Jornal Vascular Brasileiro2015
Real time echo-guided endolaser for thermal ablation without perivenous tumescence
Ricardo José Gaspar, André Nóbrega Castro, Manuel de Jesus Simões e Hélio Plapler
em inglês
resumo
Abstract Background There is no consensus in the medical literature on the ideal procedure for endovenous laser application. Objective To assess the safety and efficacy of real time echo-guided endovenous laser for thermal ablation of great saphenous vein (GSV) incompetence, without perivenous tumescence. Methods Thirty-four limbs of patients with CEAP clinical scores of 2 to 6 and bilateral incompetence of the saphenofemoral junction (SFJ) and GSV, confirmed by Echo-Doppler, underwent endovenous laser therapy and were followed for 1 year. Laser ablation was performed using a 600 µ bare optical fiber introduced endovenously close to the malleolus along the full extent of the GSV in an anterograde direction, using a standardized echo-Doppler-guided AND? 15 watt continuous mode 980 nm diode laser with real-time monitoring of thermal ablation of the whole target vein. Adverse effects and complications were recorded. Results Hyperesthesia, cellulitis, and fibrous cord, all transitory, developed in 2.9% of the 34 limbs treated; 8.8% developed hypoesthesia in the perimalleolar region, which was transitory and had no clinical consequences; there were no cases of deep venous thrombosis. Immediate occlusion was achieved in 100% of the 34 saphenous veins that underwent photocoagulation, although one exhibited recanalization without reflux at 1-month follow-up. After 6 months and 1 year, occlusion was 100% according to echo-Doppler findings. Conclusions Real-time echo-guided 980 nm endovenous laser ablation without perivenous tumescence provided controlled thermal ablation with safe, effective, immediate and medium-term GSV occlusion and can therefore be recommended as a method for the treatment of chronic venous disease.
como citar · ABNT NBR 6023
GASPAR, Ricardo José et al. Real time echo-guided endolaser for thermal ablation without perivenous tumescence. Jornal Vascular Brasileiro, 2015. DOI: 10.1590/1677-5449.07214.
Referências
32 obras citadas · 2 no acervo
- 1TM Proebstle, T Moehler, D Gul e mais 1. Endovenous treatment of the great saphenous vein using a 1,320 nm Nd:YAG laser causes fewer side effects than using a 940 nm diode laser. Dermatol Surg, 2005quem mais cita →
- 2TM Proebstle, HA Lehr e A Kargl. Endovenous treatment of the greater saphenous vein with a 940-nm diode laser: thrombotic occlusion after endoluminal thermal damage by laser-generated steam bubbles. J Vasc Surg, 2002quem mais cita →
- 3RG Bush. Regarding “Endovenous treatment of the greater saphenous vein with a 940-nm diode laser: thrombolytic occlusion after endoluminal thermal damage by laser-generated steam bubbles”. J Vasc Surg, 2003quem mais cita →
- 4HS Kim, IJ Nwankwo, K Hong e mais 1. Lower energy endovenous laser ablation of the great saphenous vein with 980 nm diode laser in continuous mode. Cardiovasc Intervent Radiol, 2006quem mais cita →
- 5B Palmieri, A Lapilli e G Benuzzi. Endoluminal diode laser vein damage: preclinic study for vein insufficiency. Minerva Cardioangiol, 2003quem mais cita →
- 6TM Proebstle, M Sandhofer e A Kargl. Thermal damage of the inner vein wall during endovenous laser treatment: key role of energy absorption by intravascular blood. Dermatol Surg, 2002quem mais cita →
- 7P Perkowski, R Ravi e RC Gowda. Endovenous laser ablation of the saphenous vein for treatment of venous insufficiency and varicose veins: early results from a large single-center experience. J Endovasc Ther, 2004quem mais cita →
- 8B Campbell. New treatments for varicose veins. BMJ, 2002quem mais cita →
- 9M Lefebvre-Vilardebo. The sapheno-femoral area: anatomic study and concepts for the prevention of varicose recurrences. J Mal Vasc, 1991quem mais cita →
- 10RJ Min, SE Zimmet, MN Isaacs e mais 1. Endovenous laser treatment of the incompetent greater saphenous vein. J Vasc Interv Radiol, 2001quem mais cita →
- 11L Navarro, RJ Min e C Bone. Endovenous laser: a new minimally invasive method of treatment for varicose veins--preliminary observations using an 810 nm diode laser. Dermatol Surg, 2001quem mais cita →
- 12MP Goldman, M Mauricio e J Rao. Intravascular 1320-nm laser closure of the great saphenous vein: a 6- to 12-month follow-up study. Dermatol Surg, 2004quem mais cita →
- 13AP Hingorani, E Ascher e N Markevich. Deep venous thrombosis after radiofrequency ablation of greater saphenous vein: a word of caution. J Vasc Surg, 2004quem mais cita →
- 14TM Proebstle, F Krummenauer, D Gul e mais 1. Nonocclusion and early reopening of the great saphenous vein after endovenous laser treatment is fluence dependent. Dermatol Surg, 2004quem mais cita →
- 15P Gloviczki. Endovenous treatment of varicose veins: credentialing, quality control and education. Endovascular Today., 2004quem mais cita →
- 16FHA Maffei. Diagnóstico clínico das doenças venosas periférica. Doenças vasculares periféricas, 2002quem mais cita →
- 17L Corcos, S Dini e D Anna. The immediate effects of endovenous diode 808-nm laser in the greater saphenous vein: morphologic study and clinical implications. J Vasc Surg, 2005quem mais cita →
- 18TM Proebstle, T Moehler e S Herdemann. Reduced recanalization rates of the great saphenous vein after endovenous laser treatment with increased energy dosing: definition of a threshold for the endovenous fluence equivalent. J Vasc Surg, 2006quem mais cita →
- 19C Boné Salat. Tratamiento endoluminal de las varices con láser de diodo: estudio preliminar. Rev Patol Vasc., 1999quem mais cita →
- 20RG Bush, HN Shamma e K Hammond. Histological changes occurring after endoluminal ablation with two diode lasers (940 and 1319 nm) from acute changes to 4 months. Lasers Surg Med, 2008quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda