Sao Paulo Medical Journal2007

Does the use of paclitaxel or rapamycin-eluting stent decrease further need for coronary-artery bypass grafting when compared with bare-metal stent?

Hernani Pinto de Lemos Júnior e Álvaro Nagib Atallah

em inglês

citado por 2 artigoscita 32 obras

resumo

CONTEXT AND OBJECTIVE: The safety and efficacy of drug-eluting stents reduce the need for surgical revascularization. The objective of the present study was to investigate whether paclitaxel or rapamycin-eluting stent are effective in avoiding the need for coronary-artery bypass grafting. METHODS: This was a systematic review of the literature using the methodology of the Cochrane Collaboration. The type of study considered was controlled randomized trials; the type of intervention was drug-eluting or bare-metal stents; and the main outcome investigated was coronary-artery bypass grafting. RESULTS: The ten studies included in this systematic review did not show any statistically significant difference between the drug-eluting stents and the bare-metal stents with regard to the outcome of coronary-artery bypass grafting (confidence interval: 0.31 to 1.42). CONCLUSION: The surgical revascularization rate was not reduced by the use of drug-eluting stents.

como citar · ABNT NBR 6023

LEMOS JÚNIOR, Hernani Pinto de; ATALLAH, Álvaro Nagib. Does the use of paclitaxel or rapamycin-eluting stent decrease further need for coronary-artery bypass grafting when compared with bare-metal stent? Sao Paulo Medical Journal, 2007. DOI: 10.1590/S1516-31802007000400010.

Referências

32 obras citadas

  1. 1A Betriu, M Masotti e A Serra. Randomized comparison of coronary stent implantation and balloon angioplasty in the treatment of de novo coronary artery lesions (START): a fouryear follow-up. J Am Coll Cardiol., 1999quem mais cita →
  2. 2DL Fischman, MB Leon e DS Baim. A randomized comparison of coronary-stent placement and balloon angioplasty in the treatment of coronary artery disease: Stent Restenosis Study Investigators. N Engl J Med., 1994quem mais cita →
  3. 3PW Serruys, P de Jaegere e F Kiemeneij. A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease: Benestent Study Group. N Engl J Med., 1994quem mais cita →
  4. 4MN Babapulle e MJ Eisenberg. Coated stents for the prevention of restenosis: Part I. Circulation, 2002quem mais cita →
  5. 5JPT Higgins e S Green. Cochrane Handbook for Systematic Reviews of Interventions 4.2.6. The Cochrane Libray, issue 4, 2006quem mais cita →
  6. 6AR Jadad, RA Moore e D Carroll. Assessing the quality of reports of randomized clinical trials: is blinding necessary?. Control Clin Trials, 1996quem mais cita →
  7. 7E Grube, S Silber e KE Hauptmann. TAXUS I: six- and twelve-month results from a randomized, double-blind trial on a slow-release paclitaxel-eluting stent for de novo coronary lesions. Circulation, 2003quem mais cita →
  8. 8A Colombo, J Drzewiecki e A Banning. Randomized study to assess the effectiveness of slow- and moderate-release polymer-based paclitaxel-eluting stents for coronary artery lesions. Circulation, 2003quem mais cita →
  9. 9GW Stone, SG Ellis e DA Cox. A polymer-based, paclitaxeleluting stent in patients with coronary artery disease. N Engl J Med., 2004quem mais cita →
  10. 10A Gershlick, I De Scheerder e B Chevalier. Inhibition of restenosis with a paclitaxel-eluting, polymer-free coronary stent: the European evaLUation of pacliTaxel Eluting Stent (ELUTES) trial. Circulation, 2004quem mais cita →
  11. 11SJ Park, WH Shim e DS Ho. A paclitaxel-eluting stent for the prevention of coronary restenosis. N Engl J Med., 2003quem mais cita →
  12. 12AJ Lansky, RA Costa e GS Mintz. Non-polymer-based paclitaxel-coated coronary stents for the treatment of patients with de novo coronary lesions: angiographic follow-up of the DELIVER clinical trial. Circulation, 2004quem mais cita →
  13. 13MC Morice, PW Serruys e JE Sousa. A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. N Engl J Med., 2002quem mais cita →
  14. 14JW Moses, MB Leon e JJ Popma. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med., 2003quem mais cita →
  15. 15E Schampaert, EA Cohen e M Schlüter. The Canadian study of the sirolimus-eluting stent in the treatment of patients with long de novo lesions in small native coronary arteries (CSIRIUS). J Am Coll Cardiol., 2004quem mais cita →
  16. 16J Schofer, M Schlüter e AH Gershlick. Sirolimus-eluting stents for treatment of patients with long atherosclerotic lesions in small coronary arteries: double-blind, randomised controlled trial (E-SIRIUS). Lancet, 2003quem mais cita →
  17. 17RevMan Analyses: Version 1.0 for Windows. Review Manager: Version 4.2 for Windows, 2003quem mais cita →
  18. 18K Toutouzas, A Colombo e C Stefanadis. Inflammation and restenosis after percutaneous coronary intervention. Eur Heart J., 2004quem mais cita →
  19. 19SH Hofma, DM Whelan, HM van Beusekom e mais 2. Increasing arterial wall injury after longterm implantation of two types of stent in a porcine coronary model. Eur Heart J., 1998quem mais cita →
  20. 20HD Danenberg, FG Welt, M Walker e mais 3. Systematic inflammation induced by lipopolysaccharide increases neointimal formation after balloon and stent injury in rabbits. Circulation, 2002quem mais cita →
1–20 de 32 obras citadas

Quem cita esta obra

2 artigos do acervo

ano a anomais citada em 2008 · 1 artigo
Mais citada em 2008, com 1 artigo.
  • 2008: citada em 1 artigo
  • 2011: citada em 1 artigo

quem fala desta obra

11 pessoas
ver as 11 pessoas e os artigos →

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações