Needle visualization during ultrasound-guided puncture: image optimization
Augusto Cézar Lacerda Brasileiro, Aeudson Víctor Cunha Guedes e Silva, Ariana Lacerda Garcia, Beatriz Ribeiro Coutinho de Mendonça Furtado, Frederico Augusto Polaro Araújo Filho, Laís Nóbrega Diniz, Leonardo César Maia e Silva e Lorena Agra da Cunha Lima
em inglês
resumo
Abstract Background Obtaining an adequate image of the needle by ultrasound reduces complications resulting from punctures, increasing patient safety and reducing hospitalization costs. Objectives To verify human perception in relation to number of pixels, while also identifying the best puncture angle and which needle should be used, and to evaluate whether there is a difference if needle visualization software is used. Methods 20 images were analyzed by 103 students who classified them as being sufficient or insufficient and were compared with the quality observed using photoshop. We evaluated whether there were differences between puncture angles of less than 45º and more than 45º, between IV catheter and introducer needles, and between images obtained with and without visualization software. Results There was a higher percentage of sufficient ratings for images those that had more than 60 pixels and when the puncture angle was less than 45º, with significant associations between students’ evaluations and each of these groups (p < 0.001). The percentages of images classified as sufficient were higher for images in which a IV catheter was used and also higher for those using the needle visualization software, with significant associations between the results for students’ classifications and each of these groups (p < 0.001). Conclusions The human eye classifies an image as sufficient according to higher numbers of pixels. Images of punctures at angles smaller than 45º in relation to the surface, of punctures performed with a IV catheter, and when using specific visualization software are also better detected by the human eye.
como citar · ABNT NBR 6023
BRASILEIRO, Augusto Cézar Lacerda et al. Needle visualization during ultrasound-guided puncture: image optimization. Jornal Vascular Brasileiro, 2023. DOI: 10.1590/1677-5449.202300382.
Referências
18 obras citadas · 1 no acervo
- 1Y Seleznova, P Brass, M Hellmich e mais 2. Cost-effectiveness-analysis of ultrasound guidance for central venous catheterization compared with landmark method: a decision-analytic model. BMC Anesthesiol, 2019quem mais cita →
- 2GA Chapman, D Johnson e AR Bodenham. Visualisation of needle position using ultrasonography. Anaesthesia, 2006quem mais cita →
- 3BD Sites, R Brull e VW Chan. Artifacts and pitfall errors associated with ultrasound-guided regional anesthesia. Part I: understanding the basic principles of ultrasound physics and machine operations. Reg Anesth Pain Med, 2007quem mais cita →
- 4HJ Scholten, A Pourtaherian, N Mihajlovic e mais 2. Improving needle tip identification during ultrasound-guided procedures in anaesthetic practice. Anaesthesia, 2017quem mais cita →
- 5B Saugel, TWL Scheeren e JL Teboul. Ultrasound-guided central venous catheter placement: a structured review and recommendations for clinical practice. Crit Care, 2017quem mais cita →
- 6M Lamperti, DG Biasucci e N Disma. European Society of Anaesthesiology guidelines on peri-operative use of ultrasound-guided for vascular access. Eur J Anaesthesiol, 2020quem mais cita →
- 7KJ Chin, A Perlas, VW Chan e mais 1. Needle visualization in ultrasound-guided regional anesthesia: challenges and solutions. Reg Anesth Pain Med, 2008quem mais cita →
- 8I Schafhalter-Zoppoth, CE McCulloch e AT Gray. Ultrasound visibility of needles used for regional nerve block: an in vitro study. Reg Anesth Pain Med, 2004quem mais cita →
- 9J Takatani, N Takeshima, K Okuda e mais 3. Enhanced Needle Visualization: advantages and indications of an ultrasound software package. Anaesth Intensive Care, 2012quem mais cita →
- 10FM Luz, VRD Yacoub, KAA Silveira e mais 2. A model for training ultrasound-guided fine-needle punctures. Rev Assoc Med Bras, 2022no acervo →
- 11Y Kobayashi, R Hamano e H Watanabe. Preliminary in vivo evaluation of a needle insertion manipulator for central venous catheterization. Robomech J., 2014quem mais cita →
- 12M Miura, K Takeyama e T Suzuki. Visibility of ultrasound-guided echogenic needle and its potential in clinical delivery of regional anesthesia. Tokai J Exp Clin Med, 2014quem mais cita →
- 13JL Kendall e JP Faragher. Ultrasound-guided central venous access: a homemade phantom for simulation. CJEM, 2007quem mais cita →
- 14J Kline. Reliable needle visualization during ultrasound guided regional and vascular procedures: a simple solution to steep angle echogenicity loss with any ultrasound system, based on target depth. Anesthesia Journal., 2015quem mais cita →
- 15B Bai, Y Tian, Y Zhang e mais 2. Dynamic needle tip positioning versus the angle-distance technique for ultrasound guided radial artery cannulation in adults: a randomized controlled trial. BMC Anesthesiol, 2020quem mais cita →
- 16G Reusz, P Sarkany, J Gal e mais 1. Needle-related ultrasound artifacts and their importance in anaesthetic practice. Br J Anaesth, 2014quem mais cita →
- 17K Nichols, LB Wright, T Spencer e mais 1. Changes in ultrasonographic echogenicity and visibility of needles with changes in angles of insonation. J Vasc Interv Radiol, 2003quem mais cita →
- 18T Maecken, M Zenz e T Grau. Ultrasound characteristics of needles for regional anesthesia. Reg Anesth Pain Med, 2007quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda