Clinics2019

Morse taper performance: A finite element analysis study

Gustavo Passarelli Petris, João Paulo De Carli, Luiz Renato Paranhos, Pâmela Letícia Santos, Paula Benetti, Marcio Walber, Eduardo Sandini Linden e Maria Salete Sandini Linden

em inglês

citado por 1 artigocita 17 obras

resumo

OBJECTIVES: To evaluate and compare the magnitude and distribution of stresses generated on implants, abutments and first molar metal-ceramic crowns using finite element analysis. METHODS: Preliminary three-dimensional models were created using the computer-aided design software SolidWorks. Stress and strain values were observed for two distinct virtual models: model 1 - Morse taper and solid abutment; model 2 - Morse taper and abutment with screw. A load (250 N) was applied to a single point of the occlusal surface at 15° to the implant long axis. Von Mises stresses were recorded for both groups at four main points: 1) abutment-retaining screws; 2) abutment neck; 3) cervical bone area; 4) implant neck. RESULTS AND CONCLUSION: Model 1 showed a higher stress value (1477.5 MPa) at the abutment-retaining screw area than the stresses found in model 2 (1091.1 MPa for the same area). The cervical bone strain values did not exceed 105 µm for either model.

como citar · ABNT NBR 6023

PETRIS, Gustavo Passarelli et al. Morse taper performance: A finite element analysis study. Clinics, 2019. DOI: 10.6061/CLINICS/2019/E852.

Referências

17 obras citadas

  1. 1HW Wiskott, JI Nichols e UC Belser. Stress fatigue: basic principles and prosthodontic implications. Int J Prosthodont, 1995quem mais cita →
  2. 2A Geramy e SM Morgano. Finite element analisys of three designs of an implant-supported molar crown. J Prosthet Dent, 2004quem mais cita →
  3. 3PP Binon. Implants and components: entering the new millennium. Int J Oral Maxillofac Implants, 2000quem mais cita →
  4. 4AR Coppedê, E Bersani, G De Mattos Mda e mais 3. Fracture resistance of the implant-abutment connection in implants with internal hex and internal conical connections under oblique compressive loading: an in vitro study. Int J Prosthodont, 2009quem mais cita →
  5. 5A Alves Filho. Elementos finitos: A base da tecnologia CAE. 2000quem mais cita →
  6. 6JP Geng, KB Tan e GR Liu. Application of finite element analysis in implant dentistry: A review of the literature. J Prosthet Dent, 2001quem mais cita →
  7. 7BR Merz, S Hunenbart e UC Belser. Mechanics of the implant-abutment connection: an 8-degree taper compared to a butt joint connection. Int J Oral Maxillofac Implants, 2000quem mais cita →
  8. 8RS Pessoa, L Muraru, EM Júnior e mais 3. Influence of implant connection type on the biomechanical environment of immediately placed implants - CT-based nonlinear, three-dimensional finite element analysis. Clin Implant Dent Relat Res, 2010quem mais cita →
  9. 9KJ Anusavice. Phillips’ Science of Dental Materials. 10th Edition. 1996quem mais cita →
  10. 10JR Kelly, I Nishimura e SD Campbell. Ceramics in dentistry: Historical roots and current perspectives. J Prosthet Dent, 1996quem mais cita →
  11. 11S Moaveni. Finite element analysis: theory and application with ANSYS. 2003quem mais cita →
  12. 12JH Bickford. An Introduction to the Design and Behavior of Bolted Joints. 1990quem mais cita →
  13. 13D Bozkaya e S Muftu. Mechanics of the tapered interference fit in dental implants. J Biomech, 2003quem mais cita →
  14. 14A Bacchi, RL Consani, MF Mesquita e mais 1. Effect of framework material and vertical misfit on stress distribution in implant-supported partial prosthesis under load application: 3-D finite element analysis. Acta Odontol Scand, 2013quem mais cita →
  15. 15JB Brunski. Biomechanical factors affecting the bone-dental implant interface. Clin Mater, 1992quem mais cita →
  16. 16L Geris, A Andreykiv, H Van Oosterwyck e mais 3. Numerical simulation of tissue differentiation around loaded titanium implants in a bone chamber. J Biomech, 2004quem mais cita →
  17. 17K Vandamme, I Naert, L Geris e mais 3. The effect of micro-motion on the tissue response around immediately loaded roughened titanium implants in the rabbit. Eur J Oral Sci, 2007quem mais cita →

Quem cita esta obra

1 artigo do acervo

quem fala desta obra

4 pessoas

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações