Sao Paulo Medical Journal2004

Comparison between cardiac output values measured by thermodilution and partial carbon dioxide rebreathing in patients with acute lung injury

Jorge Luís dos Santos Valiatti e José Luiz Gomes do Amaral

em inglês

cita 40 obras

resumo

CONTEXT: Thermodilution, which is considered to be a standard technique for measuring the cardiac output in critically ill patients, is not free from relevant risks. There is a need to find alternative, noninvasive, automatic, simple and accurate methods for monitoring cardiac output at the bedside. OBJECTIVE: To compare cardiac output measurements by thermodilution and partial carbon dioxide rebreathing in patients with acute lung injury at two levels of severity (lung injury score, LIS: below 2.5, group A; and above 2.5, group B). TYPE OF STUDY: Comparative, prospective and controlled study. SETTING: Intensive Care Units of two university hospitals. METHODS: Cardiac output was measured by thermodilution and partial carbon dioxide rebreathing. Twenty patients with acute lung failure (PaO2/FiO2 < 300) who were under mechanical ventilation and from whom 294 measurements were taken: 164 measurements in group A (n = 11) and 130 in group B (n = 9), ranging from 14 to 15 determinations per patient. RESULTS: There was a poor positive correlation between the methods studied for the patients from groups A (r = 0.52, p < 0.001) and B (r = 0.47, p < 0.001). The application of the Bland-Altman test made it possible to expose the lack of agreement between the methods (group A: -0.9 ± 2.71 l/min; 95% CI = -1.14 to -0.48; and group B: -1.75 ± 2.05 l/min; 95% CI = -2.11 to -1.4). The comparison of the results (Student t and Mann-Whitney tests) within each group and between the groups showed significant difference (p = 0.000, p < 0.05). DISCUSSION: Errors in estimating CaCO2 (arterial CO2 content) from ETCO2 (end-tidal CO2) and situations of hyperdynamic circulation associated with dead space and/or increased shunt possibly explain our results. CONCLUSION: Under the conditions of this study, the results obtained allow us to conclude that, in patients with acute lung injury, the cardiac output determined by partial rebreathing of CO2 differs from the measurements obtained by thermodilution. This difference becomes greater, the more critical the lung injury is.

como citar · ABNT NBR 6023

VALIATTI, Jorge Luís dos Santos; AMARAL, José Luiz Gomes do. Comparison between cardiac output values measured by thermodilution and partial carbon dioxide rebreathing in patients with acute lung injury. Sao Paulo Medical Journal, 2004. DOI: 10.1590/S1516-31802004000600002.

Referências

40 obras citadas

  1. 1W Ganz, R Donoso, HS Marcus e mais 2. A new technique for measurement of cardiac output by thermodilution in man. Am J Cardiol, 1971quem mais cita →
  2. 2MB Sorensen, NE Bille-Brahe e HC Engell. Cardiac output measurement by thermal dilution: reproducibility and comparison with the dye-dilution technique. Ann Surg, 1976quem mais cita →
  3. 3CW Stetz, RG Miller, GE Kelly e mais 1. Reliability of the thermodilution method in the determination of cardiac output in clinical practice. Am Rev Respir Dis, 1982quem mais cita →
  4. 4JP Carpenter, S Nair e I Staw. Cardiac output determination: thermodilution versus a new computerized Fick method. Crit Care Med, 1985quem mais cita →
  5. 5JS Steingrub, G Celoria, M Vickers-Lahti e mais 2. Therapeutic impact of pulmonary artery catheterization in a medical/surgical ICU. Chest, 1991quem mais cita →
  6. 6MJ Sise, P Hollingsworth, JE Brimm e mais 3. Complications of the flow-directed pulmonary artery catheter: A prospective analysis in 219 patients. Crit Care Med, 1981quem mais cita →
  7. 7LA Kelson. Complications associated with pulmonary artery catheterization. New Horiz, 1997quem mais cita →
  8. 8C Patel, V Laboy, B Venus e mais 2. Acute complications of pulmonary artery catheter insertion in critically ill patients. Crit Care Med, 1986quem mais cita →
  9. 9AF Jr Connors, T Speroff e NV Dawson. The effectiveness of right heart catheterization in the initial care of critically ill patients: SUPPORT Investigators. JAMA, 1996quem mais cita →
  10. 10DG Haryadi, JA Orr, K Kuck e mais 2. Evaluation of a partial CO2 rebreathing Fick technique for measurement of cardiac output. Anesthesiology, 1998quem mais cita →
  11. 11KB Johnson, JA Orr, S McJames e mais 2. Influence of pulmonary edema on noninvasive measurements of cardiac output using partial CO2 rebreathing in a canine model. Anesthesiology, 1998quem mais cita →
  12. 12L Guzzi, MB Jaffe e JA Orr. Clinical evaluation of a new noninvasive method of cardiac output measurement: preliminary results in CABG patients. Anesthesiology, 1998quem mais cita →
  13. 13K Kück, DG Haryadi, JA Orr e mais 1. Evaluation of partial rebreathing cardiac output measurement during surgery. Anesthesiology, 1998quem mais cita →
  14. 14RC Watt, RG Loeb e JA Orr. Comparison of a new non-invasive cardiac output technique with invasive bolus and continuous thermodilution. Anesthesiology, 1998quem mais cita →
  15. 15M Botero, P Hess, D Kirby e mais 3. Cardiac output measurement during off pump coronary artery bypass grafting (OPCABG): comparison of four methods. Anesth Analg, 2000quem mais cita →
  16. 16JC Binder e WG Parkin. Non-invasive cardiac output determination: comparison of a new partial-rebreathing technique with thermodilution. Anaesth Intensive Care, 2001quem mais cita →
  17. 17AS Crespo, A Albuquerque, LA Campos e mais 1. Can NICO® be used in the intensive care unit on patients with mixed ventilation patterns and low cardiac output. Anesthesiology, 2001quem mais cita →
  18. 18S Tsujimoto, Y Arimura, N Kuroda e mais 2. Introduction and clinical evaluation of a new non-invasive cardiac output monitor (NICO) based on Fick partial CO2 rebreathing method. Masui, 2001quem mais cita →
  19. 19PV van Heerden, S Baker, SI Lim e mais 2. Clinical evaluation of the non-invasive cardiac output (NICO) monitor in the intensive care unit. Anaesth Intensive Care, 2000quem mais cita →
  20. 20H Odenstedt, O Stenqvist e S Lundin. Clinical evaluation of a partial CO2 rebreathing technique for cardiac output monitoring in critically ill patients. Acta Anaesthesiol Scand., 2002quem mais cita →
1–20 de 40 obras citadas

Quem cita esta obra

nenhum artigo do acervo cita esta obra — ainda

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações