Evaluation of condyle defects using different reconstruction protocols of cone-beam computed tomography
Luana Costa Bastos, Paulo Sergio Flores Campos, Flavia Maria de Moraes Ramos-Perez, Andrea dos Anjos Pontual e Solange Maria Almeida
em inglês
resumo
This study was conducted to investigate how well cone-beam computed tomography (CBCT) can detect simulated cavitary defects in condyles, and to test the influence of the reconstruction protocols. Defects were created with spherical diamond burs (numbers 1013, 1016, 3017) in superior and/or posterior surfaces of twenty condyles. The condyles were scanned, and cross-sectional reconstructions were performed with nine different protocols, based on slice thickness (0.2, 0.6, 1.0 mm) and on the filters (original image, Sharpen Mild, S9) used. Two observers evaluated the defects, determining their presence and location. Statistical analysis was carried out using simple Kappa coefficient and McNemar's test to check inter- and intra-rater reliability. The chi-square test was used to compare the rater accuracy. Analysis of variance (Tukey's test) assessed the effect of the protocols used. Kappa values for inter- and intra-rater reliability demonstrate almost perfect agreement. The proportion of correct answers was significantly higher than that of errors for cavitary defects on both condyle surfaces (p < 0.01). Only in identifying the defects located on the posterior surface was it possible to observe the influence of the 1.0 mm protocol thickness and no filter, which showed a significantly lower value. Based on the results of the current study, the technique used was valid for identifying the existence of cavities in the condyle surface. However, the protocol of a 1.0 mm-thick slice and no filter proved to be the worst method for identifying the defects on the posterior surface.
como citar · ABNT NBR 6023
BASTOS, Luana Costa et al. Evaluation of condyle defects using different reconstruction protocols of cone-beam computed tomography. Brazilian Oral Research, 2013. DOI: 10.1590/S1806-83242013000600010.
Referências
16 obras citadas · 2 no acervo
- 1RC Berni, C Freitas, AT Gouveia e mais 2. [TMJ: study of the osseous abnormalities ocurrence by linear tomography]. Rev ABRO, 2003quem mais cita →
- 2KE Alexiou, HC Stamatakis e K Tsiklakis. Evaluation of the severity of temporomandibular joint osteoarthritic changes related to age using cone beam computed tomography. Dentomaxillofac Radiol, 2009quem mais cita →
- 3TA Larheim, K Dale e L Tveito. Radiographic abnormalities of the temporomandibular joint in children with juvenile rheumatoid arthritis. Acta Radiol Diagn (Stockh), 1981quem mais cita →
- 4LAN Santos, PSF Campos, AMP Paula e mais 2. [Image of juvenile idiopathic arthritis in mandibular condyle - case report]. Rev ABRO, 2005quem mais cita →
- 5AM Hussain, G Packota, PW Major e mais 1. Role of different imaging modalities in assessment of temporomandibular joint erosions and osteophytes: a systematic review. Dentomaxillofac Radiol, 2008quem mais cita →
- 6OB Honey, WC Scarfe, MJ Hilgers e mais 3. Accuracy of cone-beam computed tomography imaging of the temporomandibular joint: comparisons with panoramic radiology and linear tomography. Am J Orthod Dentofacial Orthop, 2007quem mais cita →
- 7K Honda, TA Larheim, K Maruhashi e mais 2. Osseous abnormalities of the mandibular condyle: diagnostic reliability of cone beam computed tomography compared with helical computed tomography based on an autopsy material. Dentomaxillofac Radiol, 2006quem mais cita →
- 8A Perrella, MA Borsatti, IP Tortamano e mais 2. Validation of computed tomography protocols for simulated mandibular lesions: a comparison study. Braz Oral Res, 2007no acervo →
- 9P Eickholz, T Riess, M Lenhard e mais 2. Digital radiography of interproximal bone loss; validity of different filters. J Clin Periodontol, 1999quem mais cita →
- 10F Haiter-Neto, AA Pontual, M Frydenberg e mais 1. Detection of non-cavitated approximal caries lesions in digital images from seven solid-state receptors with particular focus on task-specific enhancement filters. An ex vivo study in human teeth. Clin Oral Investig, 2008quem mais cita →
- 11A Wenzel, F Haiter-Neto, M Frydenberg e mais 1. Variable-resolution cone-beam computerized tomography with enhancement filtration compared with intraoral photostimulable phosphor radiography in detection of transverse root fractures in an in vitro model. Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 2008quem mais cita →
- 12SLA Vaz, TV Vasconcelos, FS Neves e mais 2. Influence of cone-beam computed tomography enhancement filters on diagnosis of simulated external root resorption. J Endod, 2012quem mais cita →
- 13ER Utumi, A Perrella, MAP Albuquerque e mais 3. Evaluation of simulated bone lesion in the head of the mandible by using multislice computed tomography. J Appl Oral Sci, 2009no acervo →
- 14ACB Cara, BF Gaia, A Perrella e mais 3. Validity of single- and multislice CT for assessment of mandibular condyle lesions. Dentomaxillofac Radiol, 2007quem mais cita →
- 15H Hintze, M Wiese e A Wenzel. Cone beam CT and conventional tomography for the detection of morphological temporomandibular joint changes. Dentomaxillofac Radiol, 2007quem mais cita →
- 16X Liang, R Jacobs, B Hassan e mais 3. A comparative evaluation of cone beam computed tomography (CBCT) and multi-slice CT (MSCT) Part I. On subjective image quality. Eur J Radiol, 2010quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda