Revista Latino-Americana de Enfermagem2007

Low-temperature sterilization and new technologies

Vania Regina Goveia, Silma Maria Cunha Pinheiro e Kazuko Uchikawa Graziano

em inglês

citado por 2 artigoscita 11 obras

resumo

The new low-temperature sterilization technologies are presented as an alternative to the use of ethylene oxide. This review was performed in order to identify evidences of the antimicrobial activity, toxicity, adverse events and the applicability of these technologies. The research was carried through the electronic databases MEDLINE and LILACS up to 2005. The authors analyzed 10 articles in this survey. The studies about the efficacy of these sterilization methods constitute experimental and comparative research that showed the influence of the extension and diameter of the lumen, besides the presence of crystal salts. Thus, choosing the correct equipment is essential, as well as the assurance of the cleansing of the devices, which interfere with the effectiveness of the low-temperature sterilization. These technologies present limitations regarding the sterilization of graft bone and affect the materials properties.

como citar · ABNT NBR 6023

GOVEIA, Vania Regina; PINHEIRO, Silma Maria Cunha; GRAZIANO, Kazuko Uchikawa. Low-temperature sterilization and new technologies. Revista Latino-Americana de Enfermagem, 2007. DOI: 10.1590/S0104-11692007000300002.

Referências

11 obras citadas

  1. 1WA Rutala e DJ Weber. Low-Temperature Sterilization Technologies: Do We Need to Redefine "Sterilization"?. Infect Control Hosp Epidemiol, 1996quem mais cita →
  2. 2WA Rutala e DJ Weber. Vlinacal Effectiveness of Low Temperature Sterilization Technologies. Infect Control Hosp Epidemiol, 1998quem mais cita →
  3. 3MJ Alfa, P DeGagne, N Olson e mais 1. Comparison of ion plasma, vaporized hydrogen peroxide and 100% ethylene oxide sterilizers to the 12/88 ethylene oxide gas sterilizer. Infect Control Hosp Epidemiol, 1996quem mais cita →
  4. 4WA Rutala, MF Gergen e DJ Weber. Comparative evaluation of the sporicidal activity of new low-temperature sterilization technologies: ethylene oxide, 2 plasma sterilization systems an liquid peracetic acid. Am J Infect Control, 1998quem mais cita →
  5. 5MJ Alfa, P DeGagne, N Olson e mais 1. Comparison of liquid chemical sterilization with peracetic acid and ethylene oxide sterilization for long narrow lumens. Am J Infect Control, 1998quem mais cita →
  6. 6Centers for Disease Control and Prevention. Corneal Decompensation After Intraocular Ophtalmic Surgery - Missouri, 1998. MMWR, 1998quem mais cita →
  7. 7RE Duffy, SE Brown, KL Caldwell e mais 3. An Epidemic of Corneal Destruction Caused by Plasma Gas Sterilization. Arch Ophtalmol, 2000quem mais cita →
  8. 8S Adler, M Scherrer e FD Daschner. Costs of low-temperature plasma sterilization compared with other sterilization methods. J Hosp Infect, 1998quem mais cita →
  9. 9MN Bathina, S Mickelsen, C Brooks e mais 3. Safety and Efficacy of Hydrogen Peroxide Plasma Sterilization for Repeated Use of Electrophysiology Catheters. J Am Coll Cardiol, 1998quem mais cita →
  10. 10SD Ferreira, WS Dernell, BE Powers e mais 3. Effect of Gas-Plasma Sterilization on the Osteoinductive Capacity of Demineralized Bone Matrix. Clin Orthop, 2001quem mais cita →
  11. 11SA Brown, K Merritt, TO Woods e mais 2. Effects of Different Disinfection and Sterilization Methods on Tensile Strength of Materials Use for Single-Use Devices. Biomed Instrum Technol, 2002quem mais cita →

Quem cita esta obra

2 artigos do acervo

ano a anomais citada em 2010 · 1 artigo
Mais citada em 2010, com 1 artigo.
  • 2010: citada em 1 artigo
  • 2011: citada em 1 artigo

quem fala desta obra

6 pessoas

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações