Effect of Processing on Microstructure and Corrosion Mitigating Properties of Hydrotalcite Coatings on AA 6061 Alloy
Stela Maria de Carvalho Fernandes, Olandir Vercino Correa, José Antonio Batista de Souza, Renato Altobelli Antunes, Nelson Batista de Lima e Lalgudi Venkataraman Ramanathan
em inglês
resumo
Pitting corrosion of the aluminium cladding of spent nuclear fuels stored in light water pools has been observed. To prevent this, coating of the Al cladding with hydrotalcite (HTC) was proposed. This paper presents the effect of chemical bath and processing parameters on microstructure and corrosion behavior of HTC coatings on alloy AA 6061 specimens. The HTC coating from the high temperature nitrate bath was homogeneous, thicker and consisted of well-defined intersecting platelets than that formed from the room temperature carbonate bath. Electrochemical polarization tests carried out with HTC coated AA 6061 specimens in 0.01 M NaCl revealed that specimens coated with HTC from the nitrate bath and further treated in a cerium salt solution were the most resistant to corrosion. Field tests in which un-coated and coated AA 6061 alloy coupons as well as full-size plates were exposed to the IEA-R1 reactor's spent fuel basin for duration of up to 14 months further corroborated the high corrosion resistance imparted by the high temperature HTC + Ce coating. The mechanism by which the HTC coating and cerium protect the Al alloy is discussed.
como citar · ABNT NBR 6023
FERNANDES, Stela Maria de Carvalho et al. Effect of Processing on Microstructure and Corrosion Mitigating Properties of Hydrotalcite Coatings on AA 6061 Alloy. Materials Research, 2015. DOI: 10.1590/1516-1439.015715.
Referências
17 obras citadas
- 1International Atomic Energy Agency - IAEA. Corrosion of research reactor aluminium clad spent fuel in water. 2003quem mais cita →
- 2LV Ramanathan, R Haddad, P Adelfang e mais 1. Corrosion of spent aluminium-clad research reactor fuel – Synergism in the role of storage basin water parameters. 2008quem mais cita →
- 3TG Harvey. Cerium based conversion coatings on aluminium alloys: a process review. Corrosion Engineering, Science and Technology, 2013quem mais cita →
- 4RG Buchheit, MD Bode e GE Stoner. Corrosion-resistant chromate-free talc coatings for aluminum. Corrosion, 1994quem mais cita →
- 5CA Drewien, MO Eatough, TR Tallant e mais 2. Lithium-aluminum-carbonate-hydroxide hydrate coatings on aluminium alloys: composition, structure, and processing bath chemistry. Journal of Materials Research, 1996quem mais cita →
- 6W Zhang e RG Buchheit. Hydrotalcite coating formation on Al-Cu-Mg alloys from oxidizing bath chemistries. Corrosion, 2002quem mais cita →
- 7BRW Hinton, DR Arnott e NE Ryan. Cerium conversion coatings for the corrosion protection of aluminum. Materials Forum, 1986quem mais cita →
- 8DR Arnott, NE Ryan, BRW Hinton e mais 2. Auger and XPS studies of cerium corrosion inhibition on 7075 aluminum alloy. Applications of Surface Science, 1985quem mais cita →
- 9M Dabalà, L Armelao, A Buchberger e mais 1. Cerium-based conversion layers on aluminum alloys. Applied Surface Science, 2001quem mais cita →
- 10AE Hughes, SG Hardin, KW Wittel e mais 1. Surface conversion of aluminum and aluminum alloys for corrosion protection. 2000quem mais cita →
- 11SMC Fernandes, OV Correa, JA Souza e mais 1. A coating to protect spent aluminium-clad research reactor fuel assemblies during extended wet storage. 2009quem mais cita →
- 12SMC Fernandes, OV Correa, JA Souza e mais 1. Lanthanide based conversion coatings for long term wet storage of aluminium-clad spent fuel. 2010quem mais cita →
- 13SMC Fernandes, OV Correa, JA Souza e mais 3. Conversion coatings to protect aluminium-clad spent fuel in wet storage. 2013quem mais cita →
- 14RG Buchheit, SB Mamidipally, P Schmutz e mais 1. Active corrosion protection in Ce-modified hydrotalcite conversion coatings. Corrosion, 2002quem mais cita →
- 15DR Arnott, BRW Hinton e NE Ryan. Cationic film-forming inhibitors for the corrosion protection of AA 7075 aluminum alloy in chloride solutions. Materials Performance, 1987quem mais cita →
- 16DR Arnott, BRW Hinton e NE Ryan. Cationic-film-forming inhibitors for the protection of the AA7075 aluminum alloy against corrosion in aqueous chloride solution. Corrosion, 1989quem mais cita →
- 17FH Scholes, C Soste, AE Hughes e mais 2. The role of hydrogen peroxide in the deposition of cerium based conversion coatings. Applied Surface Science, 2006quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda