Brazilian Journal of Otorhinolaryngology2026

Cochlear size variation among the Argentinian population

Maria Fernanda Di Gregorio, Ana Celeste Ferrari, Anandhan Dhanasingh, Maximo Zernotti e Mario Zernotti

em inglês

cita 25 obras

resumo

Abstract Objective Cochlear size, shape and the anatomy vary a lot among the human population. Cochlear size is a clinically useful parameter to determine the suitable cochlear implant electrode length. Objective is to assess the cochlear size and shape variation among the Argentine population. Methods Computer Tomography (CT) scans of 247 ears were assessed for the cochlear parameters including basal turn diameter (A-value) and width (B-value) and the cochlear height in the mid-modiolar section (H-value) using OTOPLAN® version 4.0. Shape of cochlear basal turn was determined by the ratio between B- and A-values. Cochlear Duct Length (CDL) was estimated from the A-, and B-values. Results The A-value was found to vary between 6.7 mm and 10.1 mm with a mean value of 8.7 ± 0.61 mm and the B-value was found to vary between 4.5 mm and 8.1 mm with a mean value of 6.4 ± 0.57 mm. The cochlear height as measured in the axial view from the mid-modiolar section was 3.78 ± 0.57 mm. Shape of the cochlear basal turn as determined by the ratio between B- and A-values showed 41 out of 248 ears (16.5%) have more of a round shaped basal turn with the ratio of ≥0.75 leaving the remaining 207 ears (83.5%) with more of an elliptical shaped basal turn. CDL was found to vary between 24.5 mm and 41.2 mm with a median value of 33.6 mm. Conclusion Argentine population appears to have slightly smaller cochlear size compared to population from other countries as reported in literature. Level of evidence: 3.

como citar · ABNT NBR 6023

DI GREGORIO, Maria Fernanda et al. Cochlear size variation among the Argentinian population. Brazilian Journal of Otorhinolaryngology, 2026. DOI: 10.1016/J.BJORL.2025.101708.

Referências

25 obras citadas

  1. 1P.G. Shekelle, S.H. Woolf, M. Eccles e mais 1. Clinical guidelines: developing guidelines. BMJ, 1999quem mais cita →
  2. 2P. Van de Heyning, O. Adunka e S.L. Arauz. Standards of practice in the field of hearing implants. Cochlear Implants Int, 2013quem mais cita →
  3. 3J. Müller e C.H. Raine. Quality standards for adult cochlear implantation. Cochlear Implants Int, 2013quem mais cita →
  4. 4J. Martin e C.H. Raine. Quality standards for cochlear implantation in children and young adults. Cochlear Implants Int, 2013quem mais cita →
  5. 5S. Dazert, J.P. Thomas, A. Loth e mais 2. Cochlear implantation. Dtsch Arztebl Int, 2020quem mais cita →
  6. 6A. Dhanasingh e I. Hochmair. Signal processing & audio processors. Acta Otolaryngol, 2021quem mais cita →
  7. 7A. Dhanasingh, S.B. Nielsen e F. Beal. Cochlear implant electrode design for safe and effective treatment. Front Neurol, 2024quem mais cita →
  8. 8T.M. Breitsprecher, W.D. Baumgartner e K. Brown. Effect of cochlear implant electrode insertion depth on speech perception outcomes: a systematic review. Otol Neurotol Open, 2023quem mais cita →
  9. 9G. Alexiades, A. Dhanasingh e C. Jolly. Method to estimate the complete and two-turn cochlear duct length. Otol Neurotol, 2015quem mais cita →
  10. 10D. Schurzig, M.E. Timm, O. Majdani e mais 2. The use of clinically measurable cochlear parameters in cochlear implant surgery as indicators for size, shape, and orientation of the scala Tympani. Ear Hear, 2021quem mais cita →
  11. 11A. Alahmadi, Y. Abdelsamad, A. Dhanasingh e mais 2. Enhancing cochlear duct length estimation by incorporating second-turn parameters. Sci Rep, 2023quem mais cita →
  12. 12T. Khurayzi, A. Dhanasingh, F. Almuhawas e mais 1. Shape of the cochlear basal turn: an indicator for an optimal electrode-to-modiolus proximity with precurved electrode type. Ear Nose Throat J, 2021quem mais cita →
  13. 13B. Escudé, C. James, O. Deguine e mais 3. The size of the cochlea and predictions of insertion depth angles for cochlear implant electrodes. Audiol Neurootol, 2006quem mais cita →
  14. 14A. Dhanasingh. Research software in cochlear duct length estimation, greenwood frequency mapping and CI electrode array length simulation. World J Otorhinolaryngol Head Neck Surg, 2020quem mais cita →
  15. 15M.E. Zernotti, C.A. Curet, S. Cortasa e mais 2. Congenital Aural Atresia prevalence in the Argentinian population. Acta Otorrinolaringol Esp (Engl Ed), 2019quem mais cita →
  16. 16S.A. Avena, A.S. Goicoechea, J. Rey e mais 3. Mezcla genica en una muestra poblacional de la Ciudad de Buenos Aires [Gene mixture in a population sample from Buenos Aires City]. Medicina (B Aires), 2006quem mais cita →
  17. 17M.F. Seldin, C. Tian e R. Shigeta. Argentine population genetic structure: large variance in Amerindian contribution. Am J Phys Anthropol, 2007quem mais cita →
  18. 18M. Hardy. The length of the organ of Corti in man. Am J Anat, 1938quem mais cita →
  19. 19Y. Chen, J. Chen e H. Tan. Cochlear duct length calculation: comparison between using otoplan and curved multiplanar reconstruction in nonmalformed cochlea. Otol Neurotol, 2021quem mais cita →
  20. 20H. Yoshimura, K. Watanabe, S.Y. Nishio e mais 2. Determining optimal cochlear implant electrode array with OTOPLAN. Acta Otolaryngol, 2023quem mais cita →
1–20 de 25 obras citadas

Quem cita esta obra

nenhum artigo do acervo cita esta obra — ainda

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações