International Archives of Otorhinolaryngology2024
Active Bone Conduction Implant and Adhesive Bone Conduction Device: A Comparison of Audiological Performance and Subjective Satisfaction
Maria Fernanda Di Gregorio, Carolina Der, Sofia Bravo-Torres e Mario Emilio Zernotti
em inglês
resumo
Abstract Introduction Atresia of the external auditory canal affects 1 in every 10 thousand to 20 thousand live births, with a much higher prevalence in Latin America, at 5 to 21 out of every 10 thousand newborns. The treatment involves esthetic and functional aspects. Regarding the functional treatment, there are surgical and nonsurgical alternatives like spectacle frames and rigid and softband systems. Active transcutaneous bone conduction implants (BCIs) achieve good sound transmission and directly stimulate the bone. Objective To assess the audiological performance and subjective satisfaction of children implanted with an active transcutaneous BCI for more than one year and to compare the outcomes with a nonsurgical adhesive bone conduction device (aBCD) in the same users. Methods The present is a prospective, multicentric study. The audiological performance was evaluated at 1, 6, and 12 months postactivation, and after a 1-month trial with the nonsurgical device. Results Ten patients completed all tests. The 4-frequency pure-tone average (4PTA) in the unaided condition was of 65 dB HL, which improved significantly to 20 dB HL after using the BCI for 12 months. The speech recognition in quiet in the unaided condition was of 33% on average, which improved significantly, to 99% with the BCI, and to 91% with the aBCD. Conclusion The aBCD demonstrated sufficient hearing improvement and subjective satisfaction; thus, it is a good solution for hearing rehabilitation if surgery is not desired or not possible. If surgery is an option, the BCI is the superior device in terms of hearing outcomes, particularly background noise and subjective satisfaction.
como citar · ABNT NBR 6023
DI GREGORIO, Maria Fernanda et al. Active Bone Conduction Implant and Adhesive Bone Conduction Device: A Comparison of Audiological Performance and Subjective Satisfaction. International Archives of Otorhinolaryngology, 2024. DOI: 10.1055/S-0043-1777416.
Referências
38 obras citadas
- 1MA El-Begermy, OI Mansour, AM El-Makhzangy e mais 1. Congenital auditory meatal atresia: a numerical review. Eur Arch Otorhinolaryngol, 2009quem mais cita →
- 2LV Pereira e B. F. Jr. Up to Date on Etiology and Epidemiology of Hearing Loss. Update On Hearing Loss [Internet], 2015quem mais cita →
- 3JF Lo, WS Tsang, JY Yu e mais 3. Contemporary hearing rehabilitation options in patients with aural atresia. BioMed Res Int, 2014quem mais cita →
- 4DV Luquetti, CL Heike, AV Hing e mais 2. Microtia: epidemiology and genetics. Am J Med Genet A, 2012quem mais cita →
- 5ME Zernotti, MM Chiaraviglio, SB Mauricio e mais 3. Audiological outcomes in patients with congenital aural atresia implanted with transcutaneous active bone conduction hearing implant. Int J Pediatr Otorhinolaryngol, 2019quem mais cita →
- 6R Siegert, S Mattheis e J Kasic. Fully implantable hearing aids in patients with congenital auricular atresia. Laryngoscope, 2007quem mais cita →
- 7X Long, N Yu, J Huang e mais 1. Complication rate of autologous cartilage microtia reconstruction: a systematic review. Plast Reconstr Surg Glob Open, 2013quem mais cita →
- 8P Westerkull. An adhesive bone conduction system, ADHEAR, a new treatment option for conductive hearing losses. J Hear Sci, 2018quem mais cita →
- 9A Favoreel, E Heuninck e AL Mansbach. Audiological benefit and subjective satisfaction of children with the ADHEAR audio processor and adhesive adapter. Int J Pediatr Otorhinolaryngol, 2020quem mais cita →
- 10S Reinfeldt, B Håkansson, H Taghavi e mais 1. Bone conduction hearing sensitivity in normal-hearing subjects: transcutaneous stimulation at BAHA vs BCI position. Int J Audiol, 2014quem mais cita →
- 11V Dahm, AB Auinger, R Liepins e mais 3. A Randomized Cross-over Trial Comparing a Pressure-free, Adhesive to a Conventional Bone Conduction Hearing Device. Otol Neurotol, 2019quem mais cita →
- 12T Gawliczek, F Munzinger, L Anschuetz e mais 3. Unilateral and Bilateral Audiological Benefit With an Adhesively Attached, Noninvasive Bone Conduction Hearing System. Otol Neurotol, 2018quem mais cita →
- 13K Neumann, JP Thomas, C Voelter e mais 1. A new adhesive bone conduction hearing system effectively treats conductive hearing loss in children. Int J Pediatr Otorhinolaryngol, 2019quem mais cita →
- 14V Colletti, SD Soli, M Carner e mais 1. Treatment of mixed hearing losses via implantation of a vibratory transducer on the round window. Int J Audiol, 2006quem mais cita →
- 15G Sprinzl, T Lenarz e A Ernst. First European multicenter results with a new transcutaneous bone conduction hearing implant system: short-term safety and efficacy. Otol Neurotol, 2013quem mais cita →
- 16S Reinfeldt, B Håkansson, H Taghavi e mais 1. New developments in bone-conduction hearing implants: a review. Med Devices (Auckl), 2015quem mais cita →
- 17GM Sprinzl e A Wolf-Magele. The Bonebridge Bone Conduction Hearing Implant: indication criteria, surgery and a systematic review of the literature. Clin Otolaryngol, 2016quem mais cita →
- 18J Nazer, G Lay-Son e L Cifuentes. [Prevalence of microtia and anotia at the maternity of the University of Chile Clinical Hospital]. Rev Med Chil, 2006quem mais cita →
- 19ME Zernotti, CA Curet, S Cortasa e mais 2. Congenital Aural Atresia prevalence in the Argentinian population. Acta Otorrinolaringol Esp (Engl Ed), 2019quem mais cita →
- 20A Fuente e B McPherson. Auditory processing tests for Spanish-speaking adults: an initial study. Int J Audiol, 2006quem mais cita →