Pesquisa Brasileira em Odontopediatria e Clínica Integrada2021

Direct and Indirect Bonding Techniques: A Systematic Review

Paolo Albertini, Laura Mele, Mario Palone e Francesca Cremonini

em inglês

cita 42 obras, 1 no acervo

resumo

ABSTRACT Objective: To assess the scientific evidence on direct and indirect bonding techniques to analyse the differences related to treatment time, number of appointments and number of bracket detachments. Material and Methods: The MEDLINE and Cochrane Library databases were searched through to March 2021. Reference lists from the retrieved publications were also examined. The following article types that described data on the different types of direct and indirect bonding techniques in orthodontics were included: prospective and retrospective cohort studies, case-control studies and randomized controlled clinical trials (RCCTs). Two review authors independently assessed eligibility, extracted data, and ascertained the quality of the studies. Results: The search strategy initially resulted in 824 articles, and after a careful selection comprising the inclusion criteria, 12 articles were picked for the final review, specifically 2 cohort studies, 4 case-control studies and 6 RCCTs. The methodological quality was low in 4 studies, medium in 2, and high in 6 articles. Conclusion: The evidence currently available suggests that the use of computer-aided bonding is related to a reduction in treatment time and the number of appointments compared to direct and manual indirect bonding. However, the total bonding time for computer-aided bonding technique, including digital bracket placement, was longer than for direct bonding. Further high-quality RCTs on the differences between direct and indirect bonding are necessary to determine more precise data, as well as additional advantages and disadvantages.

como citar · ABNT NBR 6023

ALBERTINI, Paolo et al. Direct and Indirect Bonding Techniques: A Systematic Review. Pesquisa Brasileira em Odontopediatria e Clínica Integrada, 2021. DOI: 10.1590/PBOCI.2021.137.

Referências

42 obras citadas · 1 no acervo

  1. 1GV Newman. Epoxy adhesives for orthodontic attachments: progress report. Am J Orthod, 1965quem mais cita →
  2. 2E Silverman, M Cohen, AA Gianelly e mais 1. A universal direct bonding system for both metal and plastic brackets. Am J Orthod, 1972quem mais cita →
  3. 3RA Hocevar. Direct bonding metal brackets with concise - enamel bond system. J Clin Orthod, 1977quem mais cita →
  4. 4RA Hocevar. Direct bonding update. J Clin Orthod, 1979quem mais cita →
  5. 5RG Thomas. Indirect bonding: simplicity in action. J Clin Orthod, 1979quem mais cita →
  6. 6MJ Read. Indirect bonding using a visible light cured adhesive. Br J Orthod, 1987quem mais cita →
  7. 7A Sondhi. Efficient and effective indirect bonding. Am J Orthod Dentofacial Orthop, 1999quem mais cita →
  8. 8L Pisani, L Bonaccorso, R Fastuca e mais 3. Systematic review for orthodontic and orthopedic treatments for anterior open bite in the mixed dentition. Prog Orthod, 2016quem mais cita →
  9. 9SK Carlson e E Johnson. Bracket positioning and resets: five steps to align crowns and roots consistently. Am J Orthod Dentofacial Orthop, 2001quem mais cita →
  10. 10RP McLaughlin e JC Bennett. Bracket placement with the preadjusted appliance. J Clin Orthod, 1995quem mais cita →
  11. 11A Arreghini, L Lombardo, F Mollica e mais 1. Torque expression capacity of 0.018 and 0.022 bracket slots by changing archwire material and cross section. Prog Orthod, 2014quem mais cita →
  12. 12L Lombardo, G Toni, F Stefanoni e mais 3. The effect of temperature on the mechanical behavior of nickel-titanium orthodontic initial archwires. Angle Orthod, 2013quem mais cita →
  13. 13MA Lopez, M Andreasi Bassi, L Confalone e mais 3. The influence of conical plus octagonal internal connection on implant survival and success rate: a retrospective study of 66 fixtures. J Biol Regul Homeost Agents, 2016quem mais cita →
  14. 14MA Lopez, M Andreasi Bassi, L Confalone e mais 3. Retrospective study on bone-level and soft-tissue-level cylindrical implants. J Biol Regul Homeost Agents, 2016quem mais cita →
  15. 15MA Lopez, M Andreasi Bassi, L Confalone e mais 3. Clinical outcome of 215 transmucosal implants with a conical connection: a retrospective study after 5-year follow-up. J Biol Regul Homeost Agents, 2016quem mais cita →
  16. 16D Manfredini, E Stellini, A Gracco e mais 3. Orthodontics is temporomandibular disorder-neutral. Angle Orthod, 2016quem mais cita →
  17. 17L Lombardo, F Carinci, M Martini e mais 3. Quantitive evaluation of dentin sialoprotein (DSP) using microbeads - a potential early marker of root resorption. Oral Implantol, 2016quem mais cita →
  18. 18F Perrini, L Lombardo, A Arreghini e mais 2. Caries prevention during orthodontic treatment: In-vivo assessment of high-fluoride varnish to prevent white spot lesions. Am J Orthod Dentofacial Orthop, 2016quem mais cita →
  19. 19A Arreghini, S Trigila, L Lombardo e mais 1. Objective assessment of compliance with intra- and extraoral removable appliances. Angle Orthod, 2017quem mais cita →
  20. 20I Czolgosz, PM Cattaneo e MA Cornelis. Computer-aided indirect bonding versus traditional direct bonding of orthodontic brackets: bonding time, immediate bonding failures, and cost-minimization. A randomized controlled trial. Eur J Orthod, 2021quem mais cita →
1–20 de 42 obras citadas

Quem cita esta obra

nenhum artigo do acervo cita esta obra — ainda

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações