Brazilian Dental Journal2024

Assessing peri-implant bone microarchitecture: conventional vs. osseodensification drilling - ex vivo analysis

Breno Fortes Bittar, Bruno Salles Sotto-Maior, Karina Lopes Devito, Gustavo Davi Rabelo, Alessandra Silveira Machado, Ricardo Tadeu Lopes e Neuza Maria Souza Picorelli Assis

em inglês

cita 24 obras, 1 no acervo

resumo

Abstract: The aim was to evaluate primary implant stability and bone microarchitecture in two drilling situations, by comparing the conventional technique (CT) and osseodensification (OD) (Versah Burs - Jackson - Mississippi - USA). The implant insertion torque (IT), implant stability quotient (ISQ), and the peri-implant trabecular microstructure were assessed on bone fragments obtained from pig’s tibia (n=12), divided between CT (n=6) and OD (n=6). After the drilling procedure, the implants were installed (3.5x8.5 mm, Epikut - SIN - São Paulo - Brazil). The IT and ISQ were measured using a digital torque wrench and resonance frequency analysis. Then, the bone fragments containing the implants were removed with a trephine and analyzed by Microtomography (µCT, 8.0 µm). The comparison between groups was performed using the unpaired t-test (α=0.05). The results revealed that OD promotes a higher insertion torque (CT: 7.67±2.44 Ncm; OD: 19.78±5.26 Ncm) (p=0.0005), although ISQ was not different (CT: 61.33±4.66; OD: 63.25±4.58) (p=0.48). There was a significant increase in peri-implant bone volume (CT: 23.17±3.39 mm3; OD: 32.01±5.75 mm3) (p=0.008), and trabecular parameters: separation (CT: 0.4357±0.03 mm; OD: 0.3865±0.04 mm) (p=0.0449), number (CT: 1.626±0.18 1/mm; OD: 1.946±0.13 1/mm) (p=0.007), and thickness (CT: 0.1130±0.009 mm; OD: 0.1328±0.015 mm) (p=0.02). Structure model index (SMI) data demonstrate no significant differences between groups (CT: 1.7±0.2; OD: 1.4±0.4) (p=0.12). In conclusion, OD increases the insertion torque values and promotes beneficial changes regarding bone microarchitecture compared with CT, revealing more peri-implant bone volume with consequent higher primary stability.

como citar · ABNT NBR 6023

BITTAR, Breno Fortes et al. Assessing peri-implant bone microarchitecture: conventional vs. osseodensification drilling - ex vivo analysis. Brazilian Dental Journal, 2024. DOI: 10.1590/0103-6440202405599.

Referências

24 obras citadas · 1 no acervo

  1. 1J. Blanco. Influence on early osseointegration of dental implants installed with two different drilling protocols: a histomorphometric study in rabbit. Clin Oral Implants Res, 2011quem mais cita →
  2. 2B. Lahens. The effect of osseodensification drilling for endosteal implants with different surface treatments: A study in sheep. J Biomed Mater Res B Appl Biomater, 2019quem mais cita →
  3. 3A.S Almutairi, M.A. Walid e M.A. Alkhodary. The effect of osseodensification and different thread designs on the dental implant primary stability. F1000Res, 2018quem mais cita →
  4. 4B. Lahens. Biomechanical and histologic basis of osseodensification drilling for endosteal implant placement in low density bone. An experimental study in sheep. J Mech Behav Biomed Mater, 2016quem mais cita →
  5. 5U.Y. Pai. Osseodensification - A novel approach in implant dentistry. J Indian Prosthodont Soc, 2018quem mais cita →
  6. 6P. Trisi. New Osseodensification Implant Site Preparation Method to Increase Bone Density in Low-Density Bone: In Vivo Evaluation in Sheep. Implant Dent, 2016quem mais cita →
  7. 7A. du Plessis. Laboratory x-ray micro-computed tomography: a user guideline for biological samples. Gigascience, 2017quem mais cita →
  8. 8M.L. Bouxsein. Guidelines for assessment of bone microstructure in rodents using micro-computed tomography. J Bone Miner Res, 2010quem mais cita →
  9. 9M.S. Irie. Use of Micro-Computed Tomography for Bone Evaluation in Dentistry. Braz Dent J, 2018no acervo →
  10. 10J.W. Song. Influence of peri-implant artifacts on bone morphometric analysis with micro-computed tomography. Int J Oral Maxillofac Implants, 2013quem mais cita →
  11. 11A.M Gaikwad e A.A. Joshi. Nadgere, Biomechanical and histomorphometric analysis of endosteal implants placed by using the osseodensification technique in animal models: A systematic review and meta-analysis. J Prosthet Dent, 2022quem mais cita →
  12. 12V. Bandela. Comparative Evaluation of Osseodensification Versus Conventional Osteotomy Technique on Dental Implant Primary Stability: An Ex Vivo Study. Cureus, 2022quem mais cita →
  13. 13L.P. Garetto. Remodelling dynamics of bone supporting rigidly fixed titanium implants: a histomorphometric comparison in four species including humans. Implant Dentistry, 1995quem mais cita →
  14. 14F.B Slete e P. Olin. Prasad, Histomorphometric Comparison of 3 Osteotomy Techniques. Implant Dent, 2018quem mais cita →
  15. 15S Huwais e E.G. Meyer. A Novel Osseous Densification Approach in Implant Osteotomy Preparation to Increase Biomechanical Primary Stability, Bone Mineral Density, and Bone-to-Implant Contact. Int J Oral Maxillofac Implants, 2017quem mais cita →
  16. 16F. Javed. Role of primary stability for successful osseointegration of dental implants: Factors of influence and evaluation. Interv Med Appl Sci, 2013quem mais cita →
  17. 17Y. Yamaguchi. Effects of implant thread design on primary stability-a comparison between single- and double-threaded implants in an artificial bone model. Int J Implant Dent, 2020quem mais cita →
  18. 18A Falco e M. Berardini. Trisi, Correlation Between Implant Geometry, Implant Surface, Insertion Torque, and Primary Stability: In Vitro Biomechanical Analysis. Int J Oral Maxillofac Implants, 2018quem mais cita →
  19. 19E.T.P. Bergamo. Osseodensification effect on implants primary and secondary stability: Multicenter controlled clinical trial. Clin Implant Dent Relat Res, 2021quem mais cita →
  20. 20G. Pius. Comparative evaluation of implant stability using bone expanders and conventional osteotomy. J Oral Biol Craniofac Res, 2022quem mais cita →
1–20 de 24 obras citadas

Quem cita esta obra

nenhum artigo do acervo cita esta obra — ainda

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações