Brazilian Dental Journal2018

Segmentation Methods for Micro CT Images: A Comparative Study Using Human Bone Samples

Karla Rovaris, Polyane Mazucatto Queiroz, Karla de Faria Vasconcelos, Lívia dos Santos Corpas, Bernardo Mattos da Silveira e Deborah Queiroz Freitas

em inglês

citado por 1 artigocita 9 obras

resumo

Abstract X-ray microtomography (microCT) is a nondestructive technique used to assess bone morphometry. For an accurate analysis, it is necessary to segment the bone tissue from the background images, avoiding under- or overestimation of the real bone volume. Thus, segmentation methods for microCT can influence the accuracy of bone morphometry analysis. The purpose of this study was to compare two different image segmentation methods available on microCT software (subjective and objective) regarding to the human bone morphometric analysis. Sixteen samples containing a fixation screws covered by 0.5-1mm of bone were scanned using the SkyScan 1173 scanner. Three examiners segmented the microCT images subjectively and recorded the threshold values. Subsequently, an objective segmentation was also done. The 3D analysis was performed for both images using the values​ previously determined in CTAn software. Five bone morphometric parameters were calculated (BV/TV, Tb.Th, Tb.N, Tb.Sp, Conn.Den) and used as dependent variables. ANOVA showed no significant differences between the methods concerning BV/TV (p=0.424), Tb.N (p=0.672), Tb.Th (p=0.183), Tb.Sp (p=0.973) and Conn.Den (p=0.204). Intra- and interobserver agreement ranged from satisfactory to excellent (0.55-1 and 0.546-0.991, respectively). Therefore, results obtained with subjective threshorlding were similar to those obtained with objective segmentation. Since objective segmentation does not have human input and it is a truly objective method, it should be the first choice in microCT studies that concern homogeneity and high resolution human bone sample.

como citar · ABNT NBR 6023

ROVARIS, Karla et al. Segmentation Methods for Micro CT Images: A Comparative Study Using Human Bone Samples. Brazilian Dental Journal, 2018. DOI: 10.1590/0103-6440201801385.

Referências

9 obras citadas

  1. 1PC Chang, K Liang, JC Lim e mais 2. A comparison of the thresholding strategies of micro-CT for periodontal bone loss: a pilot study. Dentomaxillofac Radiol, 2013quem mais cita →
  2. 2W Gómez, E Sales, RT Lopes e mais 1. A comparative study of automatic thresholding approaches for 3D x-ray microtomography of trabecular bone. Med Phys, 2013quem mais cita →
  3. 3D Chappard, N Retailleau-Gaborit, E Legrand e mais 2. Comparison insight bone measurements by histomorphometry and microCT. J Bone Miner Res, 2005quem mais cita →
  4. 4JH Waarsing, JS Day e H Weinans. An improved segmentation method for in vivo microCT imaging. J Bone Miner Res, 2004quem mais cita →
  5. 5N Otsu. A threshold selection method from gray-level histograms”. IEEE Trans Syst Man Cybern, 1979quem mais cita →
  6. 6AM Parfitt, MK Drezner, FH Glorieux e mais 3. Bone histomorphometry: standardization of nomenclature, symbols, and units. Report of the ASBMR histomorphometry nomenclature committee. J Bone Miner Res, 1987quem mais cita →
  7. 7F Butz, T Ogawa, TL Chang e mais 1. Three- Dimensional Bone - Implant Integration Profiling Using Micro-Computed Tomography. Int. J. Oral Maxillofac Implants, 2006quem mais cita →
  8. 8PM Chopra, M Johnson, TR Nagy e mais 1. Clinical Device-Related Article Micro-Computed Tomographic Analysis of Bone Healing Subsequent to Graft Placement. Biomed Mater Res Part B: Appl Biomater, 2009quem mais cita →
  9. 9C Schouten, GJ Meijer, JJP Van den Beucken e mais 2. The quantitative assessment of peri-implant bone responses using histomorphometry and micro-computed tomography. Biomaterials, 2009quem mais cita →

Quem cita esta obra

1 artigo do acervo

quem fala desta obra

4 pessoas

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações