resumo

INTRODUCTION: Electromagnetic interference caused by electric power lines adversely affects the signals of electronic instruments, especially those with low amplitude levels. This type of interference is known as common-mode interference. There are many methods and architectures used to minimize the influence of this kind of interference on electronic instruments, the most common of which is the use of band-reject filters. This paper presents the analysis, development, prototype and test of a new reconfigurable filter architecture for biomedical instruments, aiming to reduce the common-mode interference and preserve the useful signal components in the same frequency range as that of the noise, using the technique of dynamic impedance balancing. METHODS: The circuit blocks were mathematically modeled and the overall closed-loop transfer function was derived. Then the project was described and simulated in the VHDL_AMS language and also in an electronics simulation software, using discrete component blocks, with and without feedback. After theoretical analysis and simulation results, a prototype circuit was built and tested using as input a signal obtained from ECG electrodes. RESULTS: The results from the experimental circuit matched those from simulation: a 97.6% noise reduction was obtained in simulations using a sinusoidal signal, and an 86.66% reduction was achieved using ECG electrodes in experimental tests. In both cases, the useful signal was preserved. CONCLUSION: The method and its architecture can be applied to attenuate interferences which occur in the same frequency band as that of the useful signal components, while preserving these signals.

como citar · ABNT NBR 6023

NEGRÃO, João Francisco Ribeiro et al. Electromagnetic interference reduction by dynamic impedance balancing applied to biosensors. Revista Brasileira de Engenharia Biomédica, 2013. DOI: 10.4322/RBEB.2013.030.

Referências

12 obras citadas

  1. 1EJ Berbari. Principles of electrocardiography. The Biomedical Engineering Handbook, 2000quem mais cita →
  2. 2T Degen e H Jackel. Continuous monitoring of electrode-skin impedance mismatch during bioelectric recordings. IEEE Transactions on Biomedical Engineering, 2008quem mais cita →
  3. 3D Dobrev e L Daskalov. Two-electrode biopotential amplifier with current-driven inputs. Medical & Biological Engineering & Computing, 2002quem mais cita →
  4. 4CA Grimbergen, ACM VanRijin e A Peper. A method for the measurement of individual electrode-skin interfaces and the implications of the electrode properties for preamplifier desing. Annual International Conference of the IEEE Engineering in Medicine and Biology Society: Proceedings of the 14th Annual International Conference of the IEEE Engineering in Medicine and Biology Society; 1996; Paris, 1996quem mais cita →
  5. 5Labcenter Electronics. Isis Proteus. 1989
  6. 6Mentor Graphics. Getting started with advanced MS software. 2006quem mais cita →
  7. 7JFR Negrão, JF Naviner e IS Silva. Circuit mixte d'interface reconfigurable pour applications en instrumentation médicale. JNRDM 2006: Journées Nationales du Réseau Doctoral de Microélectronique, 2006quem mais cita →
  8. 8IS Silva. Circuits mixtes reconfigurables appliqués à la mesure de signaux biomédicaux: réjection de l'interférence de mode commun. 2003quem mais cita →
  9. 9EM Spinelli, MN Martinez, MA Mayosky e mais 1. A novel fully differential biopotential ampifier with dc suppression. IEEE Transactions on Biomedical Engineering, 2004quem mais cita →
  10. 10EM Spinelli, MA Mayosky e R Pallas-Areny. A practical approach to electrode-skin impedance unbalance measurement. Transactions on Biomedical Engineering, 2006quem mais cita →
  11. 11AY Yamamoto, T Nakamura e K Kitaoka. Automatic interference controller device for eliminating the power-line interference in biopotential signals. IMTC 2000, 2000quem mais cita →
  12. 12RM Volpato e GVB Magalhães. Método para a medição de balanceamento longitudinal em terminais telefônicos. SEMETRO, 2009quem mais cita →

Quem cita esta obra

nenhum artigo do acervo cita esta obra — ainda

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações