Brazilian Journal of Biology2021
Optimized broad-range real-time PCR-based method for bacterial screening of platelet concentrates
F. Alexandrino, J. S. Malgarin, M. A. Krieger e L. G. Morello
em inglês
resumo
Abstract Bacterial contamination of blood components remains a major challenge in transfusion medicine, particularly, platelet concentrates (PCs) due to the storage conditions that support bacterial proliferation. In this study, we develop a rapid, sensitive and specific real-time PCR protocol for bacterial screening of PCs. An internally controlled real-time PCR-based method was optimized and validated with our proprietary 16S Universal PCR Master Mix (IBMP/Fiocruz), which targets a conserved region of the bacterial 16S rRNA gene. Nonspecific background DNA was completely eliminated by treating the PCR Master Mix with ethidium monoazide (EMA). A lower limit of detection was observed for 10 genome equivalents with an observed Ct value of 34±1.07 in calibration curve generated with 10-fold serial dilutions of E. coli DNA. The turnaround time for processing, including microbial DNA purification, was approximately 4 hours. The developed method showed a high sensitivity with no non-specific amplification and a lower time-to-detection than traditional microbiological methods, demonstrating it to be an efficient means of screening pre-transfusion PCs.
como citar · ABNT NBR 6023
ALEXANDRINO, F. et al. Optimized broad-range real-time PCR-based method for bacterial screening of platelet concentrates. Brazilian Journal of Biology, 2021. DOI: 10.1590/1519-6984.229893.
Referências
46 obras citadas
- 1G. ALBERTONI, S.S. ANDRADE, P.R.B. ARAUJO e mais 3. Evaluation of two detection methods of microorganisms in platelet concentrates. Transfusion Medicine (Oxford, England), 2011quem mais cita →
- 2B. ANDERSON. Broad-range polymerase chain reaction for detection and identification of bacteria. The Journal of the Florida Medical Association, 1994quem mais cita →
- 3D.A. ARMBRUSTER, M.D. TILLMAN e L.M. HUBBS. Limit of detection (LOD)/limit of quantification (LOQ): comparison of the empirical and the statistical methods exemplified with GC-MS assays of abused drugs. Clinical Chemistry, 1994quem mais cita →
- 4R.J. BENJAMIN e S.J. WAGNER. The residual risk of sepsis: modelling the effect of concentration on bacterial detection in two-bottle culture systems and an estimation of false negative culture rates. Transfusion, 2007quem mais cita →
- 5M.A. BLAJCHMAN. Incidence and significance of the bacterial contamination of blood components. Developmental Biology, 2002quem mais cita →
- 6M.A. BLAJCHMAN, E.A. BECKERS, E. DICKMEISS e mais 3. Bacterial detection of platelets: current problems and possible resolutions. Transfusion Medicine Reviews, 2005quem mais cita →
- 7M.A. BLAJCHMAN, M. GOLDMAN e F. BAEZA. Improving the bacteriological safety of platelet transfusions. Transfusion Medicine Reviews, 2004quem mais cita →
- 8M.E. BRECHER, S.N. HAY e S.J. ROTHENBERG. Monitoring of apheresis platelet bacterial contamination with an automated liquid culture system: a university experience. Transfusion, 2003quem mais cita →
- 9R. BRUHN, B. CUSTER, S. VANDERPOOL e mais 3. Impact of increasing sample volume from 4 ml to 8 ml on bacterial detection rates in apheresis platelets: a metaanalysis. Vox Sanguinis, 2015quem mais cita →
- 10M. BURNS e H. VALDIVIA. Modelling the limit of detection in real-time quantitative PCR. European Food Research and Technology, 2008quem mais cita →
- 11S.A. BUSTIN, V. BENES, J.A. GARSON e mais 9. The MIQE guidelines: minimum information for publication of quantitative real-time PCR experiments. Clinical Chemistry, 2009quem mais cita →
- 12C.E. CORLESS, M. GUIVER, R. BORROW e mais 3. Contamination and sensitivity issues with a real-time universal 16S rRNA PCR. Journal of Clinical Microbiology, 2000quem mais cita →
- 13S. DAS, M. KALE, P.M. BEENA e mais 1. Bacterial contamination of platelet at University Hospital: “A prospective surveillance study. INSS, 2015quem mais cita →
- 14I. DOBBELAER, S. NEERKEN, P. VAN DE WIEL e mais 2. Selective lysis of cells by ionic surfactants. 2012quem mais cita →
- 15D.J. ECKER, R. SAMPATH, H. LI e mais 9. New technology for rapid molecular diagnosis of bloodstream infections. Expert Review of Molecular Diagnostics, 2010quem mais cita →
- 16M.A. ESMAILI, F. RAZJOU e B.N. KHOSROSHAHI. Evaluations of detections methods of bacterial contamination in platelet components. International Journal of Medical Laboratory, 2017quem mais cita →
- 17S. EZUKI, K. KAWABATA, T. KANNO e mais 1. Culture-based bacterial detection systems for platelets: the effect of time prior to sampling and duration of incubation required for detection with aerobic culture. Transfusion, 2007quem mais cita →
- 18R.A. FISHER. Statistical methods for research workers. 1956quem mais cita →
- 19J.A. GARSON, P. PATEL, C. MCDONALD e mais 6. Evaluation of an ethidium monoazide-enhanced 16S rDNA real-time polymerase chain reaction assay for bacterial screening of platelet concentrates and comparison with automated culture. Transfusion, 2014quem mais cita →
- 20I. HEIN, W. SCHNEEWEISS, C. STANEK e mais 1. Ethidium monoazide and propidium monoazide for elimination of unspecific DNA background in quantitative universal real-time PCR. Journal of Microbiological Methods, 2007quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda