Brazilian Journal of Pharmaceutical Sciences2011
Antibiotic microbial assay using kinetic-reading microplate system
Felipe Rebello Lourenço e Terezinha de Jesus Andreoli Pinto
em inglês
citado por 1 artigocita 51 obras, 1 no acervo
resumo
The aim of this study was to determine the optimal experimental conditions to develop a methodology for microbiological assay of apramycin employing microplate and kinetic reading mode, and to validate the developed method, through evaluation of parameters of selectivity, linearity, linear range, limits of detection and quantification, accuracy and precision. The turbidimetric assay principle is simple: the test solution is added to a suspension of test microorganism in culture media, the mixture is incubated under appropriate conditions and the microbial growth is measured by photometric reading. Microplate with kinetic reading mode employed in antibiotic assay is of considerable interest since it allows reduction of material and analysis time and enables a large number of samples to be analyzed simultaneously, with automated reading and calculating. Established conditions considered the standard-curve of apramycin at concentrations from 5.0 to 35.0 μg mL-1, and tryptic soy broth inoculated with 5% Escherichia coli (ATCC 8739) suspension. Satisfactory results were obtained with 2 hours of incubation. The developed method showed appropriate selectivity, linearity in the range from 5.0 to 35.0 μg mL-1, limits of detection and quantification of 0.1 and 0.4 μg mL-1, respectively, as well as satisfactory accuracy (recuperation = 98.5%) and precision (RSD = 6.0%). Microplate assay combined the characteristics of microbiological (evaluation of antibiotic activity against sensitive test microorganism) and physico-chemical (operationally straightforward and faster results) assays.
como citar · ABNT NBR 6023
LOURENÇO, Felipe Rebello; PINTO, Terezinha de Jesus Andreoli. Antibiotic microbial assay using kinetic-reading microplate system. Brazilian Journal of Pharmaceutical Sciences, 2011. Disponível em: https://www.scielo.br/scielo.php?script=sci_arttext&pid=S1984-82502011000300015. Acesso em: 28 nov. 2026.
Referências
51 obras citadas · 1 no acervo
- 1H. BAMBA. Assay for susceptibility of Helicobacter pylori to antibiotics using 96-well flat-bottom microplate and microplate reader. Rinsho Kensa, 1997quem mais cita →
- 2E.A.B. ANTUNES, F.R. LOURENÇO e T.J.A. PINTO. Determination of apramycin in oral soluble powder by a HPLC method using pre-column derivatization with o-phthalaldehyde and UV detection. Braz. J. Pharm. Sci., 2011no acervo →
- 3J.M. BARRET. Evaluation of DNA repair inhibition by antitumor or antibiotic drugs using a chemiluminescence microplate assay. Carcinogenesis, 1997quem mais cita →
- 4S. BOGIALLI, R. CURINI, A. CORCIA e mais 3. Simple confirmatory assay for analyzing residues of aminoglycoside antibiotics in bovine milk: hot water extraction followed by liquid chromatography-tandem mass spectrometry. J. Chromatogr. A, 2005quem mais cita →
- 5C.R. BOND e O.L. DAVIES. The microbiological assay of penicillin by the turbidimetric method, using Staphylococcus aureus. Analyst, 1948quem mais cita →
- 6P.R. BONTCHEV, P. PAPAZOVA, M. CONFINO e mais 1. Spectrophotometric method for determination of tobramycin, apramycin and kanamycin in formulations. Mikrochim. Acta, 1984quem mais cita →
- 7V. BORISEVICH. A highly sensitive and versatile vírus titration assay in the 96-well microplate format. J. Virol. Methods, 2008quem mais cita →
- 8M.S. BRADY e S.E. KATZ. Turbidimetric assay for tetracyclines in feeds using a microtiter plate system. J. Assoc. Off. Anal. Chem., 1991quem mais cita →
- 10E. BURTON. A microplate spectrofluorimetric assay for bacterial biofilms. J. Ind. Microbiol. Biotechnol., 2007quem mais cita →
- 11K.E. COOPER. The theory of antibiotic inhibition zones. Analytical microbiology, 1963quem mais cita →
- 12C.R. FALK. Adaptation of antibiotic assay methods for routine use. Am. J. Public Health, 1953quem mais cita →
- 13J. FIELDING. A simple method of estimating penicillin and other bacteriostatics. Br. Med. J., 1947quem mais cita →
- 14A. FLEMING. Micromethods of estimating penicillin in blood serum. Lancet, 1944quem mais cita →
- 15A. FLEMING. Estimation of penicillin in serum use of glucose, phenol red, and serum water. Lancet, 1947quem mais cita →
- 16J.W. FOSTER e H.B. WOODRUFF. Microbiological aspects of penicillin: I. Methods of assay. J. Bacteriol., 1943quem mais cita →
- 17T. HERMANN, V. TERESHKO, E. SKRIPKIN e mais 1. Apramycin recognition by human ribosomal decoding site. Blood Cells Mol. Dis., 2007quem mais cita →
- 18W. HEWITT. Microbiological assay: an introduction to quantitative principles and evaluation. 1977quem mais cita →
- 19S.A. HOLOWACHUK. A kinetic microplate method for quantifying the antibacterial properties of biological fluids. J. Microbiol. Methods, 2003quem mais cita →
- 20N. ISOHERRANEN e S. SOBACK. Chromatographic Methods for Analysis of Aminoglycoside Antibiotics. J. AOAC Int., 1999quem mais cita →
- 21D.A. JOSLYN. Penicillin assay: Outline of four-hour turbidimetric method. Science, 1944quem mais cita →
Quem cita esta obra
1 artigo do acervo
quem fala desta obra
7 pessoas- Giselle de Carvalho1 artigo · 2018
- Priscila Santos Casado1 artigo · 2018
- Vanina Lilian Castroagudín1 artigo · 2018
- Paulo Cezar Ceresini1 artigo · 2018
- João Leodato Nunes Maciel1 artigo · 2018
- Omar Jorge Sabbag1 artigo · 2018
- Samara Nunes Campos Vicentini1 artigo · 2018