Marcelo Augusto Assunção Sanches, Ruberlei Gaino, Renan Fernandes Kozan, Marcelo Carvalho Minhoto Teixeira, Aparecido Augusto de Carvalho, Márcio Roberto Covacic, Carlos Antonio Alves, Mateus Fernandes Réu Urban, Marcos Vinícius Nascimento Junqueira, Rodrigo Cardim, Edvaldo Assunção e Edno Gentilho Junior
em inglês
resumo
INTRODUCTION: A methodology was developed for implementing closed-loop control algorithms and for evaluating the behavior of a system, considering certain component restrictions used in laboratory implementation. METHODS: Mathematical functions representing a model of the biological system were used for knee extension/flexion movements. A Proportional Integral Derivative (PID) controller and another one using the root locus method were designed to control a patient’s leg position by applying functional electrical stimulation (FES). The controllers were simulated in Matlab and ISIS Proteus. After the simulations were performed, the codes were embedded in a microcontroller, and tests were conducted on a paraplegic volunteer. To the best of the authors’ knowledge, this is the first time that ISIS Proteus software resources have been used prior to implementing a closed-loop system designed to control the leg position of patients. RESULTS:This method obviates the application of initial controller tests directly to patients. The response obtained in the experiment with a paraplegic patient complied with the specifications set in terms of the steady-state error, the settling time, and the percentage overshoot. The proposed procedure was successfully applied for the implementation of a controller used to control the leg position of a paraplegic person by electrical muscle stimulation. CONCLUSION:The methodology presented in this manuscript can contribute to the implementation of analog and digital controllers because hardware limitations are typically not taken into account in the design of controllers.
como citar · ABNT NBR 6023
SANCHES, Marcelo Augusto Assunção et al. Digital controller design considering hardware constraints: application in a paraplegic patient. Revista Brasileira de Engenharia Biomédica, 2014. DOI: 10.1590/1517-3151.0196.
Referências
25 obras citadas
- 1G Andreoni, G Ferrigno, G Baroni e mais 3. Postural modification in microgravity. Proceedingsquem mais cita →
- 2Blog do Deficiente Físico. Resultado do Censo 2010 feito pelo IBGE sobre pessoas com deficientesquem mais cita →
- 3J Bobet e RB Stein. A simple model of force generation by skeletal muscle during dynamic isometric contractions. IEEE Transactions on Biomedical Engineering, 1998quem mais cita →
- 4PE Crago, JT Mortimer e PH Peckham. Closed-loop control of force during electrical stimulation of muscle. IEEE Transactions on Biomedical Engineering, 1980quem mais cita →
- 5S Cuoghi e L Ntogramatzidis. Direct and exact methods for the synthesis of discrete time PID controllers. IET Control Theory and Applications, 2013quem mais cita →
- 6GS Deaecto. Projeto e simulações de sistemas de controle utilizando modelo fuzzy e LMIquem mais cita →
- 7M Ferrarin e A Pedotti. The relationship between electrical stimulus and joint torque: a dynamic model. IEEE Transactions on Rehabilitation Engineering, 2000quem mais cita →
- 8M Ferrarin, F Palazzo, R Riener e mais 1. Model-based control of FES-induced single joint Movements. IEEE Transactions on Neural Systems and Rehabilitation Engineering, 2001quem mais cita →
- 9GF Franklin, JD Powell e ML Workman. Digital control of dynamic systems. 2006quem mais cita →
- 10R Gaino, TI Silva, MAA Sanches e mais 7. Controle digital para fes no estímulo do músculo quadríceps em pacientes paraplégicosquem mais cita →
- 11R Gaino, AA Carvalho, MAA Sanches e mais 4. Integração de controle e instrumentação com a utilização do software proteus para controle de movimentos na reabilitação de paraplégicosquem mais cita →
- 12R Gaino. Controle de movimentos de pacientes paraplégicos utilizando modelos Fuzzy Takagi-Sugenoquem mais cita →
- 13R Gaino, MCM Teixeira, AA Carvalho e mais 4. Realimentação derivativa e modelo fuzzy Takagi-Sugeno para controle da articulação do joelho de pacientes paraplégicos com o uso de acelerômetros. Revista Brasileira de Engenharia Biomédica, 2011quem mais cita →
- 14BN Griffin. Design guide: the influence of zero-G and acceleration on the human factors of spacecraft design. 1978quem mais cita →
- 15H Hatze. Myocybernetic control models of skeletal muscle. 1981quem mais cita →
- 16AF Huxley. Muscle structure and theories of contraction. Progress in Biophysics and Biophysical Chemistry, 1957quem mais cita →
- 17LAF Law e RK Shields. Predicting human chronically paralyzed muscle force: a comparison of three mathematical models. Journal of Applied Physiology, 2006quem mais cita →
- 18RL Lieber, PD Silva e DM Daniel. Equal effectiveness of electrical and volitional strength training for quadriceps femoris muscles after anterior cruciate ligament surgery. Journal of Orthopaedic Research, 1996quem mais cita →
- 19S Mohammed, P Poignet, P Fraisse e mais 1. Lower limbs movement restoration using input-output feedback linearization and model predictive controlquem mais cita →
- 20K Ogata. Engenharia de controle moderno. 2011quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda