Revista Española de Enfermedades Digestivas2013
Comparative study of a responsive insertion technology (RIT) colonoscope versus a variable-stiffness colonoscope
César Prieto-de-Frías, Miguel Muñoz-Navas, Cristina Carretero, Juan Carrascosa, M.ª Teresa Betés, Susana de-la Riva, M.ª Teresa Herraiz e José Carlos Subtil
em inglês
resumo
Background and objectives: recently, Olympus developed a new prototype (XCF-Q180AY2L) with responsive insertion technology (RIT), which besides the still known variable stiffness technology, included a passive bending section and a new high force insertion tube. Our objective was to investigate whether the use of this prototype could ease colonoscope insertion, increasing the cecal intubation rate, and/or shortening the cecal intubation time. Material and methods: the study was designed as a prospective observational study in 305 consecutive patients from a colo-rectal cancer screening program. We compared colonoscopies performed with conventional colonoscopes (CFH180AL/CFQ160L) with those performed with the prototype XCF-Q180AY2L. End points were mean cecal and terminal ileal intubation times, cecum intubation rate, and need for specific maneuvers. All colonoscopies were performed under sedation with intravenous propofol. Finally, 288 patients were included. Results: no complications were observed. Complete cecal intubation rate was 100 % in both groups. The ileum could be reached in 98.95 % of cases. Mean time required to reach the cecum was shorter in the prototype endoscope group (4.31 min, SD 2.63 min) than in the conventional endoscope group (4.66 min, SD 2.52 min) (p < 0.05). Compared with the standard colonoscope group, we observed in the prototype group less subjective sensation of difficulty in the passage of the sigma (p < 0.01), fewer maneuvers when it proved necessary to straighten the scope (p < 0.01), and less frequent need to modify the stiffness of the endoscope (p < 0.05). Conclusion: we concluded that the prototype endoscope (XCF-Q180AY2L) facilitated colonoscope insertion, requiring slightly less time to reach the cecum than a standard colonoscope.
como citar · ABNT NBR 6023
PRIETO-DE-FRÍAS, César et al. Comparative study of a responsive insertion technology (RIT) colonoscope versus a variable-stiffness colonoscope. Revista Española de Enfermedades Digestivas, 2013. Disponível em: https://scielo.isciii.es/scielo.php?script=sci_arttext&pid=S1130-01082013000400005. Acesso em: 28 nov. 2026.
Referências
16 obras citadas
- 1DK Rex, JL Petrini, TH Baron e mais 3. Quality indicators for colonoscopy. Gastrointest Endosc, 2006quem mais cita →
- 2F Cardin, N Minicuci, A Andreotti e mais 3. Maximizing the general success of cecal intubation during propofol sedation in a multi-endoscopist academic centre. BMC Gastroenterol, 2010quem mais cita →
- 3MS Cappell e R Abboud. The impact of advances in instrumentation and techniques of colonoscopy from 1988 to 2008 on inpatient colonoscopy performance at a high volume endoscopy unit in the United States: Significantly shorter procedure time, higher completion rate, performance on sicker inpatients, and near disappearance of flexible sigmoidoscopy. Dig Dis Sci, 2010quem mais cita →
- 4G Hoff, M Bretthauer, G Huppertz-Hauss e mais 3. Evaluation of a novel colonoscope designed for easier passage through flexures: A randomized study. Endoscopy, 2005quem mais cita →
- 5G Hoff, V Moritz, M Bretthauer e mais 3. Colonoscope with a sub-distal hyper-flaccid segment for improved insertion at colonoscopy: A randomized study. Scand J Gastroenterol, 2011quem mais cita →
- 6Y Saito e H Kimura. Responsive insertion technology. Dig Endosc, 2011quem mais cita →
- 7EJ Lai, AH Calderwood, G Doros e mais 2. The Boston bowel preparation scale: A valid and reliable instrument for colonoscopy-oriented research. Gastrointest Endosc, 2009quem mais cita →
- 8JJ Hansen, BJ Ulmer e DK Rex. Technical performance of colonoscopy in patients sedated with nurse-administered propofol. Am J Gastroenterol, 2004quem mais cita →
- 9FW Leung. Methods of reducing discomfort during colonoscopy. Dig Dis Sci, 2008quem mais cita →
- 10DB Nelson, KR McQuaid, JH Bond e mais 3. Procedural success and complications of large-scale screening colonoscopy. Gastrointest Endosc, 2002quem mais cita →
- 11C Bernstein, M Thorn, K Monsees e mais 2. A prospective study of factors that determine cecal intubation time at colonoscopy. Gastrointest Endosc, 2005quem mais cita →
- 12WH Kim, YJ Cho, JY Park e mais 3. Factors affecting insertion time and patient discomfort during colonoscopy. Gastrointest Endosc, 2000quem mais cita →
- 13VP Deenadayalu, V Chadalawada e DK Rex. 170 degrees wide-angle colonoscope: Effect on efficiency and miss rates. Am J Gastroenterol, 2004quem mais cita →
- 14WR Kessler e DK Rex. Impact of bending section length on insertion and retroflexion properties of pediatric and adult colonoscopes. Am J Gastroenterol, 2005quem mais cita →
- 15JK Harris, F Froehlich, V Wietlisbach e mais 3. Factors associated with the technical performance of colonoscopy: An EPAGE Study. Dig Liver Dis, 2007quem mais cita →
- 16G Hoff, M Volker, M Bretthauer e mais 3. Gastronet survey on the use of one- or two-person technique for colonoscopy insertion. BMC Gastroenterol, 2011quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda