Revista da Associação Médica Brasileira2014

Angle-closure glaucoma: diagnosis

Jair Giampani Jr, Ricardo Simões e Wanderley Marques Bernardo

relato de caso · em inglês

cita 24 obras

resumo

The Guidelines Project, an initiative of the Brazilian Medical Association, aims to combine information from the medical field in order to standardize procedures to assist the reasoning and decision-making of doctors.The information provided through this project must be assessed and criticized by the physician responsible for the conduct that will be adopted, depending on the conditions and the clinical status of each patient.description of the evidence collection method:The literature review of scientific articles in this guideline was held in the databases Medline, Cochrane and SciELO.The search for evidence came from actual clinical scenarios and used keywords (MeSH terms) grouped in the following syntax: (glaucoma, angle-closure or glaucoma, closed angle or glaucomas, closed-angle or glaucoma, uncompensative or glaucomas, uncompensative or angle closure glaucoma or angle closure glaucomas or glaucomas, angle closure or glaucoma, narrow-angle) and (gonioscopy or tomography optical coherence or microscopy, acoustic or dark adaptation).The articles were selected after critical evaluation of the strength of scientific evidence, and publications of greatest strength were used for recommendation.The recommendations were drawn from group discussion.The entire guideline was reviewed by an independent group specializing in evidence-based clinical guidelines.deGree of recommendation and strenGth of evidence: A: Experimental or observational studies of higher consistency.B: Experimental or observational studies of lower consistency.C: Case reports (non-controlled studies).D: Opinions without critical evaluation, based on consensus, physiological studies, or animal models.Objective: To assess the main diagnostic methods used in angle-closure glaucoma in the light of the best available evidence.

como citar · ABNT NBR 6023

GIAMPANI JR, Jair; SIMÕES, Ricardo; BERNARDO, Wanderley Marques. Angle-closure glaucoma: diagnosis. Revista da Associação Médica Brasileira, 2014. DOI: 10.1590/1806-9282.60.03.004.

Referências

24 obras citadas

  1. 1PJ Foster. The epidemiology of primary angle closure and associated glaucomatous optic neuropathy. Semin Ophthalmol, 2002quem mais cita →
  2. 2JPC Vasconcelos, LM Sakata, MJL Silva e mais 1. 2º Consenso de Glaucoma Primário de Ângulo Fechado. 2012quem mais cita →
  3. 3CA Bruno e WL Alward. Gonioscopy in primary angle closure glaucoma. Semin Ophthalmol, 2002quem mais cita →
  4. 4DS Friedman e M He. Anterior chamber angle assessment techniques. Surv Ophthalmol, 2008quem mais cita →
  5. 5CJ Pavlin, K Harasiewicz, MD Sherar e mais 1. Clinical use of ultrasound biomicroscopy. Ophthalmology, 1991quem mais cita →
  6. 6X Kong, PJ Foster, Q Huang e mais 4. Appositional closure identified by ultrasound biomicroscopy in population-based primary angle-closure glaucoma suspects: The Liwan Eye Study. Invest Ophthalmol Vis Sci, 2011quem mais cita →
  7. 7D Wang, M Pekmezci, RP Basham e mais 3. Comparison of different modes in optical coherence tomography and ultrasound biomicroscopy in anterior chamber angle assessment. J Glaucoma, 2009quem mais cita →
  8. 8H Hirasawa, A Tomidokoro, S Kunimatsu e mais 3. Ultrasound biomicroscopy in narrow peripheral anterior chamber eyes with or without peripheral anterior synechiae. J Glaucoma, 2009quem mais cita →
  9. 9Y Barkana, SK Dorairaj, Y Gerber e mais 2. Agreement between gonioscopy and ultrasound biomicroscopy in detecting iridotrabecular apposition. Arch Ophthalmol, 2007quem mais cita →
  10. 10K Kashiwagi, T Tsumura e S Tsukahara. Comparison between newly developed scanning peripheral anterior chamber depth analyzer and conventional methods of evaluating anterior chamber configuration. J Glaucoma, 2006quem mais cita →
  11. 11PJ Foster, JG Devereux, PH Alsbirk e mais 3. Detection of gonioscopically occludable angles and primary angle closure glaucoma by estimation of limbal chamber depth in Asians: modified grading scheme. Br J Ophthalmol, 2000quem mais cita →
  12. 12DS Friedman e M He. Anterior chamber angle assessment techniques. Surv Ophthalmol, 2008quem mais cita →
  13. 13WB Khor, LM Sakata, DS Friedman e mais 3. Evaluation of scanning protocols for imaging the anterior chamber angle with anterior segment-optical coherence tomography. J Glaucoma, 2010quem mais cita →
  14. 14HT Wong, MC Lim, LM Sakata e mais 3. High-definition optical coherence tomography imaging of the iridocorneal angle of the eye. Arch Ophthalmol, 2009quem mais cita →
  15. 15F Aptel e P Denis. Optical coherence tomography quantitative analysis of iris volume changes after pharmacologic mydriasis. Ophthalmology, 2010quem mais cita →
  16. 16D Huang, EA Swanson, CP Lin e mais 3. Optical Coherence tomography. Science, 1991quem mais cita →
  17. 17JA Izatt, MR Hee, EA Swanson e mais 3. Micrometer-scale resolution imaging of the anterior eye in vivo with optical coherence tomography. Arch Ophthalmol, 1994quem mais cita →
  18. 18WP Nolan, JL See, PT Chew e mais 3. Detection of primary angle closure using anterior segment optical coherence tomography in Asian eyes. Ophthalmology, 2007quem mais cita →
  19. 19LM Sakata, R Lavanya, DS Friedman e mais 3. Comparison of gonioscopy and anterior segment ocular coherence tomography in detecting angle closure in different quadrants of the anterior chamber angle. Ophthalmology, 2008quem mais cita →
  20. 20AC Higgitt. The darkroom test. Br J Opthalmol, 1954
1–20 de 24 obras citadas

Quem cita esta obra

nenhum artigo do acervo cita esta obra — ainda

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações