resumo

ABSTRACT Objective: The aim of the present study was to clarify the biomechanics of en-masse retraction of the upper anterior teeth and attempt to quantify the different forces and moments generated using mini-implants and to calculate the amount of applied force optimal for en-masse intrusion and retraction using mini-implants. Methods: The optimum force required for en-masse intrusion and retraction can be calculated by using simple mathematical formulae. Depending on the position of the mini-implant and the relationship of the attachment to the center of resistance of the anterior segment, different clinical outcomes are encountered. Using certain mathematical formulae, accurate measurements of the magnitude of force and moment generated on the teeth can be calculated for each clinical outcome. Results: Optimum force for en-masse intrusion and retraction of maxillary anterior teeth is 212 grams per side. Force applied at an angle of 5o to 16o from the occlusal plane produce intrusive and retraction force components that are within the physiologic limit. Conclusion: Different clinical outcomes are encountered depending on the position of the mini-implant and the length of the attachment. It is possible to calculate the forces and moments generated for any given magnitude of applied force. The orthodontist can apply the basic biomechanical principles mentioned in this study to calculate the forces and moments for different hypothetical clinical scenarios.

como citar · ABNT NBR 6023

FELICITA, A. Sumathi. Quantification of intrusive/retraction force and moment generated during en-masse retraction of maxillary anterior teeth using mini-implants: A conceptual approach. Dental Press Journal of Orthodontics, 2017. DOI: 10.1590/2177-6709.22.5.047-055.OAR.

Referências

18 obras citadas

  1. 1HS Park, SH Jeong e OW Kwon. Factors affecting the clinical success of screw implants used as orthodontic anchorage. Am J Orthod Dentofacial Orthop, 2006quem mais cita →
  2. 2HM Kyung, HS Park, SM Bae e mais 2. Development of orthodontic micro-implants for intraoral anchorage. J Clin Orthod, 2003quem mais cita →
  3. 3CH Moon, DG Lee, HS Lee e mais 2. Factors associated with the success rate of orthodontic miniscrews placed in the upper and lower posterior buccal region. Angle Orthod, 2008quem mais cita →
  4. 4S Baumgaertel, MR Razavi e MG Hans. Mini-implant anchorage for the orthodontic practitioner. Am J Orthod Dentofacial Orthop, 2008quem mais cita →
  5. 5RJ Herman, GF Currier e A Miyake. Mini-implant anchorage for maxillary canine retraction a pilot study. Am J Orthod Dentofacial Orthop, 2006quem mais cita →
  6. 6KR Chung, G Nelson, SH Kim e mais 1. Severe bidentoalveolar protrusion treated with orthodontic microimplant-dependent en-masse retraction. Am J Orthod Dentofacial Orthop, 2007quem mais cita →
  7. 7JS Garfinkle, LL Cunningham Jr, CS Beeman e mais 3. Evaluation of orthodontic mini-implant anchorage in premolar extraction therapy in adolescents. Am J Orthod Dentofacial Orthop, 2008quem mais cita →
  8. 8WR Proffit e HW Fields. Contemporary orthodontics. 2000quem mais cita →
  9. 9D Gross, W Hauger, J Schröder e mais 3. Engineering Mechanics 1: Statics. 2013quem mais cita →
  10. 10S Reimann, L Keilig, A Jäger e mais 1. Biomechanical finite-element investigation of the position of the centre of resistance of the upper incisors. Eur J Orthod, 2007quem mais cita →
  11. 11E Pedersen, F Isidor, P Gjessing e mais 1. Location of centres of resistance for maxillary anterior teeth measured on human autopsy material. Eur J Orthod, 1991quem mais cita →
  12. 12N Ash. Wheeler's Dental anatomy, physiology and occlusion. 2003quem mais cita →
  13. 13MM Vanden Bulcke, LR Dermaut, RC Sachdeva e mais 1. The center of resistance of anterior teeth during intrusion using the laser reflection technique and holographic interferometry. Am J Orthod Dentofacial Orthop, 1986quem mais cita →
  14. 14MM Vanden Bulcke, CJ Burstone, RC Sachdeva e mais 1. Location of the centers of resistance for anterior teeth during retraction using the laser reflection technique. Am J Orthod Dentofacial Orthop, 1987quem mais cita →
  15. 15K Choy, KH Kim e CJ Burstone. Initial changes of centres of rotation of the anterior segment in response to horizontal forces. Eur J Orthod, 2006quem mais cita →
  16. 16GM Jeong, SJ Sung, KJ Lee e mais 2. Finite element investigation of the center of resistance of the maxillary dentition. Korean J Orthod, 2009quem mais cita →
  17. 17HK Lee e KR Chung. The vertical location of the center of resistance for maxillary six anterior teeth during retraction using three dimensional finite element analysis. Korean J Orthod, 2001quem mais cita →
  18. 18S Sia, Y Koga e N Yoshida. Determining the center of resistance of maxillary anterior teeth subjected to retraction forces in sliding mechanics an in vivo study. Angle Orthod, 2007quem mais cita →

Quem cita esta obra

1 artigo do acervo

quem fala desta obra

2 pessoas

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações