Tenoxicam, a piroxicam analogue, is an NSAID (Non-Steroid Antinflamatory Drug). It is used in the symptomatic management of musculoskeletal and joint disorders such as osteoarthritis and rheumatoid arthritis, and also in the short-term management of soft-tissue injury. Its quantitative determination in pharmaceutical formulations is important to guarantee the desired therapeutic effects. The objective of this research was to develop, validate and compare spectrophotometric and chromatographic methods in the quantitative determination of tenoxicam in tablet preparations. In this work, tablets containing 20.0 mg of tenoxicam from different origins were analyzed. The spectrophotometric method was validated using 0.1 mol/L NaOH as solvent and a signal at 368 nm was taken. The HPLC method was validated using Synergi Hydro-RP® C18 column (250x4.6 mm, 4 µm). The mobile phase was constituted of methanol-water (61:39 v/v) with pH adjusted to 2.5 with formic acid, at a flow rate of 1.0 mL/min. UV detection was made at 375 nm. All analyses were performed with a column temperature of 25 °C ± 1. The calibration curves were linear over a concentration range from 4.0-24.0 µg/mL with a correlation coefficient better than 0.9999. The detection limit (DL) and quantitation limit (QL) were 0.25 µg/mL and 0.90 µg/mL for UV method and 0.35 µg/mL and 1.20 µg/mL for HPLC method respectively. The intra-day and inter-day precision expressed as RSD were below 2% for both methods. The mean recovery of tenoxicam was found to be in the range of 98.5-101.25% for UV method and 99.01-101.93% for HPLC method. The UV and HPLC methods were found to be rapid, precise and accurate. Statistically there was no significant difference between proposed UV spectrophotometric and HPLC methods.
como citar · ABNT NBR 6023
SINGH, Anil Kumar et al. Comparative study on two rapid and sensitive methods for quantitative determination of tenoxicam in tablets. Revista Brasileira de Ciências Farmacêuticas, 2007. Disponível em: https://www.scielo.br/scielo.php?script=sci_arttext&pid=S1516-93322007000400015. Acesso em: 27 nov. 2026.
Referências
28 obras citadas
- 1M.E. ABDEL-HAMID. LC-MS analysis of selected sulfur-containing non-steroid anti-inflammatory agents: Applications to pharmaceutical products. J. Liq. Chromatogr. Relat. Technol., 2000quem mais cita →
- 2A.S. AMIN. Spectrophotometric determination of piroxicam and tenoxicam in pharmaceutical formulations using alizarin. J. Pharm. Biomed. Anal., 2002quem mais cita →
- 3AOAC INTERNATIONAL. Official Methods of Analysis. 1990quem mais cita →
- 4O. ATAY e F. DINÇOL. Quantitative determination of tenoxicam by infrared spectrophotometry. Anal. Lett., 1997quem mais cita →
- 5Z. ATKOPAR e M. TUNÇEL. The polarographic determination of tenoxicam in the pharmaceutical preparations. Anal. Lett., 1996quem mais cita →
- 6M.H. BARARY, M.H. ABDEL-HAY, S.M. SABRY e mais 1. Spectrofluorimetric determination of 2-aminopyridine as a potential impurity in piroxicam and tenoxicam within the pharmacopoeial limit. J. Pharm. Biomed. Anal., 2004quem mais cita →
- 7H. BARTSCH, A. EIPER, H. KOPELENT-FRANK e mais 1. Selective assays for quantitation of tenoxicam in presence of its photodegradation products. J. Liq. Chromatogr. Relat. Technol., 2002quem mais cita →
- 8G. CARLUCCI, P. MAZZEO e G. PALUMBO. Determination of tenoxicam in human plasma using solid-phase extraction and high-performance liquid chromatography with ultraviolet detection. J. Liq. Chromatogr. Relat. Technol., 1992quem mais cita →
- 9J.S. DIXON, J.R. LOWE e D.B. GALLOWAY. Rapid method for the determination of either piroxicam or tenoxicam in plasma using high-performance liquid chromatography. J. Chromatogr., 1984quem mais cita →
- 10A.F.M. EL WALILY, S.M. BLAIH, M.H. BARARY e mais 3. Simultaneous determination of tenoxicam and 2-aminopyridine using derivative spectrophotometry and high-performance liquid chromatography. J. Pharm. Biomed. Anal., 1997quem mais cita →
- 11M.A. EL-RIES. Spectrophotometric determination of piroxicam and tenoxicam in pharmaceutical preparations using uranyl acetate as a chromogenic agent. Anal. Lett., 1998quem mais cita →
- 12M.A. EL-RIES, G. MOHAMED, S. KHALIL e mais 1. Spectrophotometric and potentiometric determination of piroxicam and tenoxicam in pharmaceutical preparations. Chem. Pharm. Bull., 2003quem mais cita →
- 13M.S. GARCIA, C. SANCHEZ-PEDREÑO, M. ALBERO e mais 1. Flow-injection spectrophotometric methods for the determination of tenoxicam. J. Pharm. Biomed. Anal., 1999quem mais cita →
- 14Y.J. HYE, W.L. HYE, H.K. YOUNG e mais 2. Simultaneous determination of piroxicam, meloxicam and tenoxicam in human plasma by liquid chromatography with tandem mass spectrometry. J. Chromatogr., B: Anal. Technol. Biomed. Life Sci., 2005quem mais cita →
- 15INTERNATIONAL CONFERENCE ON HARMONIZATION. Text on validation of analytical procedure: methodology: Q2(R1). 2005quem mais cita →
- 16J. JOSEPH-CHARLES e M. J. BERTUCAT. Simultaneous high performance liquid chromatographic analysis of non- steroidal anti-inflammatory oxicams in pharmaceutical preparations. J. Liq. Chromatogr. Relat. Technol., 1999quem mais cita →
- 17J.L. MASON e G.J. HOBBS. Simple method for the analysis of tenoxicam in human plasma using high-performance liquid chromatography. J. Chromatogr., B: Anal. Technol. Biomed. Life Sci., 1995quem mais cita →
- 18A.R. MCKINNEY, C.J. SUANN e A.M. STENHOUSE. The detection of piroxicam, tenoxicam and their metabolites in equine urine by electrospray ionisation ion trap mass spectrometry. Rapid Commun. Mass Spectrom., 2004quem mais cita →
- 19M.I. MUNERA-JARAMILLO e S. BOTERO-GARCES. Determination of tenoxicam in plasma by high-performance liquid chromatography. J. Chromatogr., B: Anal. Technol. Biomed. Life Sci., 1993quem mais cita →
- 20K. NIKOLIC, M. BOGAVAC e L. ARSENIJEVIC. Coulometric determination of some antiinflammatory compounds. Farmaco, 1993quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda