Polímeros2016

Correlation between stabilizer consumption and degree of polymerization of thermally upgraded paper aged in insulating natural ester and insulating mineral oil

Larissa Mildemberger, Mario Carlos Andreoli, Guilherme Cunha da Silva, Heloisa Nunes da Motta, Joseane Valente Gulmine e Marilda Munaro

em inglês

cita 21 obras

resumo

Abstract Insulating paper holds significant importance in the insulation system of power transformers, and thus, its degradation is the subject of many studies. A successful evaluation of the degradation rate of such paper contributes to reducing downtime and avoiding equipment failure. In this work, samples of thermally upgraded paper were thermally aged in insulating natural ester (INE) and insulating mineral oil (IMO) and were evaluated by degree of polymerization (DP) and FTIR-ATR. It was possible to identify characteristic bands of dicyandiamide, an inhibitory compound of the thermal degradation of the paper, and to establish a correlation between the decrease in DP and the consumption of dicyandiamide during aging, which was observed to develop in three distinct steps for both IMO and INE.

como citar · ABNT NBR 6023

MILDEMBERGER, Larissa et al. Correlation between stabilizer consumption and degree of polymerization of thermally upgraded paper aged in insulating natural ester and insulating mineral oil. Polímeros, 2016. DOI: 10.1590/0104-1428.2003.

Referências

21 obras citadas

  1. 1I. Fofana, H. Bouslimi, C. Hemmatjou e mais 2. Relationship between static electrification of transformer oils with turbidity and spectrophotometry measurements. International Journal of Electrical Power & Energy Systems, 2014quem mais cita →
  2. 2T. A. Prevost. Thermally upgraded insulation in transformer. 2005quem mais cita →
  3. 3A. Ciuriuc, M. S. Vihacencu, L. M. Dumitran e mais 1. Comparative study on power transformers vegetable oil and mineral oil ageing. 2012quem mais cita →
  4. 4M. A. G. Martins. Furfuraldeído: um indicador prático da degradação térmica do papel kraft de transformadores. Ciência e Tecnologia dos Materiais, 2007quem mais cita →
  5. 5K. B. Liland, M. H. G. Ese, C. M Selsbak e mais 1. Ageing of oil impregnated thermally upgraded papers. 2011quem mais cita →
  6. 6J. Jalbert, R. Gilbert, P. Tétreault e mais 2. Identification of a chemical indicator of the rupture of 1,4-beta-glycosidic bonds of cellulose in an oil-impregnated insulating paper system. Cellulose, 2007quem mais cita →
  7. 7R. Gilbert, J. Jalbert, P. Tétreault e mais 2. Kinetics of the production of chain-end groups and methanol from the depolymerization of cellulose during the ageing of paper/oil systems. Part 1: standard wood kraft insulation. Cellulose, 2009quem mais cita →
  8. 8R. Gilbert, J. Jalbert, S. Duchesne e mais 3. Kinetics of the production of chain-end groups and methanol from the depolymerization of cellulose during the ageing of paper/oil systems. Part 2: thermally-upgraded insulating papers. Cellulose, 2010quem mais cita →
  9. 9R. Setnescu, L. V. Badicu, L. M. Dumitran e mais 2. Thermal lifetime of cellulose insulation material evaluated by an activation energy based method. Cellulose, 2014quem mais cita →
  10. 10M. A. Martins. Monitorização da degradação térmica do papel isolante usado em transformadores: papel “thermally upgraded” versus papel kraft. Ciência e Tecnologia dos Materiais, 2007quem mais cita →
  11. 11T. A. Prevost. Dielectric properties of natural esters and their influence on transformer insulation system design and performance: an update. 2009quem mais cita →
  12. 12C. P. McShane, K. J. Rapp, J. L. Corkran e mais 2. Aging of paper insulation in natural ester dielectric fluid. 2001quem mais cita →
  13. 13L. Yang, R. Liao, S. Caixin e mais 1. Influence of vegetable oil on the thermal aging of transformer paper and its mechanism. IEEE Transactions on Dielectrics and Electrical Insulation, 2011quem mais cita →
  14. 14G. K. Frimpong, T. V. Oommen e R. Asano. A survey of aging characteristics of cellulose insulation in natural ester and mineral oil. IEEE Electrical Insulation Magazine, 2011quem mais cita →
  15. 15Associação Brasileira de Normas Técnicas – ABNT. ABNT NBR IEC 60450: medição do grau de polimerização viscosimétrico médio de materiais celulósicos novos e envelhecidos para isolação elétrica. 2009quem mais cita →
  16. 16D. H. Shroff e A. W. Stannett. A review of paper aging in power transformers. IEE Proceedings. Part C. Generation, Transmission and Distribution, 1985quem mais cita →
  17. 17X. Yu, S. Tong, M. Ge e mais 4. Synthesis and characterization of multi-amino-functionalized cellulose for arsenic adsorption. Carbohydrate Polymers, 2013quem mais cita →
  18. 18J. M. Urreaga e M. U. Orden. Modification of cellulose with amino compounds: a fluorescence study. Carbohydrate Polymers, 2007quem mais cita →
  19. 19R. M. Morais, W. A. Mannheimer, M. Carballeira e mais 1. Furfural analysis for assessing degradation of thermally upgraded papers in transformer insulation. IEEE Transactions on Dielectrics and Electrical Insulation, 1999quem mais cita →
  20. 20L. Yang, R. Liao, C. Sun e mais 1. Study on the influence of natural ester on thermal ageing characteristics of oil-paper in power transformer. 2008quem mais cita →
1–20 de 21 obras citadas

Quem cita esta obra

nenhum artigo do acervo cita esta obra — ainda

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações