Brazilian Oral Research2011

Is miniscrew primary stability influenced by bone density?

Mariana Marquezan, Margareth Maria Gomes de Souza, Mônica Tirre de Souza Araújo, Lincoln Issamu Nojima e Matilde da Cunha Gonçalves Nojima

em inglês

citado por 5 artigoscita 30 obras

resumo

Primary stability is absence of mobility in the bone bed after mini-implant placement and depends on bone quality among other factors. Bone quality is a subjective term frequently considered as bone density. The aim of this preliminary study was to evaluate bone density in two bovine pelvic regions and verify the primary stability of miniscrews inserted into them. Forty bone blocks were extracted from bovine pelvic bones, 20 from iliac and 20 from pubic bone, all of them containing cortical bone about 1 mm thick. Half of the sections extracted from each bone were designated for histological evaluation of bone density (trabecular bone area - TBA) and the other half for bone mineral density (BMD) evaluation by means of central dual-energy X-ray absorptiometry (DEXA). Then, twenty self-drilling miniscrews (INPÒ, São Paulo, Brazil) 1.4 mm in diameter and 6 mm long were inserted into the bone blocks used for BMD evaluation. Peak implant insertion torque (IT) and pull-out strength (PS) were used for primary stability evaluation. It was found that iliac and pubic bones present different bone densities, iliac bone being less dense considering BMD and TBA values (P > 0.05). However, the miniscrew primary stability was not different when varying the bone type (P < 0.05). IT and PS were not influenced by these differences in bone density when cortical thickness was about 1 mm thick.

como citar · ABNT NBR 6023

MARQUEZAN, Mariana et al. Is miniscrew primary stability influenced by bone density? Brazilian Oral Research, 2011. Disponível em: https://www.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242011000500009. Acesso em: 28 nov. 2026.

Referências

30 obras citadas

  1. 1L Molly. Bone density and primary stability in implant therapy. Clin Oral Implants Res, 2006quem mais cita →
  2. 2F Javed e GE Romanos. The role of primary stability for successful immediate loading of dental implants: A literature review. J Dent, 2010quem mais cita →
  3. 3T Gedrange, V Hietschold, R Mai e mais 3. An evaluation of resonance frequency analysis for the determination of the primary stability of orthodontic palatal implants: A study in human cadavers. Clin Oral Implants Res, 2005quem mais cita →
  4. 4B Wilmes, C Rademacher, G Olthoff e mais 1. Parameters affecting primary stability of orthodontic mini-implants. J Orofac Orthop, 2006quem mais cita →
  5. 5YY Song, JY Cha e CJ Hwang. Mechanical characteristics of various orthodontic mini-screws in relation to artificial cortical bone thickness. Angle Orthod, 2007quem mais cita →
  6. 6P Trisi, S De Benedittis, G Perfetti e mais 1. Primary stability, insertion torque and bone density of cylindric implant ad modum Branemark: Is there a relationship? An in vitro study. Clin Oral Implants Res, 2011quem mais cita →
  7. 7JW Freudenthaler, R Haas e HP Bantleon. Bicortical titanium screws for critical orthodontic anchorage in the mandible: a preliminary report on clinical applications. Clin Oral Implants Res, 2001quem mais cita →
  8. 8SJ Cheng, IY Tseng, JJ Lee e mais 1. A prospective study of the risk factors associated with failure of mini-implants used for orthodontic anchorage. Int J Oral Maxillofac Implants, 2004quem mais cita →
  9. 9RA Mischkowski, P Kneuertz, B Florvaag e mais 3. Biomechanical comparison of four different miniscrew types for skeletal anchorage in the mandibulo-maxillary area. Int J Oral Maxillofac Surg, 2008quem mais cita →
  10. 10B Melsen e A Costa. Immediate loading of implants used for orthodontic anchorage. Clin Orthod Res, 2000quem mais cita →
  11. 11JS Garfinkle, LL Jr. Cunningham, CS Beeman e mais 3. Evaluation of orthodontic mini-implant anchorage in premolar extraction therapy in adolescents. Am J Orthod Dentofacial Orthop, 2008quem mais cita →
  12. 12J Merheb, N Van Assche, W Coucke e mais 3. Relationship between cortical bone thickness or computerized tomography-derived bone density values and implant stability. Clin Oral Implants Res, 2010quem mais cita →
  13. 13MC Cehreli, AM Kokat, A Comert e mais 3. Implant stability and bone density: assessment of correlation in fresh cadavers using conventional and osteotome implant sockets. Clin Oral Implants Res, 2009quem mais cita →
  14. 14G Bergkvist, KJ Koh, S Sahlholm e mais 2. Bone density at implant sites and its relationship to assessment of bone quality and treatment outcome. Int J Oral Maxillofac Implants, 2010quem mais cita →
  15. 15U Lekholm e G Zarb. Patient selection and preparation. Tissue-integrated prostheses: osseointegration in clinical dentistry, 1985quem mais cita →
  16. 16JJ Carey, MF Delaney, TE Love e mais 3. DXA-generated Z-scores and T-scores may differ substantially and significantly in young adults. J Clin Densitom, 2007quem mais cita →
  17. 17MM Pithon, ACDV Andrade, VB Rodrigues e mais 1. Influence of the immunossuppressant tracolimus (FK-506) on the flexural strength of femur: a study in rats. Rev Bras Ortop, 2010quem mais cita →
  18. 18A Morse. Formic acid-sodium citrate decalcification and butyl alcohol dehydration of teeth and bones for sectioning in paraffin. J Dent Res, 1945quem mais cita →
  19. 19SS Huja, AS Litsky, FM Beck e mais 2. Pull-out strength of monocortical screws placed in the maxillae and mandibles of dogs. Am J Orthod Dentofacial Orthop, 2005quem mais cita →
  20. 20C Wawrzinek, T Sommer e H Fischer-Brandies. Microdamage in cortical bone due to the overtightening of orthodontic microscrews. J Orofac Orthop, 2008quem mais cita →
1–20 de 30 obras citadas

Quem cita esta obra

5 artigos do acervo

ano a anomais citada em 2012 · 1 artigo
Mais citada em 2012, com 1 artigo.
  • 2012: citada em 1 artigo
  • 2013: citada em 1 artigo
  • 2015: citada em 1 artigo
  • 2021: citada em 1 artigo
  • 2023: citada em 1 artigo

quem fala desta obra

29 pessoas
ver as 29 pessoas e os artigos →