ABSTRACT Constructed wetlands might be an alternative for communities away from urban centers and not served by a domestic wastewater treatment system. The purpose of this study was to provide instructions for the implementation of subsurface flow constructed wetland systems. To that end, we gathered information regarding the construction aspect, plants, and operational parameters used in systems which already operate in the country and the respective efficiency of these sets after previous treatment. The system in real scale proposed by Oliveira et al. (2005) was prominent among those that presented the highest efficiency. It was preceded by upflow anaerobic reactor built in brick, with macrophyte of the Typha genre, crushed stone at the entry and exit of the system, and sand in its intermediate portion. It required 1.04 m² surface area per inhabitant in humid temperate climate and hot summer, 1.71 m³ d-1 flow, and one-day hydraulic detention. The considerations presented here might help the construction of this kind of system, regarding dimensional and operational criteria.

como citar · ABNT NBR 6023

FADANELLI, Lis Eveline Athaydes et al. Considerations on design and implementation parameters of domestic wastewater treatment by subsurface flow constructed wetlands. Engenharia Sanitaria e Ambiental, 2019. DOI: 10.1590/S1413-41522019102334.

Referências

39 obras citadas · 6 no acervo

  1. 1R.A. ALMEIDA, D.P.S. PITALUGA e R.P.A. REIS. Tratamento de esgoto doméstico por zona de raízes precedida de tanque séptico. Revista Biociências, 2010quem mais cita →
  2. 2ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS (ABNT). NBR 7229: Projeto, construção e operação de sistemas de tanques sépticos. 1993quem mais cita →
  3. 3J.M. AZEVEDO NETTO. Sistema de esgotos sanitários. 1977quem mais cita →
  4. 4S. BIANCO, R.A. PITELLI e A.M.C.M. PITELLI. Estimativa da área foliar de Typha latifolia usando dimensões lineares do limbo foliar. Planta Daninha, 2003no acervo →
  5. 5BRASIL. Resolução CONAMA n. 357, de 17 de março de 2005. Dispõe sobre a classificação dos corpos de água e diretrizes ambientais para o seu enquadramento, bem como estabelece as condições e padrões de lançamento de efluentes, e dá outras providências. 2005quem mais cita →
  6. 6BRASIL. Resolução CONAMA n. 430, de 13 de maio de 2011. Dispõe sobre condições e padrões de lançamento de efluentes, complementa e altera a Resolução n. 357, de 17 de março de 2005, do Conselho Nacional do Meio Ambiente - CONAMA. 2011quem mais cita →
  7. 7V. CANO e M. GOMES. Avaliação da Eficiência Inicial de Wetlands Construídos no Pós-Tratamento de Reator UASB. 2011quem mais cita →
  8. 8C.A.L. CHERNICHARO, E. VAN HAANDEL e L.F. CYBIS. Pós-tratamento de efluentes de reatores anaeróbios. 2001quem mais cita →
  9. 9M.G.S. CORRÊA, J. VIÉGAS, J.B. SILVA e mais 3. Meiose e viabilidade polínica na família Araceae. Revista de Acta Botânica, 2005no acervo →
  10. 10J.F. COSTA, W.L.P. MARTINS, M. SEIDL e mais 1. Role of vegetation (Typha latifolia) on nutrient removal in a horizontal subsurface-flow constructed wetland treating UASB reactor-trickling filter effluent. Water Science and Technology, 2015quem mais cita →
  11. 11J.F. COSTA, A.C. PAOLI, M. SEIDL e mais 1. Performance and behaviour of planted and unplanted units of a horizontal subsurface flow constructed wetland system treating municipal effluent from a UASB reactor. Water Science and Technology, 2013quem mais cita →
  12. 12L.L. COSTA, B.S.O. CEBALLOS, C.M.B.S. MEIRA e mais 1. Eficiência de wetlands construídos com dez dias de detenção hidráulica na remoção de colífagos e bacteriófagos, Campina Grande, Brasil. Revista de Biologia e Ciências da Terra, 2003quem mais cita →
  13. 13F.L. DORNELAS, M.B. MACHADO e M. VON SPERLING. Performance evaluation of planted and unplanted subsurface-flow constructed wetlands for the post-treatment of UASB reactor effluents. Water Science and Technology, 2009quem mais cita →
  14. 14C.C.F. GANSKE e C.T. ZANOTELLI. Efficiency of the domestic westewater treatment system in root zones. 2008quem mais cita →
  15. 15L.C.O. LANA, D.C. MORAES, M. VON SPERLING e mais 4. Performance of a single stage vertical flow constructed wetland system treating raw domestic sewage in Brazil. Water Science and Technology, 2013quem mais cita →
  16. 16C. MAIER. Qualidade de águas superficiais e tratamento de águas residuárias por meio de zona de raízes em propriedades de agricultores familiares. 2007quem mais cita →
  17. 17V. MATAMOROS, Y. RODRÍGUEZ e J.M. BAYONA. Mitigation of emerging contaminants by full-scale horizontal flow constructed wetlands fed with secondary treated wastewater. Ecological Engineering, 2017quem mais cita →
  18. 18M.P. MATOS, M. VON SPERLING e A.T. MATOS. Clogging in horizontal subsurface flow constructed wetlands: influencing factors, research methods and remediation techniques. Reviews in Environmental Science and Biotechnology, 2018quem mais cita →
  19. 19R.C.M. MONTEIRO. Viabilidade técnica do emprego de sistemas tipo “wetlands” para tratamento de água cinza visando o reuso não potável. 2009quem mais cita →
  20. 20J.N. NAKAJIMA e J. SEMIR. Asteraceae do Parque Nacional da Serra da Canastra, Minas Gerais, Brasil. Revista Brasileira de Botânica, 2001no acervo →
1–20 de 39 obras citadas

Quem cita esta obra

nenhum artigo do acervo cita esta obra — ainda

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações