Durability of light wood frame constructive system: study of interstitial condensation
Arthur Ozelame e Luciana Alves Oliveira
em inglês
resumo
Abstract The Light Wood Frame (LWF) construction system has been increasingly researched and applied in Brazilian buildings, driven by the recent publication (mid-2023) of the Brazilian standard "Light Wood Frame Buildings" and by its potential for industrialization and reduced environmental impact. This reduction is mainly due to the system's ability to capture biogenic carbon through the timber used in its frames. However, a critical consideration for implementing this system in Brazilian buildings is ensuring compliance with durability requirements, particularly in addressing the risk of high humidity levels within walls or between floors, which can result from interstitial condensation. This article aims to analyze the occurrence of interstitial condensation in the walls of buildings constructed with the LWF system in the Brazilian Bioclimatic Zone 1M. To achieve this, a bibliographic review was conducted, the characteristics of the wall construction components were gathered, and computer simulations were performed using EnergyPlus and WUFI Pro 6.5 software. For the configuration studied, no interstitial condensation was detected in the internal bracing layer of the wall, suggesting a good natural drainage capacity of the construction system in the evaluated bioclimatic zone.
como citar · ABNT NBR 6023
OZELAME, Arthur; OLIVEIRA, Luciana Alves. Durability of light wood frame constructive system: study of interstitial condensation. Ambiente Construído, 2025. DOI: 10.1590/S1678-86212025000100912.
Referências
43 obras citadas
- 1AGENCIA FAPESP. Housing deficit makes “vertical isolation” impossible, Brazilian researchers say. 2020quem mais cita →
- 2AMERICAN NATIONAL STANDARDS INSTITUTE. Standard 160: criteria for moisture-control design analysis in buildings. 2021quem mais cita →
- 3AMERICAN SOCIETY FOR TESTING AND MATERIALS. E96/E96M: standard test methods for water vapor transmission of materials. 2018quem mais cita →
- 4AMERICAN WOOD COUNCIL'S. National Design Specification for Wood Construction (NDS). 2018quem mais cita →
- 5ASSOCIAÇÃO CATARINENSE DE PRODUTORES FLORESTAIS. Anuário estatístico de base florestal. ACR, 2014quem mais cita →
- 6ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 15220-3: desempenho térmico de edificações: parte 3: zoneamento bioclimático por desempenho. 2024quem mais cita →
- 7ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 15575-1: edificações habitacionais: desempenho: parte 1: requisitos gerais. 2021quem mais cita →
- 8ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 16936: edificações em light wood frame. 2023quem mais cita →
- 9AUSTRALIAN STANDARS. AS 1684.2: residential timber-framed construction: non-cyclonic areas. 2010quem mais cita →
- 10A BASTOS OZELAME. Análise de sensibilidade do uso de barreiras de vapor em sistemas de light wood frame com base na avaliação da umidade e do risco de condensação intersticial. 2023quem mais cita →
- 11BBC NEWS. Brazil flooding: at least 75 people have died and 103 are missing. 2024quem mais cita →
- 12L BELLIA e F MINICHIELLO. A simple evaluator of building envelope moisture condensation according to European Standard. Building and Environment, 2003quem mais cita →
- 13BRAZIL. Ministério das Cidades. SiNAT 001: diretriz para avaliação técnica de paredes estruturais de concreto moldadas no local (Concreto Leve ou Concreto Reforçado com Fibra de Vidro). 2022quem mais cita →
- 14BRAZIL. Ministério das Cidades. SiNAT 005: sistema estruturado em peças leves de madeira maciça serrada: tipo light wood framing. 2020quem mais cita →
- 15BRAZIL. Ministério do Desenvolvimento Regional. SINAT 2021: protocolo de avaliação de desempenho térmico de sistemas construtivos para habitações por simulações computacionais. 2021quem mais cita →
- 16BRITISH STANDARDS INSTITUTION. BS 5250: management of moisture in buildings: code of practice. 2021quem mais cita →
- 17CANADIAN GENERAL STANDARDS BOARD. vapour barrier sheet, excluding polyethylene, for use in building construction. CGSB 51.33: M89, 1989quem mais cita →
- 18COMITÉ EUROPÉEN DE NORMALISATION. CEN/TR 12872: wood-based panels: guidance on the use of load-bearing boards in floors, walls and roofs. 2014quem mais cita →
- 19EUROPEAN COMMITTEE FOR STANDARDIZATIO. Eurocode 5: design of timber structures General. EN 1995-1-1, 2004quem mais cita →
- 20EUROPEAN COMMITTEE FOR STANDARDIZATION. EN 300: Oriented Strand Boards (OSB): definitions, classification and specifications. 2006quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda