Brazilian Archives of Biology and Technology2005

Technetium-99m ceftizoxime kit preparation

Simone Odília Fernandes Diniz, Cristiano Ferrari Siqueira, David Lee Nelson, Josep Martin-Comin e Valbert Nascimento Cardoso

em inglês

cita 18 obras, 1 no acervo

resumo

The aim of this work was to prepare a kit of 99mTc-ceftizoxime (99mTc-CFT), with stability and biological activity preserved, able to identify a septic focus (E. coli) in the experimental infection model in rats. The preparation of the CFT kit involved the use of lyophilized solutions containing the antibiotic ceftizoxime and the sodium dithionite reducing agent (6.0 mg/mL). After lyophilization, the kit was reconstituted with 1.0 mL of sodium 99mTc-pertechnetate solution (Na99mTcO4-) with an activity of 370 MBq. The solution was boiled for 10 min and filtered through a cellulose ester filter. The labeling efficiency was on the order of 92%, remaining stable for six hours and the kit remained stable for two months. The biological activity of the 99mTc-CFT was evaluated by diffusion in agar impregnated with E.coli and S. aureus. Seven Wistar rats, weighing from 200 to 250 g, were used for the development of the septic focus. After 24 hours from the induction of the infectious site (E.coli), the animals were anesthetized and 0.1 mL of 99mTc-CFT (37 MBq) was injected into the tail veins of the animals. The images were obtained with a gamma camera one, two and six hours after injection and the regions of interest (ROIs) were calculated. The diameters of the inhibition halos for 99mTc-CFT were 27.16 ± 0.23 and 27.17 ± 0.20 for S.aureus and E.coli, respectively, while those for the unlabeled CFT were 30.4 ± 0.33 and 29.43 ± 0.26, respectively. The results for the biodistribution of 99mTc-CFT in infected animals furnished a ratio of 1.97 ± 0.31, 2.10 ± 0.42 and 2.01 ± 0.42 for cpm-target/cpm-no target for the one, two and six-hour periods, respectively. The images showed a clear uptake of labeled antibiotic (99mTc-CFT) by the infectious site during the experiment. The results attest to the viability of producing a kit with 99m technetium-labeled ceftizoxime for the investigation of infectious processes.

como citar · ABNT NBR 6023

DINIZ, Simone Odília Fernandes et al. Technetium-99m ceftizoxime kit preparation. Brazilian Archives of Biology and Technology, 2005. Disponível em: https://www.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132005000700014. Acesso em: 29 nov. 2026.

Referências

18 obras citadas · 1 no acervo

  1. 1V.G. Barreto, F. Iglesias, M. Roca e mais 2. Marcaje de ceftizoxime com 99mTc. Rev. Esp. Med. Nuclear, 2000quem mais cita →
  2. 2W. Becker. The contribution of nuclear medicine to the patient with infection. Eur. J. Nucl. Med., 1995quem mais cita →
  3. 3G. Brasileiro Filho. Bogliolo Patologia. 2000
  4. 4K.E. Britton, S. Vinjamuri, A.V. Hall e mais 4. Clinical evaluation of technetium-99m infecton for the localization of bacterial infection. Eur. J. nucl. Med., 1997quem mais cita →
  5. 5J.R. Buscombe, R.F Miller e D Lui. Combined Gallium-67-citrate and 99mTc-human immunoglobulin imaging in human immunodeficiency virus-positive patients with fever of unknown origin. Nucl. Med. Commun, 1991quem mais cita →
  6. 6V.N Cardoso, P. Plaza, M. Roca e mais 2. Assessment of inflammatory bowel disease with two different 99mTc-Leucocytes labelling methods. Nucl. Med. Commun., 2002quem mais cita →
  7. 7A.V. Hall. Evaluation of the efficacy of 99mTc-Infecton, a novel agent for detecting sites of infection. J. Clin. Pathol., 1998quem mais cita →
  8. 8M.J. Larikka, A.K. Ahonen, O. Niemelä e mais 5. Comparison of 99mTc-ciprofloxacin, 99mTc white blood cell and three-phase bone imaging in the diagnosis of hip prosthesis infections: improved diagnostic accuracy with extended imaging time. Nucl. Med. Commun., 2002quem mais cita →
  9. 9M.J. Larikka, A.K. Ahonen, O. Niemelä e mais 5. 99mTc-ciprofloxacin (Infecton) imaging in the diagnosis of knee prosthesis infections. Nucl Med. Commum., 2002quem mais cita →
  10. 10J. Martin-Comin, V.N. Cardoso e P. Plaza. Hank’s balanced salt solution: an alternative resuspension medium to label autologous leukocytes. Experience in inflammatory bowel disease. Braz. arch. biol. technol., 2002no acervo →
  11. 11J.G. McAfee, G. Gagne, G. Subramanian e mais 1. The localization of indium-111-leucocytes, gallium-67, polyclonal IgG and other radioactive agents in acute focal inflammatory lesions. J. Nucl. Med., 1991quem mais cita →
  12. 12R.N. Mitchell e R.S. Cotran. Acute and chronic inflammation. Robbins basic pathology, 2003quem mais cita →
  13. 13C.B. Sampson. Complications and difficulties in radiolabelling blood cells: A review. Nucl. Med. Commun., 1996quem mais cita →
  14. 14K. Sonmezoglu, M. Sonmezoglu, M. Halac e mais 7. Usefulness of 99mTc-Ciprofloxacin (infecton) scan in diagnosis of chronic orthopedic infections: Comparative study with 99mTc-HMPAO leukocyte scintigraphy. J. Nucl. Med., 2001quem mais cita →
  15. 15W. Tavares. Manual de antibióticos e quimioterápicos antiinfecciosos. 2002quem mais cita →
  16. 16R. Weiner. The role of transferring and other receptors in the mechanism of Ga67 localization. Int. J. Rad. Appl. Instrum. B., 1990quem mais cita →
  17. 17S.H. Vinjamuri, A.V. Hall e K.K. Solanki. Comparison of 99mTc-Infecton imaging with radiolabelled white-cell imaging in the evaluation of bacterial infection. Lancet, 1996quem mais cita →
  18. 18Z. Yapar, M. Kibar, A.F. Yapar e mais 3. The efficacy of 99m technetium ciprofloxacin (Infecton) imaging in suspected orthopaedic infection: a comparison with sequential bone/gallium imaging. Eur. J. Nucl. Med., 2001quem mais cita →

Quem cita esta obra

nenhum artigo do acervo cita esta obra — ainda