RGO - Revista Gaúcha de Odontologia2014
Parameters that influence microtensile bond testing of adhesive systems
Estevam Carlos de Oliveira LULA, Taissa Helena Martins LEITE, Cláudia Maria Coelho ALVES, Ivone Lima SANTANA, Ana Maria Lima ALMEIDA e José Ferreira COSTA
comunicação breve · em inglês
resumo
The aim of this study was to provide a critical review of the literature regarding factors that can interfere with microtensile test results for enamel and dentin adhesive systems. Primarily, reports in English, Spanish, or Portuguese that were published between July 1994 and September 2009 and are catalogued in MEDLINE and BBO were used. Additionally, we compiled relevant articles found in the references of these articles and dissertations and theses available in electronic databases of Brazilian universities that examined factors that can influence implementation of the microtensile test at each stage. The search strategy included searching for the following key term groups: microtensile and test; microtensile and assay; microtensile and test and parameters; microtensile and test and factors; microtensile and specimen; microtraccón and especimen. We reviewed 25 selected articles and found that they showed that even after adjustment of test parameters, changes found in the dentin could be responsible for variations observed amongst results. This influence could potentially be reduced by using the cohesive strength value of dentin adjacent to the adhesive interface as a standard for comparison, but more studies are needed to confirm whether such an approach would be reliable. Data analysis methodology should be taken into account when comparing studies.
como citar · ABNT NBR 6023
LULA, Estevam Carlos de Oliveira et al. Parameters that influence microtensile bond testing of adhesive systems. RGO - Revista Gaúcha de Odontologia, 2014. DOI: 10.1590/1981-86372014000100000101620.
Referências
40 obras citadas · 2 no acervo
- 1B van Meerbeek, J Perdigão, P Lambrechts e mais 1. The clinical performance of adhesives. J Dent, 1998quem mais cita →
- 2K Leinfelder. Advances in biorestorative materials: what does the future hold?. J Am Dent Assoc, 2000quem mais cita →
- 3G Eliades. Clinical relevance of the formulation and testing of dentine bonding systems. J Dent, 1994quem mais cita →
- 4CS Fowler, ML Swartz, BK Moore e mais 1. Influence of selected variables on adhesion testing. Dent Mater, 1992quem mais cita →
- 5FT Sadek, C Goracci, F Monticelli e mais 2. Influência da geometria dos espécimes em dentina e esmalte no teste de microtração: análise da resistência de união e microscopia eletrônica de varredura. Rev Ibero-am Odontol Estet Dent, 2004quem mais cita →
- 6JBC Meira, RY Ballester, RG Lima e mais 2. Geometrical aspects on bi-material microtensile tests. J Braz Soc of Mech Sci & Eng, 2005no acervo →
- 7H Sano, T Shono, H Sonoda e mais 3. Relationship between surface area for adhesion and tensile bond strength - evaluation of a micro-tensile bond test. Dent Mater, 1994quem mais cita →
- 8C Goracci. A study on the laboratory techniques for interfacial strength testing of dental materials. 2004quem mais cita →
- 9Y Shono, T Ogawa, M Terashita e mais 3. Regional measurement of resin-dentin bonding as an array. J Dent Res, 1999quem mais cita →
- 10G Leloup, W D'Hoore, D Bouter e mais 2. Meta-analytical review of factors involved in dentin adherence. J Dent Res, 2001quem mais cita →
- 11J Bianchi. Estudo sobre a resistência à microtração em função das dimensões, modo de preensão e formato do corpo-de-prova. 1999quem mais cita →
- 12N Betamar, G Cardew e R van Noort. Influence of specimen designs on the microtensile bond strength to dentin. J Adhes Dent, 2007quem mais cita →
- 13N Betamar, G Cardew e R van Noort. The effect of variations in hourglass, specimen design on microtensile bond strength to dentin. J Adhes Dent, 2007quem mais cita →
- 14KK Chen, Y Shono, T Ogawa e mais 2. Fracture aspects of resin-dentin bonding in non-trimming microtensile test. Dent Mater J, 2001quem mais cita →
- 15AA El Zohairy, AJ Gee, N Jager e mais 2. The influence of specimen attachment and dimension on microtensile strength. J Dent Res, 2004quem mais cita →
- 16E Gassemieh. Evaluation of sources of uncertainties in microtensile bond strength of dental adhesive system for different specimen geometries. Dent Mater, 2008quem mais cita →
- 17C Goracci, FT Sadek, F Monticelli e mais 2. Influence of substrate, shape, and thickness on microtensile specimen´s structural integrity and their measured bond strengths. Dent Mater, 2004quem mais cita →
- 18JC de la Macorra e A San-Nicolás. Method to compare µ-tensile bond strength of a self-etching adhesive and µ-coesive strength of adjacent dentin. Dent Mater, 2005quem mais cita →
- 19A Poitevin, J De Munck, K van Landuyt e mais 3. Critical analysis of the influence of different parameters on the microtensile bond strength of adhesives to dentin. J Adhes Dent, 2008quem mais cita →
- 20S Phrukkanon, MF Burrow e MJ Tyas. The influence of cross-sectional shape and surface area on the microtensile bond test. Dent Mater, 1998quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda