Brazilian Archives of Biology and Technology2010
Biocompatibility, osteointegration, osteoconduction, and biodegradation of a hydroxyapatite-polyhydroxybutyrate composite
Emily Correna Carlo Reis, Andréa Pacheco Batista Borges, Cláudio César Fonseca, Mastoby Miguel Martinez Martinez, Renato Barros Eleotério, Gláucia Oliveira Morato e Paulo Miranda Oliveira
em inglês
resumo
In this work, biocompatibility, osteointegration, osteoconductivity, and biodegradation of a hydroxyapatite polyhydroxybutyrate new composite were evaluated. The composite was implanted in rabbits' bone defects and clinical, radiographic, histological, and histomorphometric data of these animals were compared with those of unfilled defects on the days 8th, 45th, and 90th after surgery. No significant differences existed between the groups for the evaluated clinical parameters. Radiographs showed bone-composite direct contact. Bone formed within the defect, interface and inside the composite. Significant differences were found between the bone and connective tissues percentage within the defect at all dates and at the interface on the 45th day, bone tissue prevailing. Composite's biodegradation signs were evident: giant cells on the surface of composite fragments separated from the original block in the absence of inflammatory infiltrate. These data supported that such composite was biocompatible, biodegradable, osteoconductive and integrate to bone.
como citar · ABNT NBR 6023
REIS, Emily Correna Carlo et al. Biocompatibility, osteointegration, osteoconduction, and biodegradation of a hydroxyapatite-polyhydroxybutyrate composite. Brazilian Archives of Biology and Technology, 2010. Disponível em: https://www.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132010000400010. Acesso em: 28 nov. 2026.
Referências
23 obras citadas · 2 no acervo
- 1F.C Boer, B.W Wippermann, F.J Blokhuis e mais 3. Healing of segmental bone defects with granular porous hydroxyapatite augmented with recombinant human osteogenic protein-1 or autologous bone marrow. J Orthop Res, 2003quem mais cita →
- 2N.R Boeree, J Dove, J.J Cooper e mais 2. Development of a degradable composite for orthopaedic use: mechanical evaluation of an hydroxyapatite-polyhydroxybutyrate composite material. Biomaterials, 1993quem mais cita →
- 3A.P.B Borges, C.M.F Rezende, M.F.B Ribeiro e mais 2. Hidroxiapatita sintética como substituto ósseo em defeito experimental provocado no proximal da tíbia de cão: aspectos à microscopia de transmissão. Arquivo Brasileiro de Medicina Veterinária e Zootecnia, 2000quem mais cita →
- 4J.E Davies e N Baldan. Scan. electron microscopy of the bone-bioactive implant interface. J Biomed Mater Res, 1997quem mais cita →
- 5J.L de Godoy, E.K Otta, R.A Miyazaki e mais 2. Central venous access through external jugular vein in children submitted do bone marrow transplantation. Braz Arch Biol Tech, 2005quem mais cita →
- 6C Doyle, E.T Tanner e W Bonflield. In vitro and in vivo evaluation of polyhydroxybutyrate and of polyhydroxybutyrate reinforced with hydroxyapatite. Biomaterials, 1991quem mais cita →
- 7S Fujibayashi, N Masashi, A.M Kim e mais 2. A comparative study between in vivo bone ingrowth and in vitro apatite formation on Na2O-CaO-Si2 glasses. Biomaterials, 2003quem mais cita →
- 8D.J Griffon. Fracture healing. AO Principles of Fracture Management in the dog and cat, 2005
- 9Y Ito, H Hasuda, A. M Kamitakahara e mais 4. A composite of Hydroxyapatite with electrospun biodegradable nanofibers as a tissue engineering material. J Biosci Bioeng, 2005quem mais cita →
- 10J.C Knowles, G.W Hastings, H Ohta e mais 2. Development of degradable composite for orthopaedic use: in vivo biomechanical of two bioactive degradable composites based on the polyhydroxybutyrate polymer. Biomaterials, 1992quem mais cita →
- 11T Kokubo, H.M Kim e M Kawashita. Novel bioactive materials with different mechanical properties. Biomaterials, 2003quem mais cita →
- 12K.A Lacerda, F.S Lameiras e V.V Silva. Quantification of iodine in porous hydroxyapatite matrices for application as radioactive sources in brachytherapy. Braz Arch Biol Tech, 2007no acervo →
- 13W Linhart, W Lehmann, M Siedler e mais 6. Composites of amorphous calcium phosphate and poly(hydroxybutyrate) and poly(hydroxybutyrateco-hydroxyvalerate) for bone substitution: assessment of the biocompatibility. J Biomed Mater Res, 2001quem mais cita →
- 14Z.B Luklinska e W Bonfield. Morphology and ultrastructure of the interface between hydroxyalatite-polyhydroxybutyrate composite implant and bone. J Mater Sci-Mater M, 1997quem mais cita →
- 15S.R Macneill, C.M Cobb, J.W Rapley e mais 2. In vivo comparison of synthetic osseous graft materials: A preliminary study. J Clin Periodontol, 1999quem mais cita →
- 16E.S Miranda, F.T.S Cardoso, J.F.F Medeiros e mais 4. Estudo experimental comparativo no uso de enxerto ósseo orgânico e inorgânico no reparo de fraturas cirúrgicas em rádio de coelhos. Acta Ortopédica Brasileira, 2005no acervo →
- 17P.M Oliveira. Desenvolvimento e caracterização de compósitos de matriz polimérica de PHB reforçados com HAP-91. 2005quem mais cita →
- 18E Rumpel, E Wolf, E Kauschke e mais 4. The biodegradation of hydroxyapatite bone graft substitutes in vivo. Folia Morphology, 2006quem mais cita →
- 19M.J.C Sá, C.M.F Rezende, V.A Silva junior e mais 3. In vivo behavior of zirconia-hydroxyapatite (ZH) ceramic implants in dogs: a clinical, radiographic, and histological study. J Biomater Appl, 2007quem mais cita →
- 20I. E Saba-chujfi, S.A.S Pereira e M.E.C Saba. Opções cirúrgicas na terapia da bolsa periodontal. Periodontia, Cirurgia, Cirurgia para implantes, 2002quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda