Detection of horizontal root fracture using four different protocols of cone-beam computed tomography
Fernanda Cristina Sales SALINEIRO, Lucas Rodrigues PINHEIRO, Oséas dos SANTOS JÚNIOR e Marcelo Gusmão Paraiso CAVALCANTI
em inglês
citado por 3 artigoscita 20 obras, 1 no acervo
resumo
The purpose of this study was to analyze four different cone-beam computed tomography (CBCT) protocols to identify horizontal root fractures (HRF) in endodontically treated teeth, with or without the presence of a metallic post. Thirty extracted single-rooted human premolars were treated endodontically. Afterwards, an observer induced a horizontal fracture in 15 teeth. Each tooth was inserted in an empty mandibular socket and submitted to a computed tomography scan taken with and without the metallic post. The acquisition followed four different protocols, with different fields of view (FOV) and voxel sizes, as follows: FOV 6X16 cm/0.2 mm voxel; FOV 6X16 cm/0.25 mm voxel; FOV 8X8 cm/0.2 mm voxel; FOV 8X8 cm/0.25 mm voxel. Two observers checked all the acquisitions within a two-week interval, and the values of sensitivity, specificity, accuracy and kappa were calculated. The sensitivity, specificity and accuracy values were better for the 8X8 cm/0.2 mm and 16X6 cm/0.25 mm protocols, ranging from 0.60 to 0.86 and 0.53 to 0.80, respectively. The intra- and interobserver concordance ranged from 0.65 to 0.72. The protocols where FOV and voxel were proportional showed better results. The 8x8 cm/0.2 mm protocol had the least interference from the metallic artifact. All four protocols showed a decline in values in the presence of the metallic artifact.
como citar · ABNT NBR 6023
SALINEIRO, Fernanda Cristina Sales et al. Detection of horizontal root fracture using four different protocols of cone-beam computed tomography. Brazilian Oral Research, 2015. DOI: 10.1590/1807-3107BOR-2015.VOL29.0067.
Referências
20 obras citadas · 1 no acervo
- 1K Orhan, U Aksoy e A Kalender. Cone-beam computed tomographic evaluation of spontaneously healed root fracture. J Endod, 2010quem mais cita →
- 2T Testori, M Badino e M Castagnola. Vertical root fractures in endodontically treated teeth: a clinical survey of 36 cases. J Endod, 1993quem mais cita →
- 3WH Shintaku, JS Venturin, M Noujeim e mais 1. Comparison between intraoral indirect and conventional film-based imaging for the detection of dental root fractures: an ex vivo study. Dent Traumatol, 2013quem mais cita →
- 4FF Costa, BF Gaia, OS Umetsubo e mais 3. Use of large-volume cone-beam computed tomography in identification and localization of horizontal root fracture in the presence and absence of intracanal metallic post. J Endod, 2012quem mais cita →
- 5A Perrella, PML Lopes, RG Rocha e mais 2. Influence of dental metallic artifact from multislice CT in the assessment of simulated mandibular lesions. J Appl Oral Sci, 2010no acervo →
- 6ZT Librizzi, AS Tadinada, JV Valiyaparambil e mais 2. Cone-beam computed tomography to detect erosions of the temporomandibular joint: effect of field of view and voxel size on diagnostic efficacy and effective dose. Am J Orthod Dentofacial Orthop, 2011quem mais cita →
- 7FF Costa, BF Gaia, OS Umetsubo e mais 1. Detection of horizontal root fracture with small-volume cone-beam computed tomography in the presence and absence of intracanal metallic post. J Endod, 2011quem mais cita →
- 8B Hassan, ME Metska, AR Ozok e mais 2. Detection of vertical root fractures in endodontically treated teeth by a cone beam computed tomography scan. J Endod, 2009quem mais cita →
- 9A Wenzel e LL Kirkevang. High resolution charge-coupled device sensor vs medium resolution photostimulable phosphor plate digital receptors for detection of root fractures in vitro. Dent Traumatol, 2005quem mais cita →
- 10CR Moreira, MA Sales, PM Lopes e mais 1. Assessment of linear and angular measurements on three-dimensional cone-beam computed tomographic images. Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 2009quem mais cita →
- 11A Katsumata, A Hirukawa, S Okumura e mais 3. Effects of image artifacts on gray-value density in limited-volume cone-beam computerized tomography. Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 2007quem mais cita →
- 12A Katsumata, A Hirukawa, S Okumura e mais 3. Relationship between density variability and imaging volume size in cone-beam computerized tomographic scanning of the maxillofacial region: an in vitro study. Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 2009quem mais cita →
- 13DG Altman. Practical statistics for medical research. 1991quem mais cita →
- 14American Association of Endodontists e American Academy of Oral and Maxillofacial Radiology. Use of cone-beam computed tomography in endodontics. Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 2011quem mais cita →
- 15MGP Cavalcanti. Cone beam computed tomographic imaging: perspective, challenges, and the impact of near-trend future applications. J Craniofac Surg, 2012quem mais cita →
- 16B Bechara, CA McMahan, WS Moorei e mais 3. Contrast-to-noise ratio difference in small field of view cone beam computed tomography machines. J Oral Sci, 2012quem mais cita →
- 17M Iikubo, K Kobayashi, A Mishima e mais 3. Accuracy of intraoral radiography, multidetector helical CT, and limited cone-beam CT for the detection of horizontal tooth root fracture. Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 2009quem mais cita →
- 18K Kamburoğlu, B Önder, S Murat e mais 3. Radiographic detection of artificially created horizontal root fracture using different cone beam CT units with small fields of view. Dentomaxillofac Radiol, 2013quem mais cita →
- 19M Brito Júnior, LAN Santos, AL Faria-e-Silva e mais 2. Ex vivo evaluation of artifacts mimicking fracture lines on cone-beam computed tomography produced by different root canal sealers. Int Endod J, 2014quem mais cita →
- 20K Horner, R Jacobs e R Schulze. Dental CBCT equipment and performance issues. Radiat Prot Dosimetry, 2013quem mais cita →
Quem cita esta obra
3 artigos do acervo
- 2016: citada em 1 artigo
- 2017: citada em 1 artigo
- 2022: citada em 1 artigo
quem fala desta obra
14 pessoas- Marcelo Gusmão Paraiso Cavalcantiautocitação2 artigos · 2022
- Fabiana Mesquita Barros1 artigo · 2022
- Francisco Barbara Abreu Barros1 artigo · 2022
- Fernanda Cristina Salineiro1 artigo · 2022
- Ivan Onone GIALAIN1 artigo · 2017
- Solange KOBAYASHI-VELASCO1 artigo · 2017
- Fernanda Cristina Sales SALINEIROautocitação1 artigo · 2017
- Amin Mahdavi Asl1 artigo · 2016
- Amir Eskandarloo1 artigo · 2016
- Javad Fardmal1 artigo · 2016
os artigos
- Influence of endodontic sealers artifacts in the detection of vertical root fracturesMarcelo Gusmão Paraiso Cavalcanti e mais 3 · Brazilian Dental Journal · 2022
- Diagnosis of alveolar and root fractures: an in vitro study comparing CBCT imaging with periapical radiographsSolange KOBAYASHI-VELASCO e mais 3 · Journal of Applied Oral Science · 2017
- Effect of Time Lapse on the Diagnostic Accuracy of Cone Beam Computed Tomography for Detection of Vertical Root FracturesAmir Eskandarloo e mais 6 · Brazilian Dental Journal · 2016
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda