Am J Orthod Dentofac Orthop, 1995quem mais cita →
- 19WD Callister Jr. Materials science and engineering: an introduction. Hoboken,. 2006quem mais cita →
- 20RP Martins, PH Buschang, R Viecilli e mais 1. Curvature versus V-bends in a group B titanium T-loop spring. Angle Orthod, 2008quem mais cita →
Quem cita esta obra
2 artigos do acervo
- 2021: citada em 2 artigos
quem fala desta obra
11 pessoas- Jorge ABRÃO1 artigo · 2021
- Rafael Golghetto DOMINGOS1 artigo · 2021
- Jeryl D. ENGLISH1 artigo · 2021
- Ariane S. GONZAGA1 artigo · 2021
- Helder B. JACOB1 artigo · 2021
- Dalva Cruz LAGANÁ1 artigo · 2021
- Erik T. LE1 artigo · 2021
- Almir LIMA JÚNIOR1 artigo · 2021
- João Batista de PAIVA1 artigo · 2021
- José RINO NETO1 artigo · 2021
os artigos
- Stress distribution analysis in anterior teeth caused by several retraction mechanicsRafael Golghetto DOMINGOS e mais 5 · Dental Press Journal of Orthodontics · 2021
- Effects of stress relaxation in beta-titanium cantilevers used in orthodontic mechanicsHelder B. JACOB e mais 4 · Dental Press Journal of Orthodontics · 2021
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda