RGO - Revista Gaúcha de Odontologia2014
Surface treatment of implants: primary stability
Nathalia Ferraz OLISCOVICZ, Ronaldo José da SILVA, César Penazzo LEPRI, Élcio MARCANTONIO JUNIOR e Andréa Cândido dos REIS
em inglês
resumo
OBJECTIVE: The aim of this study was to analyze the primary stability of dental implants with and without surface treatment, by means of resonance frequency, using different materials as substitutes for human bone substrates for insertion. METHODS: Sixteen external hexagon, cylindrical Conexão(r) titanium implants were used, 11.5 mm long by 3.75 mm wide, as follows: 8 Master Porous (MP), with surface treatment and 8 Master Screw (MS) machined. The implant placement was performed on the following substrates: pork rib bone, wood, artificial bone polyurethane National(r) (40, 20, 15 PCF) and Synbone(r). Primary stability was assessed via resonance frequency using an Osstell Mentor(tm) device. Data were analyzed statistically using ANOVA and Tukey's test, with a significance level of 5%. RESULTS: It was found that although MP and MS have a higher value on all substrates, these were not statistically different between groups (p>0.05), except for polyurethane National(r) 20 PCF. When inserted into the wood substrate and polyurethane National(r) 40 PCF, MP and MS had higher values. MP, when inserted into the pig bone, was also statistically equal to these interactions. CONCLUSION: Despite the continuous development of innovations in the characteristics of implant surfaces to assist with the performance of osseointegrated implants, and the fact that our study has found that the surface treatment had no impact on the primary stability checked using ressonance frequency, there is still very little scientific understanding of these effects.
como citar · ABNT NBR 6023
OLISCOVICZ, Nathalia Ferraz et al. Surface treatment of implants: primary stability. RGO - Revista Gaúcha de Odontologia, 2014. DOI: 10.1590/1981-8637201400040000012580.
Referências
31 obras citadas
- 1U Aksoy, K Eratalay e TF Tözüm. The possible association among bone density values, resonance frequency measurements, tactile sense, and histomorphometric evaluations of dental implant osteotomy sites: a preliminary study. Implant Dent, 2009quem mais cita →
- 2JEIG Brouwers, F Lobbezoo, CM Visscher e mais 2. Reliability and validity of the instrumental assessment of implant stability in dry human mandibles. J Oral Rehab, 2009quem mais cita →
- 3J Rozé, S Babu, A Saffarzadeh e mais 3. Correlating implant stability to bone structure. Clin Oral Impl Res, 2009quem mais cita →
- 4I Turkyilmaz, TF Tözüm, C Tumer e mais 1. Assessment of correlation between computerized tomography values of the bone, and maximum torque and resonance frequency values at dental implant placement. J Oral Rehabil, 2006quem mais cita →
- 5YD1 Song, SH Jun e JJ Kwon. Correlation between bone quality evaluated by cone-beam computerized tomography and implant primary stability. Int J Oral Maxillofac Implants, 2009quem mais cita →
- 6MC Cehreli, AM Kökat, A Comert e mais 3. Implant stability and bone density: assessment of correlation in fresh cadavers using conventional and osteotome implant sockets. Clin Oral Impl Res, 2009quem mais cita →
- 7M Degidi, G Daprile e A Piattelli. Determination of primary stability: a comparison of the surgeon's perception and objective measurements. Int J Oral Maxillofac Implants, 2010quem mais cita →
- 8S Kahraman, BT Bal, NV Asar e mais 2. Clinical study on the insertion torque and wireless resonance frequency analysis in the assessment of torque capacity and stability of self-tapping dental implants. J Oral Rehabil, 2009quem mais cita →
- 9L Chong, A Khocht, JB Suzuki e mais 1. Effect of implant design on initial stability of tapered implants. J Oral Implant, 2009quem mais cita →
- 10PL Rao e A Gill. Primary stability: the password of implant integration. J Dental Impl, 2012quem mais cita →
- 11VV Kumar, K Sagheb, MO Klein e mais 3. Relation between bone quality values from ultrasound transmission velocity and implant stability parameters - an ex vivo study. Clin Oral Implants Res, 2012quem mais cita →
- 12K Ohta, M Takechi, M Minami e mais 3. Influence of factors related to implant stability detected by wireless resonance frequency analysis device. J Oral Rehab, 2010quem mais cita →
- 13M Boronat López, O Peñarrocha Diago, I Martínez Cortissoz e mais 1. Resonance frequency analysis after the placement of 133 dental implants. Med Oral Patol Oral Cir Bucal, 2006quem mais cita →
- 14E Nkenke, M Hahn, K Weinzierl e mais 3. Implant stability and histomorphometry: a correlation study in human cadavers using stepped cylinder implants. Clin Oral Impl Res, 2003quem mais cita →
- 15L Cristofolini, M Viceconti, A Cappello e mais 1. Mechanical validation of whole bone composite femur models. J Biomechanics, 1996quem mais cita →
- 16D1 Buser, T Nydegger, HP Hirt e mais 2. Removal torque values of titanium implants in the maxilla of miniature pigs. Int J Oral Maxillofac Implants, 1998quem mais cita →
- 17CE Misch. Prótese sobre implantes. 2007quem mais cita →
- 18IP Jankowsky, JP Chimelo, A Cavancante e mais 2. Madeiras brasileiras. 1990quem mais cita →
- 19A Tabassum, GJ Meijer, JG Wolke e mais 1. Influence of surgical technique and surface roughness on the primary stability of an implant in artificial bone with different cortical thickness: a laboratory study. Clin Oral Implants Res, 2010quem mais cita →
- 20W Pfeil e M Pfeil. Estruturas de madeira. 2003quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda