The implication of initial 24-core transrectal prostate biopsy protocol on the detection of significant prostate cancer and high grade prostatic intraepithelial neoplasia

Michael Nomikos, Ioannis Karyotis, Prodromos Phillipou, Charalambos Constadinides e Dimitrios Delakas

em inglês

citado por 1 artigocita 23 obras, 1 no acervo

resumo

PURPOSE: To assess the diagnostic value of an initial 24-sample transrectal ultrasound guided (TRUS) prostate biopsy protocol compared to the 10-core technique. MATERIALS AND METHODS: We retrospectively reviewed the prostate biopsy database of consecutive men undergoing prostate biopsies under local anesthesia by using the 10 (Group A) and 24 (Group B) protocols. Men were stratified according to biopsy protocol and PSA levels. Exclusion criteria were age = 75 years and PSA > 20 ng/mL. The Mann-Whitney U and Fisher's exact test were used for statistical analysis. RESULTS: Between April 2007 and August 2009, 869 men underwent TRUS prostate biopsies of which 379 were eligible for the study. Group A (10-cores) consisted of 243 (64.11%) men and group B (24-cores) included 139 (35.89%) men. The overall prostate cancer detection rate was 39.09% and 34.55% in Group A and B, respectively (p = 0.43). An overall 9.8% increase in Gleason 7 detection rate was found in Group B (p = 0.24). The high-grade prostatic intraepithelial neoplasia (HGPIN) detection rate in men with negative initial biopsies was 15.54% and 35.55% in Group A and B, respectively (p < 0.001). In patients with PSA < 10 ng/mL, the 24-core technique increased Gleason 7 detection rate by 13.4 % (p = 0.16) and HGPIN by 23.4% (p = 0.0008), compared to the 10 core technique. The 24-core technique increased the concordance between needle biopsy and prostatectomy specimen compared to 10-core technique (p < 0.002). CONCLUSIONS: The initial 24-core prostate biopsy protocol did not show any benefit in the detection of prostate cancer compared to the 10-core technique. However, it improved the HGPIN detection and the correlation between biopsy results and radical prostatectomy Gleason score in men with lower PSA levels.

como citar · ABNT NBR 6023

NOMIKOS, Michael et al. The implication of initial 24-core transrectal prostate biopsy protocol on the detection of significant prostate cancer and high grade prostatic intraepithelial neoplasia. International braz j urol, 2011. Disponível em: https://www.scielo.br/scielo.php?script=sci_arttext&pid=S1677-55382011000100011. Acesso em: 28 nov. 2026.

Referências

23 obras citadas · 1 no acervo

  1. 1KK Hodge, JE McNeal, MK Terris e mais 1. Random systematic versus directed ultrasound guided transrectal core biopsies of the prostate. J Urol, 1989quem mais cita →
  2. 2JI Epstein, PC Walsh e HB Carter. Importance of posterolateral needle biopsies in the detection of prostate cancer. Urology, 2001quem mais cita →
  3. 3JI Epstein, K Lecksell e HB Carter. Prostate cancer sampled on sextant needle biopsy: significance of cancer on multiple cores from different areas of the prostate. Urology, 1999quem mais cita →
  4. 4H Miyake, I Sakai, K Harada e mais 2. Increased detection of clinically significant prostate cancer by additional sampling from the anterior lateral horns of the peripheral zone in combination with the standard sextant biopsy. Int J Urol, 2004quem mais cita →
  5. 5SY Eskicorapci, DE Baydar, C Akbal e mais 3. An extended 10-core transrectal ultrasonography guided prostate biopsy protocol improves the detection of prostate cancer. Eur Urol, 2004quem mais cita →
  6. 6V Ficarra, G Novella, G Novara e mais 3. The potential impact of prostate volume in the planning of optimal number of cores in the systematic transperineal prostate biopsy. Eur Urol, 2005quem mais cita →
  7. 7M Inahara, H Suzuki, S Kojima e mais 3. Improved prostate cancer detection using systematic 14-core biopsy for large prostate glands with normal digital rectal examination findings. Urology, 2006quem mais cita →
  8. 8IF San Francisco, WC DeWolf, S Rosen e mais 2. Extended prostate needle biopsy improves concordance of Gleason grading between prostate needle biopsy and radical prostatectomy. J Urol, 2003quem mais cita →
  9. 9JI Epstein e M Herawi. Prostate needle biopsies containing prostatic intraepithelial neoplasia or atypical foci suspicious for carcinoma: implications for patient care. J Urol, 2006quem mais cita →
  10. 10JC Jr Presti. Prostate biopsy strategies. Nat Clin Pract Urol, 2007quem mais cita →
  11. 11L Nesrallah, A Nesrallah, AA Antunes e mais 2. The role of extended prostate biopsy on prostate cancer detection rate: a study performed on the bench. Int Braz J Urol, 2008no acervo →
  12. 12JS Jones, A Patel, L Schoenfield e mais 3. Saturation technique does not improve cancer detection as an initial prostate biopsy strategy. J Urol, 2006quem mais cita →
  13. 13V Scattoni, M Roscigno, M Raber e mais 3. Initial extended transrectal prostate biopsy--are more prostate cancers detected with 18 cores than with 12 cores?. J Urol, 2008quem mais cita →
  14. 14V Scattoni, M Raber, F Abdollah e mais 3. Biopsy schemes with the fewest cores for detecting 95% of the prostate cancers detected by a 24-core biopsy. Eur Urol, 2010quem mais cita →
  15. 15JI Epstein e SR Potter. The pathological interpretation and significance of prostate needle biopsy findings: implications and current controversies. J Urol, 2001quem mais cita →
  16. 16CK Moore, S Karikehalli, T Nazeer e mais 3. Prognostic significance of high grade prostatic intraepithelial neoplasia and atypical small acinar proliferation in the contemporary era. J Urol, 2005quem mais cita →
  17. 17Y Naya, AG Ayala, P Tamboli e mais 1. Can the number of cores with high-grade prostate intraepithelial neoplasia predict cancer in men who undergo repeat biopsy?. Urology, 2004quem mais cita →
  18. 18M Herawi, H Kahane, C Cavallo e mais 1. Risk of prostate cancer on first re-biopsy within 1 year following a diagnosis of high grade prostatic intraepithelial neoplasia is related to the number of cores sampled. J Urol, 2006quem mais cita →
  19. 19L Schoenfield, JS Jones, CD Zippe e mais 3. The incidence of high-grade prostatic intraepithelial neoplasia and atypical glands suspicious for carcinoma on first-time saturation needle biopsy, and the subsequent risk of cancer. BJU Int, 2007quem mais cita →
  20. 20BM Mian, DJ Lehr, CK Moore e mais 3. Role of prostate biopsy schemes in accurate prediction of Gleason scores. Urology, 2006quem mais cita →
1–20 de 23 obras citadas