Sao Paulo Medical Journal2002

Thyroid uptake and scintigraphy using 99mTc pertechnetate: standardization in normal individuals

Celso Darío Ramos, Denise Engelbrecht Zantut Wittmann, Elba Cristina Sá de Camargo Etchebehere, Marcos Antonio Tambascia, Cleide Aparecida Moreira Silva e Edwaldo Eduardo Camargo

em inglês

cita 17 obras

resumo

CONTEXT: Thyroid uptake and scintigraphy using 99mTc-pertechnetate has proven to be more advantageous than with 131I-iodide, since the images have better quality, the procedure is faster and the patient is submitted to a lower radiation dose. OBJECTIVE: The purpose of this study was to standardize a simple and fast methodology for performing thyroid uptake and scintigraphy and to determine the normal values for 99mTc- pertechnetate uptake. TYPE OF STUDY: Prospective, non-randomized. SETTING: Division of Nuclear Medicine, Department of Radiology, School of Medical Sciences, Campinas State University. PARTICIPANTS: The study consisted of 47 normal individuals, 30 women and 17 men, with ages ranging from 19 to 61 years (mean of 33 years). PROCEDURES: The laboratory assessment of thyroid function consisted of serum dosages of ultra-sensitive thyroxin and thyrotrophin. Twenty minutes after an intravenous injection of 10 mCi (370 MBq) of 99mTc-pertechnetate, the images were obtained on a computerized scintillation camera equipped with a low-energy high-resolution parallel hole collimator. RESULTS: All the individuals were euthyroid both on clinical and laboratory evaluation. The baseline thyroid 99mTc-pertechnetate uptake ranged from 0.4 to 1.7%. The uptake values obtained in these normal individuals showed that 95% presented a thyroid uptake that ranged from 0.4 to 1.5% of the injected dose. CONCLUSION: The assessment of thyroid structure and function using 99mTc-pertechnetate is a simple, fast and efficient method, which could easily become a part of the routine studies in nuclear medicine laboratories.

como citar · ABNT NBR 6023

RAMOS, Celso Darío et al. Thyroid uptake and scintigraphy using 99mTc pertechnetate: standardization in normal individuals. Sao Paulo Medical Journal, 2002. DOI: 10.1590/S1516-31802002000200004.

Referências

17 obras citadas

  1. 1EM Chapman. History of the discovery and early use of radioactive iodine. JAMA, 1983quem mais cita →
  2. 2RR Cavalieri e IR McDougall. "In vivo" isotopic tests and imaging. Werner & Ingbar: The thyroid, 1996quem mais cita →
  3. 3D Becker, ND Charkes e H Dworkin. Procedure guideline for thyroid scintigraphy. J Nucl Med, 1996quem mais cita →
  4. 4P Paras, DR Hamilton, C Evans e mais 2. Iodine-123 assay using a radionuclide calibrator. Int J Nucl Med Biol, 1983quem mais cita →
  5. 5HA Ziessman, FH Fahey e JM Gochoco. Impact of radiocontaminants in commercially available iodine-123: dosimetric evaluation. J Nucl Med, 1986quem mais cita →
  6. 6G Burke, A Halko, GE Silverstein e mais 1. Comparative thyroid uptake studies with 131I and 99mTcO4. J Clin Endocrinol Metab, 1972quem mais cita →
  7. 7CD Ramos, DE Zantut Wittmann, MA Tambascia e mais 3. Thyroid suppression test with L-thyroxine and [99mTc] pertechnetate. Clin Endocrinol, 2000quem mais cita →
  8. 8HP Higgins, D Ball e S Eastham. 20-Min 99mTc thyroid uptake: a simplified method using the gamma camera. J Nucl Med, 1973quem mais cita →
  9. 9G Andros, PV Harper, KA Lathrop e mais 1. Pertechnetate-99m localization in man with applications to thyroid scanning and the study of thyroid physiology. J Clin Endocrinol Metab, 1965quem mais cita →
  10. 10JJ Smith, BY Croft, VA Brookeman e mais 1. Estimation of 24-hour thyroid uptake of I-131 sodium iodide using a 5-minute uptake of technetium-99m pertechnetate. Clin Nucl Med, 1990quem mais cita →
  11. 11DB Sodee. The study of thyroid physiology utilizing intravenous sodium pertechnetate. J Nucl Med, 1966quem mais cita →
  12. 12MN Maisey, TK Natarajan, PJ Hurley e mais 1. Validation of a rapid computerized method of measuring 99mTc pertechnetate uptake for routine assessment of thyroid structure and function. J Clin Endocrinol Metab, 1973quem mais cita →
  13. 13PB Schneider. Simple, rapid thyroid function testing with 99mTc-pertechnetate thyroid uptake ratio and neck/thigh ratio. Am J Roentgenol, 1979quem mais cita →
  14. 14JB Selby, MG Buse, NS Gooneratne e mais 1. The Anger camera and the pertechnetate ion in the routine evaluation of thyroid uptake and imaging. Clin Nucl Med, 1979quem mais cita →
  15. 15JC Harbert. The thyroid. Nuclear medicine: diagnosis and therapy, 1996
  16. 16PJ Hurley, MN Maisey, TK Natarajan e mais 1. A computerized system for rapid evaluation of thyroid function. J Clin Endocrinol Metab, 1972quem mais cita →
  17. 17MS Sucupira, EE Camargo, EL Nickoloff e mais 2. The role of 99mTc pertechnetate uptake in the evaluation of thyroid function. Int J Nucl Med Biol, 1983quem mais cita →

Quem cita esta obra

nenhum artigo do acervo cita esta obra — ainda

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações