Sao Paulo Medical Journal2022

Performance and reference intervals of thrombin generation test: results from the Brazilian longitudinal study of adult health (ELSA-Brasil). A cross-sectional study

Danyelle Romana Alves Rios, Sandhi Maria Barreto, Letícia Gonçalves Resende Ferreira, Thaís Resende Batista, Ana Paula Ferreira Silva, Wander Valadares de Oliveira Júnior, Chams Bicalho Maluf, Maria das Graças Carvalho e Roberta Carvalho Figueiredo

em inglês

citado por 1 artigocita 49 obras, 2 no acervo

resumo

ABSTRACT BACKGROUND: The thrombin generation test (TGT) has shown promise for investigation of hemorrhagic and thrombotic diseases. However, despite its potential, it still needs standardization. Moreover, few studies have established reference values for TGT parameters. In Brazil, these values have not yet been established. OBJECTIVE: To determine TGT performance and reference intervals for TGT parameters in healthy individuals. DESIGN AND SETTING: Cross-sectional study conducted among participants in the Brazilian Longitudinal Study of Adult Health (Estudo Longitudinal de Saúde do Adulto, ELSA-Brasil). METHODS: The reference sample consisted of 620 healthy individuals. The calibrated automated thrombogram (CAT) method, under low and high tissue factor (TF) conditions, was used to assess thrombin generation. Test performance was analyzed using intra and interassay coefficients of variation (CV) and reference intervals were calculated using the nonparametric method proposed by the International Federation of Clinical Chemistry and the Clinical and Laboratory Standards Institute. RESULTS: The intraassay CV ranged from 1.4% to 2.2% and the interassay CV, 6.8% to 14.7%. The reference intervals for TGT parameters under low and high TF conditions were, respectively: lagtime: 3.0-10.3 and 1.4-3.7 min; endogenous thrombin potential (ETP): 1134.6-2517.9 and 1413.6-2658.0 nM.min; normalized ETP: 0.6-1.3 and 0.7-1.4; peak: 103.2-397.7 and 256.4-479.0 nM; normalized peak: 0.3-1.3 and 0.7-1.2; and time-to-peak: 5.6-16.0 and 3.4-6.7 min. These parameters were categorized relative to sex. Conclusion: TGT performance was adequate and the proposed reference intervals were similar to those of other studies. Our findings may be useful for consolidating the TGT, through contributing to its standardization and validation.

como citar · ABNT NBR 6023

RIOS, Danyelle Romana Alves et al. Performance and reference intervals of thrombin generation test: results from the Brazilian longitudinal study of adult health (ELSA-Brasil). A cross-sectional study. Sao Paulo Medical Journal, 2022. DOI: 10.1590/1516-3180.2021.0425.R1.07102021.

Referências

49 obras citadas · 2 no acervo

  1. 1T Baglin. The measurement and application of thrombin generation. Br J Haematol., 2005quem mais cita →
  2. 2HC Hemker, P Giesen e R Al Dieri. Calibrated automated thrombin generation measurement in clotting plasma. Pathophysiol Haemost Thromb., 2003quem mais cita →
  3. 3A Tripodi. Thrombin generation assay and its application in the clinical laboratory. Clin Chem., 2016quem mais cita →
  4. 4S Bloemen, H Kelchtermans e HC Hemker. Thrombin generation in low plasma volumes. Thromb J., 2018quem mais cita →
  5. 5E Castoldi e J Rosing. Thrombin generation tests. Thromb Res., 2011quem mais cita →
  6. 6C Lecut, P Peters, PB Massion e mais 1. Quelle place pour le test de génération de thrombine au sein du laboratoire de biologie clinique? [Is there a place for thrombin generation assay in routine clinical laboratory?]. Ann Biol Clin (Paris)., 2015quem mais cita →
  7. 7E Berntorp e GL Salvagno. Standardization and clinical utility of thrombin-generation assays. Semin Thromb Hemost., 2008quem mais cita →
  8. 8J Wan, J Konings e Q Yan. A novel assay for studying the involvement of blood cells in whole blood thrombin generation. J Thromb Haemost., 2020quem mais cita →
  9. 9E Santagostino, ME Mancuso e A Tripodi. Severe hemophilia with mild bleeding phenotype: Molecular characterization and global coagulation profile. J Thromb Haemost., 2010quem mais cita →
  10. 10AE Bowyer, JJ Van Veen, AC Goodeve e mais 2. Specific and global coagulation assays in the diagnosis of discrepant mild hemophilia A. Haematologica., 2013quem mais cita →
  11. 11DE Schmidt, R Chaireti e M Bruzelius. Correlation of thromboelastography and thrombin generation assays in warfarin-treated patients. Thromb Res., 2019quem mais cita →
  12. 12MS Park, GM Spears e KR Bailey. Thrombin generation profiles as predictors of symptomatic venous thromboembolism after trauma. J Trauma Acute Care Surg., 2017quem mais cita →
  13. 13S Eichinger, G Hron, M Kollars e mais 1. Prediction of Recurrent Venous Thromboembolism by Endogenous Thrombin Potential and D-Dimer. Clin Chem., 2008quem mais cita →
  14. 14A Tripodi, C Legnani e V Chantarangkul. High thrombin generation measured in the presence of thrombomodulin is associated with an increased risk of recurrent venous thromboembolism. J Thromb Haemost., 2008quem mais cita →
  15. 15RCF Duarte, DRA Rios e SM Rezende. Standardization and evaluation of the performance of the thrombin generation test under hypo- and hypercoagulability conditions. Hematol Transfus Cell Ther., 2019no acervo →
  16. 16Y Dargaud, R Luddington e E Gray. Effect of standardization and normalization on imprecision of calibrated automated thrombography: An international multicentre study. Br J Haematol., 2007quem mais cita →
  17. 17Y Dargaud, R Luddington e E Gray. Standardisation of thrombin generation test - which reference plasma for TGT? An international multicentre study. Thromb Res., 2010quem mais cita →
  18. 18Y Dargaud, AS Wolberg e R Luddington. Evaluation of a standardized protocol for thrombin generation measurement using the calibrated automated thrombogram: An international multicentre study. Thromb Res., 2012quem mais cita →
  19. 19Y Dargaud, AS Wolberg e E Gray. Proposal for standardized preanalytical and analytical conditions for measuring thrombin generation in hemophilia: communication from the SSC of the ISTH. J Thromb Haemost., 2017quem mais cita →
  20. 20S Bloemen, D Huskens e J Konings. Interindividual Variability and Normal Ranges of Whole Blood and Plasma Thrombin Generation. J Appl Lab Med An AACC Publ., 2017quem mais cita →
1–20 de 49 obras citadas

Quem cita esta obra

1 artigo do acervo

quem fala desta obra

6 pessoas

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações