Brazilian Journal of Pharmaceutical Sciences2017
Development and validation of stability indicating liquid chromatographic (RP-HPLC) method for estimation of ubidecarenone in bulk drug and formulations using quality by design (QBD) approach
Abdul Muheem, Faiyaz Shakeel, Sobiya Zafar, Mohammed Asadullah Jahangir, Musarrat Husain Warsi, Gaurav Kumar Jain e Farhan Jalees Ahmad
em inglês
resumo
ABSTRACT A novel, accurate, precise and economical stability indicating Reverse Phase-High Performance Liquid Chromatography (RP-HPLC) method, was developed and validated for the quantitative determination of ubidecarenone (UDC) in bulk drug, UDC marketed formulation and UDC loaded cubosomes (CBMs) nanocarriers through Response surface methodology (RSM) design with three factors and three levels was performed to optimize the chromatographic variables followed by forced degradation studies of UDC were performed to detect degradation peak. RP-HPLC separation was achieved using mobile phase consisting of Acetonitrile:Tetrahydrofuran:Deionised water in the ratio 55:42:3 and a flow rate of 1.0 mL/min was optimized with a standard retention time (Rt) of 2.15 min, through experiment. The method was found linear in the concentration range of 5-100 µg/mL with a regression coefficient of 0.999. The limit of detection (LOD) and limit of quantification (LOQ) were found to be 3.04 µg/mL and 9.11 µg/mL, respectively.
como citar · ABNT NBR 6023
MUHEEM, Abdul et al. Development and validation of stability indicating liquid chromatographic (RP-HPLC) method for estimation of ubidecarenone in bulk drug and formulations using quality by design (QBD) approach. Brazilian Journal of Pharmaceutical Sciences, 2017. DOI: 10.1590/S2175-97902017000417293.
Referências
19 obras citadas
- 1MS Abdel-Kader, P Alam e SI Alqasoumi. Densitometric HPTLC method for qualitative, quantitative analysis and stability study of coenzyme Q10 in Pharmaceutical formulations utilizing normal and reversed-phase silica gel plates. Pak J Pharm Sci, 2016quem mais cita →
- 2S Beg, K Kohli, S Swain e mais 1. Development and validation of RP-HPLC method for quantitation of amoxicillin trihydrate in bulk and pharmaceutical formulations using Box-Behnken experimental design. J Liq Chromatogr Relat Technol, 2012quem mais cita →
- 3GE Box e DW Behnken. Some new three level designs for the study of quantitative variables. Technomet, 1960quem mais cita →
- 4L Ernster e G Dallne. Biochemical, physiological and medical aspects of ubiquinone function. Biochim Biophys Acta (BBA)-Mol Basis Dis, 1995quem mais cita →
- 5N Flowers, L Hartley e K Rees. Co-enzyme Q10 supplementation for the primary pre-vention of cardiovascular disease. Cochrane Database Syst Rev, 2013quem mais cita →
- 6S Graves, M Sikorska, H Borowy-Borowski e mais 3. Analysis of coenzyme Q 10 content in human plasma and other biological samples. Meth Mol Bio, 1998quem mais cita →
- 7S Greenberg e WHJ Frishman. Co-enzyme Q10 a new drug for cardiovascular disease. J Clin Pharmacol, 1990quem mais cita →
- 8G Hansen, P Christensen, E Tüchsen e mais 1. Sensitive and selective analysis of coenzyme Q 10 in human serum by negative APCI LC-MS. Analyst, 2004quem mais cita →
- 9MS Hasnain, S Rao, MK Singh e mais 6. Development and validation of LC-MS/MS method for the quantitation of lenalidomide in human plasma using Box-Behnken experimental design. Analyst, 2013quem mais cita →
- 10K Hosoe, M Kitano, H Kishida e mais 3. Study on safety and bioavailability of ubiquinol (Kaneka QH(tm)) after single and 4-week multiple oral administration to healthy volunteers. Regul Toxicol Pharmacol, 2007quem mais cita →
- 11International Conference on Harmonisation. Guideline. ICH. Validation of analytical procedures: text and methodology. Q2 (R1). 2005quem mais cita →
- 12P Kapoor e A Kapoor. Coenzyme Q10-A novel molecule. J Ind Acad Clin Med, 2013quem mais cita →
- 13JK Lang e L Packer. Quantitative determination of vitamin E and oxidized and reduced coenzyme Q by high-performance liquid chromatography with in-line ultraviolet and electrochemical detection. J Chrom A, 1987quem mais cita →
- 14S Lunetta e M Roman. Determination of coenzyme Q10 content in raw materials and dietary supplements by high-performance liquid chromatography-UV collaborative study. J AOAC Int, 2008quem mais cita →
- 15MV Miles. The uptake and distribution of coenzyme Q (10). Mitochondrion, 2007quem mais cita →
- 16A Muheem, F Shakeel, MH Warsi e mais 2. A combinatorial statistical design approach to optimize the nanostructured cubosomal carrier system for oral delivery of ubidecarenone for management of doxorubicin induced cardiotoxicity In Vitro-In Vivo investigations. J Pharm Sci, 2017quem mais cita →
- 17PT Spicer, KL Hayden, ML Lynch e mais 2. Novel process for producing cubic liquid crystalline nanoparticles (cubosomes). Langmuir, 2001quem mais cita →
- 18MT Tran, TM Mitchell, DT Kennedy e mais 1. Role of coenzyme Q10 in chronic heart failure, angina, and hypertension. Pharmacother J Human Pharmacol Drug Ther, 2001quem mais cita →
- 19S Vadhanavikit, N Sakamoto, N Ashida e mais 2. Quantitative determination of coenzyme Q10 in human blood for clinical studies. Anal Biochem, 1984quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda