Jornal Vascular Brasileiro2014
Comparison between the conventional method and a portable device for determination of INR
André Camacho Oliveira Araújo, Rodrigo Borges Domingues e Bonno van Bellen
em inglês
resumo
CONTEXT:Anticoagulation with warfarin is considered the appropriate treatment for venous thromboembolism and other thrombotic pathologies. Regular INR control is required for dosage adjustment and therapeutic control. Use of portable monitoring systems optimizes management of these patients.OBJECTIVE: To compare INR measurements taken using the portable Coaguchek XS system in capillary blood with the standard laboratory method using venous blood.METHOD: Fifty-two samples each of venous and capillary blood were collected from nineteen patients on warfarin, who had been admitted to the Hospital da Beneficência Portuguesa de São Paulo, and analyzed using the conventional method and the Coaguchek XS system, respectively.RESULTS: Spearman's correlation coefficient ® for the overall performance of the two methods was 0.978 (p<0.0001; 95%CI 0.961-0.988). The Kappa measure of agreement for all patients was 76.8% (p<0.001; IC: 95% 0.975-0.561). Mean INR according to the Coaguchek XS system underestimated the values provided by the conventional method by -0.01 INR points, with a standard error of 0.342. Results for INR values greater than 3.5 were satisfactory with a correlation coefficient of 0.71, but without statistical significance (p>0.714).CONCLUSIONS: The Coaguchek XS system can be used to monitor prothrombin time in patients on oral anticoagulants, provided INR values greater than 3.5 are confirmed using the conventional laboratory method.
como citar · ABNT NBR 6023
ARAÚJO, André Camacho Oliveira; DOMINGUES, Rodrigo Borges; VAN BELLEN, Bonno. Comparison between the conventional method and a portable device for determination of INR. Jornal Vascular Brasileiro, 2014. DOI: 10.1590/JVB.2014.051.
Referências
15 obras citadas · 2 no acervo
- 1S Kitchen e FE Preston. Standardization of prothrombin time for laboratory control of oral anticoagulant therapy. Semin Thromb Haemost, 1999quem mais cita →
- 2J Hirsh, JE Dalen e DR Anderson. Oral anticoagulants: mechanism of action, clinical effectiveness, and optimal therapeutic range. Chest, 1998quem mais cita →
- 3W Plesch, T Wolf e N Breitenbeck. Results of the performance verification of the Coaguchek XS system. Thromb Res, 2008quem mais cita →
- 4M Connock, C Stevens, A Fry-Smith e mais 3. Clinical effectiveness and cost-effectiveness of different models of managing long-term oral anticoagulation therapy: a systematic review and economic modeling. Health Technol Assess, 2007quem mais cita →
- 5M Donaldson, J Sullivan e A Norbeck. Comparison of international normalized ratios provided by two point-of-care devices and laboratory-based venipuncture in a pharmacist-managed anticoagulation clinic. Am J Health System Pharm, 2010quem mais cita →
- 6VK Williams e AB Griffiths. Acceptability of Coaguchek S and Coaguchek XS generated international normalized ratios against a laboratory standard in paediatric setting. Pathology, 2007quem mais cita →
- 7ZM Meneghelo, IL Liporace e PP Nunes. Comparação dos níveis do tempo de protrombina, obtidos pelo monitor portátil CoaguChek XS e técnica padrão, em pacientes ambulatoriais usando anticoagulante oral. Instituto Dante Pazzanese de Cardiologia, 2009quem mais cita →
- 8Comissão Nacional de Incorporação de Tecnologias no SUS - CONITEC. Coaguchek XS no monitoramento do INR em pacientes recebendo tratamento com varfarina. 2012quem mais cita →
- 9LPA De Piano, CMC Strunz, ADP Mansur e mais 1. Comparação entre os resultados do índice de normalização internacional medidos em dispositivo portátil (Hemochron Jr.) e por metodologia convencional. Arq Bras Cardiol, 2007no acervo →
- 10TLL Leiria, LC Pellanda, E Magalhães e mais 1. Controle do tempo de anticoagulação oral: correlação e concordância. Arq Bras Cardiol, 2007no acervo →
- 11JM Bland e DG Altman. Measuring agreement in method comparison studies. Stat Methods Med Res, 1999quem mais cita →
- 12C Heneghan, W Alison e P Rafael. The self-Monitoring Trialist Collaboration. Self-monitoring of oral anticoagulation: a systematic review and meta-analysis of individual patient data. Lancet, 2011quem mais cita →
- 13BM David, J Alan e D Rowena. THINRS Trial: Effect of Home Testing of International Normalized Ratio on Clinical Events. New Engl J Med, 2010quem mais cita →
- 14G DeSantis, J Hogan-Schlientz e G Liska. Real-world weekly INR Testing of 4,550 patients. 2012quem mais cita →
- 15H Anne, S Sam e MW Daniel. Evidence-based management of anticoagulant therapy: antithrombotic therapy and prevention of thrombosis, 9th ed: American College of Chest Physicians evidence-based clinical practice guideline. Chest, 2012quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda