Brazilian Dental Journal2025

Titanium Particles Released from Dental Implants Under Fluoride Exposure Interact with Macrophages

Waad Kheder, Soumya Sheela, A. R. Samsudin, Sausan Al Kawas, Nadia Khalifa e Ali Qabbani

em inglês

cita 31 obras

resumo

Abstract This study is designed to investigate the influence of fluoride and pH value on the release of titanium particles from Ti6Al4V dental implants with hydrophobic microrough surface produced by sandblasting and acid-etching techniques; and correlate particle size to their uptake by macrophages and expression of inflammatory cytokines. Fifteen dental implants were immersed in five test solutions with different fluoride concentrations and pH values. Three control implants were scanned using a scanning electron microscope and fifteen test implants were also scanned after their immersion in the test solutions. The immersion solutions were analyzed for titanium particles/ions size-range and amount. The uptake of titanium particles by macrophages and expression of Il-1 β and IL-8 following their exposure to titanium particles were investigated. Test solutions with high fluoride and acidity resulted in the release of micro-size titanium particles (4551.7 ± 114.5 nm and 2783 ± 101.13 nm); while those with low fluoride, neutral pH, and alkaline environment resulted in the release of nano-size titanium particles (431.2 ± 80.6 nm, 448.3 ± 112 nm, and 484.5 ± 85.3 nm respectively). There was an increase in the uptake of nanoparticles by macrophages without altering their membrane integrity. The increase in expression of IL-1β and IL-8 by M0 macrophages after exposure to titanium dioxide particles may facilitate our understanding of immune cell population-specific molecular events deriving the peri-implant inflammation in response to titanium particles. Fluoride and pH values influence the release of titanium particles from the implant's surface. The activated inflammatory mediators are key to imbalance in osteoblast-osteoclast activity and failure of implant osseointegration.

como citar · ABNT NBR 6023

KHEDER, Waad et al. Titanium Particles Released from Dental Implants Under Fluoride Exposure Interact with Macrophages. Brazilian Dental Journal, 2025. DOI: 10.1590/0103-644020256187.

Referências

31 obras citadas

  1. 1M Han, H Choe e C Chung. Surface characteristics of clinically used dental implant screws. Metals and Materials International, 2005quem mais cita →
  2. 2D Landolt. Electrochemical and materials aspects of tribocorrosion systems. J Phys D Applied Physics, 2006quem mais cita →
  3. 3JCM Souza, SL Barbosa, E Ariza e mais 2. Simultaneous degradation by corrosion and wear of titanium in artificial saliva containing fluorides. Wear, 2012quem mais cita →
  4. 4JCM Souza, P Ponthiaux e M Henriques. Corrosion behavior of titanium in the presence of Streptococcus mutans. J Dent, 2013quem mais cita →
  5. 5A Revathi, AD Borrás, AI Muñoz e mais 2. Degradation mechanisms and future challenges of titanium and its alloys for dental implant applications in oral environment. Mater Sci Eng C Mater Biol Appl, 2017quem mais cita →
  6. 6LMG Fais, RB Fernandes-Filho, MA Pereira-daSilva e mais 2. Titanium surface topography after brushing with fluoride and fluoride-free toothpaste simulating 10 years of use. J Dent, 2012quem mais cita →
  7. 7FH Jones. Teeth and bones: applications of surface science to dental materials and related biomaterials. Surface Science Reports, 2001quem mais cita →
  8. 8N Schiff, B Grosgogeat, M Lissac e mais 1. Influence of fluoride content and pH on the corrosion resistance of titanium and its alloys. Biomaterials, 2002quem mais cita →
  9. 9G Boere. Influence of fluoride on titanium in an acidic environment measured by polarization resistance technique. Journal of applied biomaterials, 1995quem mais cita →
  10. 10JJ Wang, BJ Sanderson e H Wang. Cyto-and genotoxicity of ultrafine TiO2 particles in cultured human lymphoblastoid cells. Mutation Research, 2007quem mais cita →
  11. 11T Albrektsson, D Buser e ST Chen. Statements from the Estepona consensus meeting on peri-implantitis. Clin Implant Dent Relat Res, 2012quem mais cita →
  12. 12JC Wataha, CT Hanks e Z Sun. In vitro reaction of macrophages to metal ions from dental biomaterials. Dent Mater, 1995quem mais cita →
  13. 13T Berglundh, NU Zitzmann e M Donati. Are peri-implantitis lesions different from periodontitis lesions?. J. Clin. Periodontol, 2011quem mais cita →
  14. 14G Thomas, JR Wilson e P Valderrama. Foreign Bodies Associated with Peri-Implantitis Human Biopsies. J. Periodontol, 2015quem mais cita →
  15. 15M Eger, N Sterer, T Liron e mais 2. Scaling of titanium implants entrains inflammation-induced osteolysis. Sci. Rep, 2017quem mais cita →
  16. 16MN Oliveira, WVH Schunemann e MT Mathew. Can degradation products released from dental implants affect peri-implant tissues?. J. Periodontal Res, 2018quem mais cita →
  17. 17O Iocca e G Bianco. Peri-implantitis. Evidence-Based Implant Dentistry, 2016
  18. 18FIF Gomes, MGB Aragão e FCB Barbosa. Inflammatory Cytokines Interleukin-1β and Tumour Necrosis Factor-α - Novel Biomarkers for the Detection of Periodontal Diseases: A Literature Review. J. Oral Maxillofac. Res, 2016quem mais cita →
  19. 19W Chanput, JJ Mes e HJ Wichers. THP-1 cell line: an in vitro cell model for immune modulation approach. Int. Immunopharmacol, 2014quem mais cita →
  20. 20L Reclaru e JM Meyer. Effects of fluorides on titanium and other dental alloys in dentistry. Biomaterials, 1998quem mais cita →
1–20 de 31 obras citadas

Quem cita esta obra

nenhum artigo do acervo cita esta obra — ainda

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações