Journal of Applied Oral Science2007

Comparative study of single and multislice computed tomography for assessment of the mandibular canal

Adriana da Silva Ferreira Paes, Carla Ruffeil Moreira, Marcelo Augusto Oliveira Sales e Marcelo Gusmão Paraíso Cavalcanti

em inglês

cita 15 obras

resumo

OBJECTIVE: The purpose of this study was to evaluate the accuracy of relative measurements from the roof of the mandibular canal to the alveolar crest in multislice (multidetector) computed tomography (MDCT) and single-slice computed tomography (SSCT). MATERIAL AND METHODS: The sample consisted of 26 printed CT films (7 SSCT and 19 MDCT) from the files of the LABI-3D (3D Imaging Laboratory) of the School of Dentistry of the University of São Paulo (FOUSP), which had been acquired using different protocols. Two observers analyzed in a randomized and independent order a series of 22 oblique CT reconstructions of each patient. Each observer analyzed the CT scans twice. The length of the mandibular canal and the distance between the mandibular canal roof and the crest of the alveolar ridge were obtained. Dahlberg test was used for statistical analysis. RESULTS: The mean error found for the mandibular canal length measurements obtained from SSCT was 0.53 mm in the interobserver analysis, and 0.38 mm for both observers. On MDCT images, the mean error was 0.0 mm in the interobserver analysis, and 0.0 and 0.23 mm in the intraobserver analysis. Regarding the distance between the mandibular canal roof and the alveolar bone crest, the SSCT images showed a mean error of 1.16 mm in the interobserver analysis and 0.66 and 0.59 mm in the intraobserver analysis. In the MDCT images, the mean error was 0.72 mm in the interobserver analysis and 0.50 and 0.54 mm in the intraobserver analysis. CONCLUSION: Multislice CT was demonstrated a more accurate method and demonstrated high reproducibility in the analysis of important anatomical landmarks for planning of mandibular dental implants, namely the mandibular canal pathway and alveolar crest height.

como citar · ABNT NBR 6023

PAES, Adriana da Silva Ferreira et al. Comparative study of single and multislice computed tomography for assessment of the mandibular canal. Journal of Applied Oral Science, 2007. Disponível em: https://www.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572007000300012. Acesso em: 28 nov. 2026.

Referências

15 obras citadas

  1. 1JJ Abrahams. Anatomy of the jaw revisited with a dental CT software program. AJNR Am J Neuroradiol, 1993quem mais cita →
  2. 2A Berberi, J Mani e I Nasseh. Duplicated mandibular canal: report of a case. Quintessence Int, 1994quem mais cita →
  3. 3KJ Butterfield, M Dagenais e C Clokie. Linear tomography's clinical accuracy and validity for presurgical dental implant analysis. Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 1997quem mais cita →
  4. 4MG Cavalcanti, A Ruprecht e MW Vannier. 3D volume rendering using multislice CT for dental implants. Dentomaxillofac Radiol, 2002quem mais cita →
  5. 5MG Cavalcanti, J Yang, A Ruprecht e mais 1. Validation of spiral computed tomography for dental implants. Dentomaxillofac Radiol, 1998quem mais cita →
  6. 6AM DelBalso, FG Greiner e M Licata. Role of diagnostic imaging in evaluation of the dental implant patient. Radiographics, 1994quem mais cita →
  7. 7H Hu. Multi-slice helical CT: scan and reconstruction. Med Phys, 1999quem mais cita →
  8. 8B Klinge, A Petersson e P MALY. Location of the mandibular canal: comparison of macroscopic findings, conventional radiography, and computed tomography. Int J Oral Maxillofac Implants, 1989quem mais cita →
  9. 9X Liang, R Jacobs e I Lambrichts. An assessment on spiral CT scan of the superior and inferior genial spinal foramina and canals. Surg Radiol Anat, 2006quem mais cita →
  10. 10C Lindh, A Petersson e B Klinge. Measurements of distances related to the mandibular canal in radiographs. Clin Oral Implants Res, 1995quem mais cita →
  11. 11CH McCollough e FE Zink. Performance evaluation of a multi-slice CT system. Med Phys, 1999quem mais cita →
  12. 12M Naitoh, A Katsumata, E Nohara e mais 2. Measurement accuracy of reconstructed 2-D images obtained by multi-slice helical computed tomography. Clin Oral Implants Res, 2004quem mais cita →
  13. 13L Preda, EM Di Maggio, R Dore e mais 3. Use of spiral computed tomography for multiplanar dental reconstruction. Dentomaxillofac Radiol, 1997quem mais cita →
  14. 14M Prokop. Multislice CT: technical principles and future trends. Eur Radiol, 2003quem mais cita →
  15. 15MS Schwarz, SL Rothman, N Chafetz e mais 1. Computed tomography in dental implantation surgery. Dent Clin North Am, 1989quem mais cita →

Quem cita esta obra

nenhum artigo do acervo cita esta obra — ainda