OBJECTIVE: The aim of this study was to compare the efficiency of multiplanar reformatted images and threedimensional images created after multidetector computed tomography examination in detecting acute posttraumatic osseous pathology of the skeletal system. METHOD: Between October 2006 and December 2008, 105 patients with a history of acute trauma were referred to our service. Patients were evaluated with multidetector computed tomography using multiplanary reconstructed images initially (R-I), and six months after this initial evaluation, three-dimensional images were assessed of each patient (R-II). Axial images were used for guiding as a reference Data obtained was recorded and graded according to importance levels of the pathologies. RESULTS: The R-II score was higher in the non-articular and highest in periartricular fractures of the extremities, and thoracic and pelvic cage injuries. For the spinal column, while R-I data was more significant In patients referred with polytrauma, R-II data, was more statistically significant, for short processing and adaptation time to acquiring immediate critical information. For all cases it was seen that three dimensional scans were more efficient in providing the orientation, within a short time. CONCLUSION: By dual source multidedector tomography systems trauma patients may be evaluated by multiplanary and three dimensionally reconstructed images. When used correctly, three dimensional imaging is advantageous and can help determine the exact nature and extension and also importance of osseous injuries.

como citar · ABNT NBR 6023

YILDIRIM, Duzgun; TAMAM, Cuneyt; GUMUS, Terman. Three-dimensional scanning with dual-source computed tomography in patients with acute skeletal trauma. Clinics, 2010. Disponível em: https://www.scielo.br/scielo.php?script=sci_arttext&pid=S1807-59322010001000012. Acesso em: 27 nov. 2026.

Referências

25 obras citadas

  1. 1GY El-Khoury, DL Bennett e GJ Ondr. Multidetector-row computed tomography. J Am Acad Orthop Surg, 2004quem mais cita →
  2. 2NC Dalrymple, SR Prasad, MW Freckleton e mais 1. Informatics in radiology (infoRAD): introduction to the language of three-dimensional imaging with multidetector CTquem mais cita →
  3. 3LS Medina. Three-dimensional CT maximum intensity projections of the calvaria: a new approach for diagnosis of craniosynostosis and fractures. AJNR Am J Neuroradiol, 2000quem mais cita →
  4. 4M Wintermark, E Mouhsine, N Theumann e mais 3. Thoracolumbar spine fractures in patients who have sustained severe trauma: depiction with multi-detector row CT. Radiology, 2003quem mais cita →
  5. 5C Suess e X Chen. Dose optimization in pediatric CT: current technology and future innovations. Pediatr Radiol, 2002quem mais cita →
  6. 6RA Novelline, JT Rhea, PM Rao e mais 1. Helical CT in emergency radiology. Radiology, 1999quem mais cita →
  7. 7MO Philipp, K Kubin, M Hormann e mais 1. Radiological emergency room management with emphasis on multidetector-row CT. Eur J Radio.l, 2003quem mais cita →
  8. 8A Prokop, H Hötte, K Krüger e mais 3. Multislice CT in diagnostic work-up of polytrauma [in German]. Unfallchirurg, 2006quem mais cita →
  9. 9J Gralla, F Spycher, C Pignolet e mais 3. Evaluation of a 16-MDCT scanner in an emergency department: initial clinical experience and workflow analysis. AJR, 2005quem mais cita →
  10. 10T Ptak, J Rhea e R Novelline. Experience with a continuous, single-pass whole-body multidetector CT protocol for trauma: the three-minute multiple trauma CT scan. Emerg Radiol, 2001quem mais cita →
  11. 11JE Roos, LM Desbiolles, JK Willmann e mais 3. Multidetector-row helical CT: analysis of time management and workflow. Eur Radiol, 2002quem mais cita →
  12. 12ES Pretorius e EK Fishman. Volume-rendered threedimensional spiral CT: musculoskeletal applications. RadioGraphics, 1999quem mais cita →
  13. 13D Tomazevic, B Likar e F Pernus. Reconstruction-based 3D/2D image registration. Med Image Comput Comput Assist Interv Int Conf Med Image Comput Comput Assist Interv, 2005quem mais cita →
  14. 14EM van Gennip, K Heiska, GJ Kemerink e mais 3. Overview of CAPACITY data. Int J Biomed Comput, 1992quem mais cita →
  15. 15JM Eisenberg. Clinical economics: a guide to the economic analysis of clinical practices. JAMA, 1989quem mais cita →
  16. 16LM Fayad, F Corl e EK Fishman. Pediatric skeletal trauma: use of multiplanar reformatted and three-dimensional 64-row multidetector CT in the emergency department. Radiographics, 2009quem mais cita →
  17. 17B Coulier. Direct 3D imaging of the knee menisci during 16-row multislice CT arthrography. JBR-BTR, 2006quem mais cita →
  18. 18K Ohashi, GY El-Khoury e DL Bennett. MDCT of tendon abnormalities using volume-rendered images. AJR Am J Roentgenol, 2004quem mais cita →
  19. 19BC Lucey, JW Stuhlfaut, AR Hochberg e mais 2. Evaluation of blunt abdominal trauma using PACS-based 2D and 3D MDCT reformations of the lumbar spine and pelvis. AJR Am J Roentgenol, 2005quem mais cita →
  20. 20SW Anderson, BC Lucey, JC Varghese e mais 1. Sixty-four multi-detector row computed tomography in multitrauma patient imaging: early experience. Curr Probl Diagn Radiol, 2006quem mais cita →
1–20 de 25 obras citadas

Quem cita esta obra

2 artigos do acervo

ano a anomais citada em 2011 · 2 artigos
Mais citada em 2011, com 2 artigos.
  • 2011: citada em 2 artigos

quem fala desta obra

5 pessoas