RGO - Revista Gaúcha de Odontologia2014
Different materials and techniques for accurate molding for adaptation in angled implants
Lisliane Nara Rossi LEANDRO, Rui Barbosa de BRITO JÚNIOR, Marcelo Lucchesi TEIXEIRA, Luiz Martins TURANO e Luciana Jardini da CUNHA
em inglês
resumo
OBJECTIVE: To evaluate the marginal misfit between intermediate and micro-unitmetal cylinder, by varying the angle of the implants, using two different types of material and different molding techniques. METHODS: A model was made with three implants (one perpendicular to the horizontal plane and two inclined) using micro-unit intermediates. A rod attached to the master model served as a control condition to evaluate the suitability of the twenty specimens, carried out with the help of an optical stereomicroscope (Pantec, Brazil; Materials Testing Laboratory, São Leopoldo Mandic, Campinas, São Paulo). RESULTS: Evaluator reliability was assessed using theIntraclass Correlation Coefficient, obtaining 99.6% (excellent). There were significant differences between groups, and the Mann-Whitney test compared groups in pairs for a more accurate result. CONCLUSION: The group which presented the best behavior was open tray and condensation silicone and the worst result, that needed to be cast several times, was closed tray and condensation silicone.
como citar · ABNT NBR 6023
LEANDRO, Lisliane Nara Rossi et al. Different materials and techniques for accurate molding for adaptation in angled implants. RGO - Revista Gaúcha de Odontologia, 2014. DOI: 10.1590/1981-8637201400020000072608.
Referências
16 obras citadas · 1 no acervo
- 1T Jemt e K Book. Prosthesis misfit and marginal bone loss in edentulous implant patients. Int J Oral Maxillofac Implants, 1996quem mais cita →
- 2T Jemt e A Lie. Accuracy of implant-supported prostheses in edentulous jaw. Clin Oral Implants Res., 1995quem mais cita →
- 3T Kallus e C Bressing. Loose gold screws frequently occur in full fixed prostheses supported by osseointegrated implants after 5 years. Int J Oral Maxillofac Implants, 1994quem mais cita →
- 4PI Branemark. Osseointegration and its experimental background. J Prosthet Dent, 1983quem mais cita →
- 5G Burawi, F Houston, D Byrne e mais 1. A comparison of the dimensional accuracy of the splinted and unsplinted impression techniques for the Bone-Lock implant system. J Prosthet Dent, 1997quem mais cita →
- 6JE De La Cruz, PD Funkenbusch, C Ercoli e mais 3. Verification jig for implant-supported prostheses: a comparison of standard impressions with verification jigs made of different materials. J Prosthet Dent., 2002quem mais cita →
- 7EA Gomes, WG Assunção, OS Costa e mais 2. Moldagem de transferência de prótese sobre implante ao alcance do clínico-geral. Pesq Bras Odontoped Clin Integr, 2006quem mais cita →
- 8JCB Faria, LR Silva-Concilio, ACC Neves e mais 2. Evaluation of the accuracy of different transfer impression techniques for multiple implants. Braz Oral Res, 2011no acervo →
- 9WG Assunção, H Gennari Filho e O Zaniquelli. Evaluation of transfer impressions for osseointegrated implants at various angulations. Implant Dent, 2004quem mais cita →
- 10FD Neves, MRS Oliveira, AJ Fernandes Neto e mais 1. Seleção de intermediários para implantes Bränemark compatíveis. Parte I: casos de implantes múltiplos. BCI, 2000quem mais cita →
- 11MR Spector, TE Donovan e JI Nicholls. An evaluation of impression techniques for osseointegrated implants. J Prosthet Dent, 1990quem mais cita →
- 12RM Humphries, P Yaman e TJ Bloem. The accuary of implant master casts constructed from transfer impressions. Int J Oral Maxillofac Implants, 1990quem mais cita →
- 13CC Hsu, PL Millstein e RS Stein. A comparative analysis of the accuracy of implant transfer techniques. J Prosthet Dent, 1993quem mais cita →
- 14JHN Pinto, AL Valle, JM Scolaro e mais 2. Estudo comparativo entre técnicas de moldagens para implantes odontológicos. Rev Fac Odontol Bauru, 2001quem mais cita →
- 15MC Goiato, SS Domitti e S Consani. Influência dos materiais de moldagem e técnicas de transferência em implante, na precisão dimensional dos modelos de gesso. JBC J Bras Odontol Clín, 1998quem mais cita →
- 16D Herbst, JC Nel, CH Driessen e mais 1. Evaluation of impression accuracy for osseointegrated implant supported superstructures. J Prosthet Dent, 2000quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda