Polymerization time for a microwave-cured acrylic resin with multiple flasks
Daniela Maffei Botega, Tatiana de Souza Machado, José Antônio Nunes de Mello, Renata Cunha Matheus Rodrigues Garcia e Altair Antoninha Del Bel Cury
em inglês
citado por 1 artigocita 18 obras
resumo
This study aimed at establishing the polymerization time of a microwave-cured acrylic resin (AcronTM MC), simultaneously processing 2, 4, and 6 flasks. Required time was measured according to the parameters: monomer release in water, Knoop hardness, and porosity. Samples were made with AcronTM MC in different shapes: rectangular (32 x 10 x 2.5 mm) for monomer release and porosity; and half-disc (30 mm in diameter x 4 mm in height) for Knoop hardness. There were four experimental groups (n = 24 per group): G1) one flask (control); G2) two flasks; G3) four flasks, and G4) six flasks. At first, polymerization protocol was similar for all groups (3 min/450 W). Time was then adjusted for G2, G3, and G4, based on monomer release evaluation in the control group, obtained by spectrophotometer Beckman DU-70, with emitting wave of 206 nm. Knoop hardness test was performed using a Shimadzu HMV 2000 hardness tester, and 10 indentations were performed on each specimen's surface. Porosity was assessed after specimens were immersed in black ink and the pores counted in a microscope. Results showed that the complete polymerization of the resin occurred in 4.5 min for two flasks (G2); 8.5 min for four flasks (G3); and 13 min for six flasks (G4), all with 450 W. Statistical analysis revealed that the number of flasks does not interfere with polymerization, Knoop hardness, and porosity of the resin. Results showed that polymerization of microwave-curing resin with more than one flask is a viable procedure, as long as polymerization time is adjusted.
como citar · ABNT NBR 6023
BOTEGA, Daniela Maffei et al. Polymerization time for a microwave-cured acrylic resin with multiple flasks. Brazilian Oral Research, 2004. Disponível em: https://www.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242004000100005. Acesso em: 29 nov. 2026.
Referências
18 obras citadas
- 1D Al Doori, R Huggett, JF Bates e mais 1. A comparison of denture base acrylic resins polymerised by microwave irradiation and by conventional water bath curing systems. Dent Mater, 1988quem mais cita →
- 2KJ Anusavice. Phillips' science of dental materials. 1996quem mais cita →
- 3M Bafile, GN Graser, ML Myers e mais 1. Porosity of denture resin cured by microwave energy. J Prosthet Dent, 1991quem mais cita →
- 4JA Bartoloni, DF Murchison, DT Wofford e mais 1. Degree of conversion in denture base materials for varied polymerization techniques. J Oral Rehabil, 2000quem mais cita →
- 5KO Braun, AA Del Bel Cury e JA Cury. Use of microwave energy for processing acrylic resin near metal. Rev Odontol Univ São Paulo, 1998quem mais cita →
- 6JP Clerck. Microwave polymerization of acrylic resins used in dental prosthesis. J Prosthet Dent, 1987quem mais cita →
- 7AA Del Bel Cury, RN Rached e SM Ganzarolli. Microwave-cured acrylic resins and silicone-gypsum molding technique. J Oral Rehabil, 2001quem mais cita →
- 8A Harrison e R Huggett. Effect of the curing cycle on residual monomer levels of acrylic resin denture base polymers. J Dent, 1992quem mais cita →
- 9SG Ilbay, S Güvener e HN Alkumru. Processing dentures using a microwave technique. J Oral Rehabil, 1994quem mais cita →
- 10V Jerolimov, R Huggett, SC Brooks e mais 1. The effect of variations in the polymer/monomer mixing ratios on residual monomer levels and flexural properties of denture base materials. Quintessence Dent Technol, 1985quem mais cita →
- 11DJ Lamb, B Ellis e D Priestley. Loss into water of residual monomer from autopolymerising dental acrylic resin. Biomaterials, 1982quem mais cita →
- 12B Levin, JL Sanders e PV Reitz. The use of microwave energy for processing acrylic resins. J Prosthet Dent, 1989quem mais cita →
- 13PV Reitz, JL Sanders e B Levin. The curing of denture acrylic resins by microwave energy: Physical properties. Quintessence Int, 1985quem mais cita →
- 14RCM Rodrigues Garcia e AA Del Bel Cury. Accuracy and porosity of denture bases submitted to two polymerization cycles. Indian J Dent Res, 1996quem mais cita →
- 15S Sadamori, N Shigeto, T Hamada e mais 1. A method of determining residual monomer in acrylic resin using methyl ethyl ketone. Aust Dent J, 1990quem mais cita →
- 16JL Sanders, B Levin e PV Reitz. Comparison of the adaptation of acrylic resin cured by microwave energy and conventional water bath. Quintessence Int, 1991quem mais cita →
- 17PJ Sheridan, S Koka, NO Ewoldsen e mais 2. Cytotoxicity of denture base resins. Int J Prosthodont, 1997quem mais cita →
- 18PK Vallittu, V Miettinen e P Alakuijala. Residual monomer content and its release into water from denture base materials. Dent Mater, 1995quem mais cita →
Quem cita esta obra
1 artigo do acervo
quem fala desta obra
5 pessoas- Rafael Leonardo Xediek Consani1 artigo · 2009
- Wagner Araujo de Negreiros1 artigo · 2009
- Lecio Pitombeira Pinto1 artigo · 2009
- Antonio Materson da Silva1 artigo · 2009
- Marcus Aurelio Rabelo Lima Verde1 artigo · 2009