Reproducibility and construct validity of three non-invasive instruments for assessing the trunk range of motion in patients with low back pain
Gabrielle Zoldan Ganzalez, Lucíola da Cunha Menezes Costa, Alessandra Narciso Garcia, Silvia Regina Shiwa, Cesar Ferreira Amorim e Leonardo Oliveira Pena Costa
em inglês
citado por 1 artigocita 30 obras, 1 no acervo
resumo
Although there is a wide variety of methods and instruments aiming to assess the trunk range of motion, there is uncertainty regarding their construct validity and reproducibility. The objective of this study was to verify the construct validity and intra and inter-rater reproducibility of the goniometer, inclinometer and electrogoniometer in measuring the trunk range of motion in patients with history of low back pain. The measurement properties of reliability, agreement and construct validity were tested in 58 patients with low back pain using a test-retest design at baseline and after 24 to72 hours. All instruments showed good construct validity (r>0.60) as well as good levels of intra and inter-rater reliability with measurement errors ranging from 2.83 to 16.42 degrees. Among the assessed movements, the inclinometer, goniometer and electrogoniometer instruments can be considered as having good levels of construct validity and reproducibility for the assessment of trunk range of motion in patients with low back pain.
como citar · ABNT NBR 6023
GANZALEZ, Gabrielle Zoldan et al. Reproducibility and construct validity of three non-invasive instruments for assessing the trunk range of motion in patients with low back pain. Fisioterapia e Pesquisa, 2014. Disponível em: https://www.scielo.br/scielo.php?script=sci_arttext&pid=S1809-29502014000400365. Acesso em: 29 nov. 2026.
Referências
30 obras citadas · 1 no acervo
- 1MV Tulder. Chapter 1. European guidelines. Eur Spine J, 2006quem mais cita →
- 2S Dagenais, J Caro e S Haldeman. A systematic review of low back pain cost of illness studies in the United States and internationally. Spine J, 2008quem mais cita →
- 3C Littlewood e S May. Measurement of range of movement in the lumbar spine-what methods are valid? A systematic review. Physiotherapy, 2007quem mais cita →
- 4FB Ensink, PM Saur, K Frese e mais 2. Lumbar range of motion: influence of time of day and individual factors on measurements. Spine, 1996quem mais cita →
- 5DJ Magee. Avaliação musculoesquelética. 2002quem mais cita →
- 6P Schöber. The lumbar vertebral column in backache. Munch Med Wochenschr, 1937quem mais cita →
- 7CJ Barrett, KP Singer e R Day. Assessment of combined movements of the lumbar spine in asymptomatic and low back pain subjects using a three-dimensional electromagnetic tracking system. Man Ther, 1999quem mais cita →
- 8JK Ng, V Kippers, CA Richardson e mais 1. Range of motion and lordosis of the lumbar spine: reliability of measurement and normative values. Spine, 2001quem mais cita →
- 9JG Khalil, A Nassr e TP Maus. Physiologic imaging of the spine. Radiol Clin North Am, 2012quem mais cita →
- 10CL Nattrass, JE Nitschke, PB Disler e mais 2. Lumbar spine range of motion as a measure of physical and functional impairment: an investigation of validity. Clin Rehabil, 1999quem mais cita →
- 11JE Nitschke, CL Nattrass, PB Disler e mais 2. Reliability of the American Medical Association guides' model for measuring spinal range of motion. Its implication for whole-person impairment rating. Spine, 1999quem mais cita →
- 12MG Gillan, JC Ross, IP McLean e mais 1. The natural history of trunk list, its associated disability and the influence of McKenzie management. Eur Spine J, 1998quem mais cita →
- 13RG Burdett, KE Brown e MP Fall. Reliability and validity of four instruments for measuring lumbar spine and pelvic positions. Phys Therapy, 1986quem mais cita →
- 14JL Merritt, TJ McLean, RP Erickson e mais 1. Measurement of trunk flexibility in normal subjects: reproducibility of three clinical methods. Mayo Clin Proc, 1986quem mais cita →
- 15KA Olson e MT Goehring. Intra and inter-rater reliability of a goniometric lower trunk rotation measurement. J Back Musculoskelet Rehabil, 2009quem mais cita →
- 16M Troke, AP Moore, FJ Maillardet e mais 2. A new, comprehensive normative database of lumbar spine ranges of motion. Clin Rehabil, 2001quem mais cita →
- 17HC de Vet, CB Terwee, DL Knol e mais 1. When to use agreement versus reliability measures. J Clin Epidemiol, 2006quem mais cita →
- 18PE Shrout e JL Fleiss. Intraclass correlations: uses in assessing rater reliability. Psychological bulletin, 1979quem mais cita →
- 19LO Costa, CG Maher, J Latimer e mais 3. Clinimetric testing of three self-report outcome measures for low back pain patients in Brazil: which one is the best?. Spine, 2008quem mais cita →
- 20LO Costa, CG Maher, J Latimer e mais 3. Psychometric characteristics of the Brazilian-Portuguese versions of the Functional Rating Index and the Roland Morris Disability Questionnaire. Spine, 2007quem mais cita →
Quem cita esta obra
1 artigo do acervo
quem fala desta obra
3 pessoas- Bárbara Iansã de Lima Barroso1 artigo · 2017
- Mairana Maria Angélica Santos1 artigo · 2017
- Erivaldo Lopes de Souza1 artigo · 2017