Jornal Brasileiro de Patologia e Medicina Laboratorial2016
Polymethyl methacrylate (Linnea Safe) causes local inflammatory response after intramuscular implant in BALB/c mice but it is not observed in distant organs
Eduardo Luiz Costa, Anália C. Milhomem, Ronaldo Moisés de Moura Filho e Ruy S. Lino Jr.
em inglês
resumo
ABSTRACT Introduction: Among its different therapeutic functions, the use of polymethyl methacrylate (PMMA) for more than a decade has has stood out in the replacement of the volumes lost with the aging process and filling in wrinkles and creases. It is considered a permanent biomaterial despite its reliability is widely discussed by health professionals. Objective: To analyze the size of the microspheres in of three different commercialized types of PMMA, and the inflammatory process generated by the implant, as well as to evaluate possible migration of the microspheres. Methods: The polymers of the brands Biossimetric®, MetaCrill® and Linnea Safe® were analyzed by scanning electron microscope (SEM) and had the dispersion and the size of its particles determined. After this analysis, it was decided to implant in BALB/c mice the polymer of the brand Linnea Safe®, which was the more homogeneous product. The animals submitted to polymer implantation were euthanized at 3, 7, 15, 30, 60, 90 and 120 days after implantation, allowing the weighing of the implanted paws and the histopathological analysis of some tissues. Results: It was observed that the implantation of Linnea Safe® PMMA microspheres in mice triggered an acute inflammatory process 3 to 15 days after the surgical procedure, evolving to chronic non-granulomatous inflammation with collagen deposition, tissue reorganization after 30 days of PMMA implantation up to 120 days; also, no microspheres were observed in distant organs. Conclusion: The Linnea Safe® PMMA behaved as a safe and stable biomaterial, once its microspheres were sized to prevents phagocytosis, and leads to local and controlled inflammation.
como citar · ABNT NBR 6023
COSTA, Eduardo Luiz et al. Polymethyl methacrylate (Linnea Safe) causes local inflammatory response after intramuscular implant in BALB/c mice but it is not observed in distant organs. Jornal Brasileiro de Patologia e Medicina Laboratorial, 2016. DOI: 10.5935/1676-2444.20160058.
Referências
20 obras citadas · 3 no acervo
- 1G Lemperle, H Ott, U Charrier e mais 2. PMMA microspheres for intradermal implantation: part I. Animal research. Ann Plastic Surg, 1991quem mais cita →
- 2LR Cardona, M Brousse e M Mieres. Evaluación de la resistencia de un prototipo de placa de compresión dinámica (PCD) fabricada de polimetilmetacrilato (PMMA) probada en fémur canino osteotomizado. Rev Med Vet., 2011quem mais cita →
- 3RCC Abdo Filho, TM Oliveira, NL Neto e mais 2. Reconstruction of bony facial contour deficiencies with polymethylmethacrylate implants: case report. J Appl Oral Sci, 2010quem mais cita →
- 4AP Oriá, FAD Neto e LA Santos. Evaluation of polymethylmethacrylate as ocular implant in rabbits subjected to evisceration. Rev Ceres, 2012no acervo →
- 5G Lemperle, TN Knapp, NS Sadick e mais 1. ArteFill(r) permanent injectable for soft tissue augmentation: I. Mechanism of action and injection techniques. Aesthetic Plast Surg, 2010quem mais cita →
- 6G Lemperle, NS Sadick, TN Knapp e mais 1. ArteFill(r) permanent injectable for soft tissue augmentation II: indications and applications. Aesthetic Plast Surg, 2010quem mais cita →
- 7E Puricelli, AM Nácul, D Ponzoni e mais 3. Intramuscular 30% polymethylmethacrylate (PMMA) implants in a non-protein vehicle: an experimental study in rats. Rev Bras Cir Plast, 2011no acervo →
- 8GS Padilha, V Mansanares e JR Bartoli. Effect of plasma fluorination variables on the deposition and growth of partially fluorinated polymer over PMMA films. Polímeros, 2013no acervo →
- 9LP Sturm, RD Cooter, KL Mutimer e mais 2. A systematic review of dermal fillers for age-related lines and wrinkles. ANZ J Surg, 2011quem mais cita →
- 10G Lemperle, N Gauthier-Hazan e M Wolters. Komplikationen nach faltenunterspritzung und ihre behandlung. Handchir Mikrochir Plast Chir, 2006quem mais cita →
- 11LH Jesus, LC Hildebrand, MD Martins e mais 3. Location of injected polymethylmethacrylate microspheres influences the onset of late adverse effects: an experimental and histopathologic study. Clin Cosmet Investig Dermatol, 2015quem mais cita →
- 12V Morhenn, G Lemperle e R Gallo. Phagocytosis of different particulate dermal filler substances by human macrophages and skin cells. Dermatol Surg, 2002quem mais cita →
- 13G Lemperle, V Morhenn, V Pestonjamasp e mais 1. Migration studies and histology of injectable microspheres of different sizes in mice. Plast Reconstr Surg, 2004quem mais cita →
- 14G Lemperle e N Gauthier-Hazan. Foreign body granulomas after all injectable dermal fillers: Part 2. Treatment options. Plast Reconstr Surg, 2009quem mais cita →
- 15G Lemperle, V Morhenn e U Charrier. Human histology and persistence of various injectable filler substances for soft tissue augmentation. Aesthetic Plast Surg, 2003quem mais cita →
- 16EM Sousa, EL Costa, EB Silva e mais 3. Resposta inflamatória e deposição de colágeno após implante intramuscular após implante intramuscular com polimetilmetacrilato em camundongos Balb/c. Acta Sci Vet, 2008quem mais cita →
- 17D Piacquadio, S Smith e R Anderson. A comparison of commercially available polymethylmethacrylate-based soft tissue fillers. Dermatol Surg, 2008quem mais cita →
- 18M Hata, J Machi e J Mamou. Entire-volume serial histological examination for detection of micrometastasis in lymph nodes of colorectal cancers. Pathol Oncol Res, 2011quem mais cita →
- 19G Landi, M Polverelli e G Moscatelli. Sentinel lymph node biopsy in patients with primary cutaneous melanoma: study of 455 cases. J Eur Acad Dermatol Venereol, 2000quem mais cita →
- 20D Grabau, L Rden, M Ferno e mais 1. Analysis of sentinel node biopsy - a single - institution experience supporting the use of serial sectioning and immunohistochemistry for detection of micrometastases by comparing four different histopathological laboratory protocols. Histopathology, 2011quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda