AIM: Cone beam computed tomography (CBCT) was used to evaluate the ability of three NiTi rotary systems to maintain the original root canal anatomy. METHODS: Sixty mesiobuccal canals of human mandibular first molars were divided into three groups with 20 root canals each. All teeth were scanned by CBCT before instrumentation. The images were captured digitally for further analysis using the Image Tools Software. The images were sectioned in three points, located at 9 mm, 6 mm and 3mm from the apex. In Group 1, the root canals were instrumented with ProTaper UniversalTM rotary system; in Group 2, with Twisted FileTM rotary system; and in Group 3, with MtwoTM rotary system. Instrumented teeth were scanned again using CBCT and the images of the uninstrumented canals were compared with images of the instrumented canals. The results were statistically analyzed using the one-way ANOVA test. A level of significance of 0.05 was adopted. RESULTS: The means of D1 at distances of 9 mm, 6 mm, and 3 mm from the apex were, respectively: Group 1: 0.88±0.257, 1.00±0.000, and 1.00±0.000; Group 2: 0.79±0.745, 0.65±0.669, and 0.25±0; Group 3: 0.50±0.745, 0.33±0.472, and 0.03±0.104. The means of D2 at distances of 9 mm, 6mm, and 3mm from the apex were respectively: Group 1: 1.00±0.00, 1.00±0.00, and 1.00±0.00; Group 2: 0.41±0.299, 0.30±0.428, and 0.50±0.707; Group 3: 0.58±0.910, 0.85±1.857, and 0.31±0.643. CONCLUSIONS: The CBCT analysis revealed that the ProTaper UniversalTM produced centered preparations and while the Twisted FileTM and MtwoTM rotary systems produced canal deviation.

como citar · ABNT NBR 6023

AGUIAR, Carlos Menezes et al. Changes in root canal anatomy using three nickel-titanium rotary system: a cone beam computed tomography analysis. Brazilian Journal of Oral Sciences, 2013. Disponível em: https://www.scielo.br/scielo.php?script=sci_arttext&pid=S1677-32252013000400006. Acesso em: 28 nov. 2026.

Referências

36 obras citadas · 1 no acervo

  1. 1R Gergi, JA Rjeily, J Sader e mais 1. Comparison of canal transportation and centering ability of Twisted Files, Pathfile-ProTaper system, and stainless steel hand k-files by using computed tomography. J Endod, 2010quem mais cita →
  2. 2A El Ayouti, E Dima, MS Judenhofer e mais 2. Increased apical enlargement contributes to excessive dentin removal in curved root canals: a stepwise microcomputed tomography study. J Endod, 2011quem mais cita →
  3. 3AC Câmara, CM Aguiar e JAP de Figueiredo. Assessment of the deviation after biomechanical preparation of the coronal, middle, and apical thirds of root canals instrumented with three Hero rotary systems. J Endod, 2007quem mais cita →
  4. 4CM Aguiar, D de A Mendes, AC Câmara e mais 1. Assessment of canal walls after biomechanical preparation of root canals instrumented with ProTaper UniversalTM rotary system. J Appl Oral Sci, 2009no acervo →
  5. 5D de A Mendes, CM Aguiar e AC Câmara. Comparison of the centering ability of the ProTaper Universal, ProFile and Twisted File Rotary Systems. Braz J Oral Sci, 2011quem mais cita →
  6. 6GÇ Ünal, M Maden, A Savgat e mais 1. Comparative investigation of 2 rotary nickel-titanium instruments: ProTaper Universal versus ProTaper. Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 2009quem mais cita →
  7. 7HC Kim, J Yum, B Hur e mais 1. Cyclic fatigue and fracture characteristics of ground and twisted nickel-titanium rotary files. J Endod, 2010quem mais cita →
  8. 8CM Larsen, I Watanabe, GN Glickman e mais 1. Cyclic fatigue analysis of a new generation of nickel titanium rotary instruments. J Endod, 2009quem mais cita →
  9. 9G Yang, G Yuan, X Yun e mais 3. Effects of Mtwo versus ProTaper Universal, on root canal geometry assessed by micro-computed tomography. J Endod, 2011quem mais cita →
  10. 10F Foschi, C Nucci, L Montebugnoli e mais 4. SEM evaluation of canal wall dentine following use of Mtwo and ProTaper NiTi rotary instruments. Int Endod J, 2004quem mais cita →
  11. 11ES Hin, MK Wu, PR Wesswlink e mais 1. Effects of self-adjusting file, Mtwo, and ProTaper. J Endod, 2013quem mais cita →
  12. 12RA Bernardes, EA Rocha, MAH Duarte e mais 4. Root canal area increase promoted by the EndoSequence and ProTaper systems: comparison by computed tomography. J Endod, 2010quem mais cita →
  13. 13M Günday, H Sazak e Y Garip. A Comparative study of three different root canal curvature measurement techniques and measuring the canal access angle in curved canals. J Endod, 2005quem mais cita →
  14. 14CM Sanfelice, FB da Costa, MVR Só e mais 3. Effects of four instruments on coronal pre-enlargement by using cone beam computed tomography. J Endod, 2010quem mais cita →
  15. 15JM Gambill, M Alder e CE Del Rio. Comparison of nickel-titanium and stainless steel hand-file instrumentation using computed tomography. J Endod, 1996quem mais cita →
  16. 16S Stern, S Patel, F Foschi e mais 2. Changes in centring and shaping ability using three nickel-titanium instrumentation techniques analysed by micro-computed tomography (µCT). Int Endod J, 2012quem mais cita →
  17. 17N Venkateshbabu, S Emmanuel, GK Santosh e mais 1. Comparison of the canal centring ability of K3, Liberator and EZ Fill Safesiders by using spiral computed tomography. Aust Endod J, 2012quem mais cita →
  18. 18GB Sydney, A Batista e LL De Mello. The radiographic platform: a new method to evaluate root canal preparation in vitro. J Endod, 1991quem mais cita →
  19. 19B Pasternak-Júnior, MD Sousa-Neto e RG Siva. Canal transportation and centring ability of RaCe Rotary instruments. Int Endod J, 2009quem mais cita →
  20. 20CB Flores, P Machado, F Montagner e mais 3. A methodology to standardize the evaluation of root canal instrumentation using cone beam computed tomography. Braz J Oral Sci, 2012quem mais cita →
1–20 de 36 obras citadas

Quem cita esta obra

nenhum artigo do acervo cita esta obra — ainda