Revista Brasileira de Cineantropometria & Desempenho Humano2016

Agreement analysis between critical power and intensity corresponding to 50% ∆ in cycling exercise

Kristopher Mendes de Souza, Ricardo Dantas de Lucas, Paulo Cesar do Nascimento Salvador, Lucas Crescenti Abdalla Saad Helal, Luiz Guilherme Antonacci Guglielmo, Camila Coelho Greco e Benedito Sérgio Denadai

em inglês

citado por 1 artigocita 30 obras

resumo

Abstract The purpose of this study was to determine the level of agreement between critical power (CP) and intensity corresponding to 50% of the difference (50% ∆) between oxygen uptake (VO2) at lactate threshold (LT) and maximal oxygen uptake (VO2max) in untrained subjects during cycling exercise. Fifteen healthy male subjects (age: 26.0 ± 3.5 years; body weight: 76.6 ± 10.4 kg; height: 178.2 ± 7.6 cm) volunteered to participate in the study. Each subject performed a series of tests to determine LT, VO2LT, CP, VO2CP, 50% ∆, VO250% ∆, and VO2max. The values LT, CP, VO2CP, 50% ∆, VO250% ∆ and VO2max were 109 ± 15 W, 1.84 ± 0.23 L.min-1, 207 ± 17 W, 2.78 ± 0.27 L.min-1, 206 ± 19 W, 2.77 ± 0.29 L.min-1, and 3.71 ± 0.49 L.min-1, respectively. No signficant difference was found between CP and 50% ∆ (t = 0.16; p = 0.87) or between VO2CP and VO250% ∆ (t = 0.12; p = 0.90). However, the bias ± 95% limits of agreement for comparison between CP and 50% ∆ and between VO2CP and VO250% ∆ were 1 ± 27 W (0.3 ± 14.1%) and 0.01 ± 0.24 L.min-1 (0.2 ± 8.9%), respectively. In summary, the mean CP and 50% ∆ values were not significantly different. However, considering the limits of agreement between the two intensities, CP estimated based on 50% ∆ might result in a remarkable error when the absolute variability of individual differences is taken into account.

como citar · ABNT NBR 6023

SOUZA, Kristopher Mendes de et al. Agreement analysis between critical power and intensity corresponding to 50% ∆ in cycling exercise. Revista Brasileira de Cineantropometria & Desempenho Humano, 2016. DOI: 10.5007/1980-0037.2016V18N2P197.

Referências

30 obras citadas

  1. 1DC Poole e AM Jones. Oxygen uptake kinetics. Compr Physiol, 2012quem mais cita →
  2. 2HB Rossiter. Exercise: Kinetic considerations for gas exchange. Compr Physiol, 2011quem mais cita →
  3. 3RD de Lucas, KM Souza, VP Costa e mais 2. Time to exhaustion at and above critical power in trained cyclists: The relationship between heavy and severe intensity domains. Sci Sports, 2013quem mais cita →
  4. 4CC Greco, F Caputo e BS Denadai. Critical power and maximal oxygen uptake: Estimating the upper limit of the severe domain, a new challenge?. Sci Sports, 2008quem mais cita →
  5. 5W Chidnok, J Fulford, SJ Bailey e mais 4. Muscle metabolic determinants of exercise tolerance following exhaustion: relationship to the “critical power”. J Appl Physiol, 2013quem mais cita →
  6. 6AM Jones, A Vanhatalo, M Burnley e mais 2. Critical power: implications for the determination of VO2max and exercise tolerance. Med Sci Sports Exerc, 2010quem mais cita →
  7. 7AM Jones, DP Wilkerson, FJ DiMenna e mais 2. Muscle metabolic responses to exercise above and below the ‘critical power’ assessed using 31P-MRS. Am J Physiol Regul Integr Comp Physiol, 2008quem mais cita →
  8. 8A Vanhatalo, J Fulford, FJ DiMenna e mais 1. Influence of hyperoxia on muscle metabolic responses and the power-duration relationship during severe-intensity exercise in humans: a 31P magnetic resonance spectroscopy study. Exp Physiol, 2010quem mais cita →
  9. 9F Caputo e BS Denadai. Does 75% of the difference between VO2 at lactate threshold and VO2max lie at the severe-intensity domain in well-trained cyclists?. Sci Sports, 2009quem mais cita →
  10. 10H Carter, JS Pringle, AM Jones e mais 1. Oxygen uptake kinetics during treadmill running across exercise intensity domains. Eur J Appl Physiol, 2002quem mais cita →
  11. 11KE Lansley, FJ DiMenna, SJ Bailey e mais 1. A ‘new’ method to normalise exercise intensity. Int J Sports Medicine, 2011quem mais cita →
  12. 12H Carter, AM Jones, TJ Barstow e mais 3. Oxygen uptake kinetics in treadmill running and cycle ergometry: a comparison. J Appl Physiol, 2000quem mais cita →
  13. 13M Burnley, JH Doust e A Vanhatalo. A 3-min all-out test to determine peak oxygen uptake and the maximal steady state. Med Sci Sports Exerc, 2006quem mais cita →
  14. 14FJ DiMenna e AM Jones. “Linear” versus “nonlinear” VO2 responses to exercise: reshaping traditional beliefs. J Exerc Sci Fit, 2009quem mais cita →
  15. 15TM Johnson, PJ Sexton, AM Placek e mais 2. Reliability analysis of the 3-min all-out exercise test for cycle ergometry. Med Sci Sports Exerc, 2011quem mais cita →
  16. 16A Vanhatalo, JH Doust e M Burnley. Determination of critical power using a 3-min all-out cycling test. Med Sci Sports Exerc, 2007quem mais cita →
  17. 17JM Bland e DG Altman. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet, 1986quem mais cita →
  18. 18G Atkinson e T Reilly. Circadian variation in sports performance. Sports Med, 1996quem mais cita →
  19. 19AW Midgley, S Carroll, D Marchant e mais 2. Evaluation of true maximal oxygen uptake based on a novel set of standardized criteria. Appl Physiol Nutr Metab, 2009quem mais cita →
  20. 20DC Poole, DP Wilkerson e AM Jones. Validity of criteria for establishing maximal O2 uptake during ramp exercise tests. Eur J Appl Physiol, 2008quem mais cita →
1–20 de 30 obras citadas

Quem cita esta obra

1 artigo do acervo

quem fala desta obra

6 pessoas

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações