Brazilian Journal of Pharmaceutical Sciences2020
Development and validation of an HPLC-UV method for accelerated stability study and pharmacokinetic analysis of venlafaxine
Muhammad Sher, Maria Ahmad, Faiza Hassan, Muhammad Naeem-ul-Hassan e Muhammad Ajaz Hussain
em inglês
resumo
A reverse phase high performance liquid chromatography method has been developed and validated for accelerated stability study and determination of pharmacokinetic parameters of venlafaxine HCl. The chromatographic separation was carried out using ODS analytical column (250 × 4.6 mm i.d., 5 µm particle size). The mobile phase included acetonitrile, methanol and potassium dihydrogen phosphate buffer (30:30:40; pH 6.1) at a flow rate 1.5 mL min−1. UV-Visible detector was used at wavelength of 227 nm to monitor elutions. Retention time observed was 2.745 min. The method was validated for linearity, accuracy, precision, sensitivity and robustness. Accelerated stability study of venlafaxine HCl capsules was carried out at 40 and 50 ºC under 75% RH level. Suggested method was successfully applied for the pharmacokinetic analysis of venlafaxine hydrochloride tablets. Each of ten albino rabbits (≈ 1.2 kg each) was orally administered with 5 mg dose of venlafaxine HCl. The method was proved to be linear (R2 >0.998), accurate (98.25-99.27%), sensitive (LOD: 35ngmL−1; LOQ: 105 ng mL−1) and robust (RSD<1%). The drug showed stability at accelerated conditions of temperature and humidity. The main pharmacokinetic parameters of tested products were as follows: tmax was 2.5h, Cmax was 56.5 µg mL−1, t1/2 was 8.2 h, AUC0-36 was 845.9 µg h mL−1. The developed method is suitable to apply for quality control analysis and pharmacokinetic studies.
como citar · ABNT NBR 6023
SHER, Muhammad et al. Development and validation of an HPLC-UV method for accelerated stability study and pharmacokinetic analysis of venlafaxine. Brazilian Journal of Pharmaceutical Sciences, 2020. DOI: 10.1590/S2175-97902019000217728.
Referências
23 obras citadas
- 1EB Asafu-Adjaye, PJ Faustino, MA Tawakkul e mais 3. Validation and application of a stability indicating HPLC method for the in vitro determination of gastric and intestinal stability of venlafaxine. J Pharm Biomed Anal, 2007quem mais cita →
- 2SL Baldania, KK Bhatt, RS Mehta e mais 2. RPHPLC estimation of venlafaxine hydrochloride in tablet dosage forms. Indian J Pharm Sci, 2008quem mais cita →
- 3LS Bernardi, PR Oliveira, FS Murakami e mais 3. Development and validation of a stability-indicating LC method for the determination of venlafaxine in extended-release capsules and dissolution kinetic studies. J Chromatogr. Sci., 2009quem mais cita →
- 4J Bhatt, A Jangid, G Venkatesh e mais 2. Liquid chromatography-tandem mass spectrometry (LC-MS-MS) method for simultaneous determination of venlafaxine and its active metabolite O-desmethyl venlafaxine in human plasma. J Chromatogr B, 2005quem mais cita →
- 5CC Chan, YC Lee, H Lam e mais 1. Analytical method validation and instrument performance verification. 2004quem mais cita →
- 6Z Chen, H Meng, G Xing e mais 3. Acute toxicological effects of copper nanoparticles in vivo. Toxicol Lett, 2006quem mais cita →
- 7UK Chhalotiya, HB Patel e KK Bhatt. Development and validation of an ultra-performance liquid chromatography method for venlafaxine hydrochloride in bulk and capsule dosage form. Indian J Pharm Sci, 2010quem mais cita →
- 8KE Goeringer, IM McIntyre e OH Drummer. Postmortem tissue concentrations of venlafaxine. Forensic Sci Int, 2001quem mais cita →
- 9S Gursharanjit, B Ghosh e D Dave. Screening of venlafaxine hydrochloride for delivery. AAPS Pharm SciTech, 2008quem mais cita →
- 10ICH e HTG. International Conference on Harmonisation; Guideline on Validation of Analytical Procedures: Definitions and Terminology Availability. Part VIII. Federal Register. 1996quem mais cita →
- 11ICH Validation of analytical procedures: text and methodology. 2005quem mais cita →
- 12H Juan, Z Zhiling e L Huande. Simultaneous determination of fluoxetine, citalopram, paroxetine, venlafaxine in plasma by high performance liquid chromatography-electrospray ionization mass spectrometry (HPLC-MS/ESI). J Chromatogr B, 2005quem mais cita →
- 13J Kaur, KK Srinivasan, A Joseph e mais 3. Development and validation of stability indicating method for the quantitative determination of venlafaxine hydrochloride in extended release formulation using high performance liquid chromatography. J Pharm Bioallied Sci, 2010quem mais cita →
- 14W Liu, YC Dai, N Deng e mais 2. Development and validation of a HPLC-MS/MS method for the determination of venlafaxine enantiomers and application to a pharmacokinetic study in healthy Chinese volunteers. Biomed Chrom, 2011quem mais cita →
- 15SN Makhija e PR Vavia. Stability indicating LC method for the estimation of venlafaxine in pharmaceutical formulations. J Pharm Biomed Anal, 2002quem mais cita →
- 16PB Parejiya, VR Movaliya, BS Barot e mais 3. Quantitative determination of milnacipran HCl in rabbit plasma by HPLC and its application to pharmacokinetics study. J Liq Chromatogr Relat Technol, 2014quem mais cita →
- 17S Rudaz, C Stella, AE Balant-Gorgia e mais 2. Simultaneous stereoselective analysis of venlafaxine and O-desmethylvenlafaxine enantiomers in clinical samples by capillary electrophoresis using charged cyclodextrins. J Pharm Biomed Anal, 2000quem mais cita →
- 18MC Sánchez-Mata, M Cámara-Hurtado, C Díez-Marqués e mais 1. Comparison of high-performance liquid chromatography and spectrofluorimetry for vitamin C analysis of green beans (Phaseolus vulgaris L.). Eur Food Res Technol, 2000quem mais cita →
- 19VC Seshadri, PJ Manohari e J Kunchithapatham. Formulation and characterization of mouth dissolving tablets containing benzodiazepine. Indo Am J Pharm Res, 2013quem mais cita →
- 20K Titier, N Castaing, E Scotto-Gomez e mais 3. High performance liquid chromatographic method with diode array detection for identification and quantification of the eight new antidepressants and five of their active metabolites in plasma after overdose. Ther Drug Monit, 2003quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda