Journal of the Brazilian Chemical Society2017

Exploiting Cork as Biosorbent Extraction Phase for Solid-Phase Microextraction to Determine 3-(4-Methylbenzylidene)camphor and 2-Ethylhexyl 4-(Dimethylamino)benzoate in River Water by Gas Chromatography-Mass Spectrometry

Ana C. Silva, Adriana N. Dias e Eduardo Carasek

em inglês

cita 22 obras

resumo

In this study, a method for the determination of 3-(4-methylbenzylidene)camphor (4-MBC) and 2-ethylhexyl 4-(dimethylamino)benzoate (OD-PABA) in river water samples employing cork as the SPME (solid-phase microextraction) fiber was developed. The extraction parameters optimized were pH, ionic strength and extraction time and temperature. For the extraction step, the sample pH was studied in univariate experiments while the extraction time, temperature and ionic strength were evaluated using a central composite design. The optimal extraction conditions were sample pH 4.0, extraction time 70 min, sample temperature 80 °C and sodium chloride concentration 6% (m v-1). The limits of quantification for 4-MBC and OD-PABA were 0.1 and 0.01 µg L-1, respectively. The linear correlation coefficients were greater than 0.97 for both analytes and the developed method showed recovery values between 67 and 107%. In an evaluation of the fiber-to-fiber reproducibility (fibers produced by different analysts), the relative standard deviation (RSD) was lower than 11% (n = 6).

como citar · ABNT NBR 6023

SILVA, Ana C.; DIAS, Adriana N.; CARASEK, Eduardo. Exploiting Cork as Biosorbent Extraction Phase for Solid-Phase Microextraction to Determine 3-(4-Methylbenzylidene)camphor and 2-Ethylhexyl 4-(Dimethylamino)benzoate in River Water by Gas Chromatography-Mass Spectrometry. Journal of the Brazilian Chemical Society, 2017. DOI: 10.21577/0103-5053.20170085.

Referências

22 obras citadas

  1. 1K. Kim, J. Mueller, Y.-B. Park e mais 4. J. Chromatogr. Sci.. 2011
  2. 2M. Wharton, M. Geary, N. O’Connor e mais 2. J. Chromatogr. Sci.. 2015
  3. 3A. N. Dias, A. C. Silva, V. Simão e mais 2. Anal. Chim. Acta. 2015
  4. 4H. Zhang e H. K. Lee. Anal. Chim. Acta. 2012
  5. 5A. Tovar-Sánchez, D. Sánchez-Quiles, G. Basterretxea e mais 5. PLoS One. 2013
  6. 6M. Pedrouzo, F. Borrull, R. M. Marce e mais 1. TrAC, Trends Anal. Chem.. 2011quem mais cita →
  7. 7M. Vila, J. P. Lamas, C. Garcia-Jares e mais 2. Microchem. J.. 2016
  8. 8E. Magi, C. Scapolla, M. Di Carro e mais 2. Anal. Methods. 2013
  9. 9J. L. Benedé, A. Chisvert, A. Salvador e mais 2. Anal. Chim. Acta. 2014
  10. 10S. C. Cunha, A. Pena e J. O. Fernandes. J. Chromatogr. A. 2015
  11. 11S. Clavijo, J. Avivar, R. Suárez e mais 1. J. Chromatogr. A. 2016
  12. 12M. G. Pintado-Herrera, E. González-Mazo e P. A. Lara-Martín. Anal. Chim. Acta. 2014
  13. 13J. L. Benedé, A. Chisvert, D. L. Giokas e mais 1. Talanta. 2016
  14. 14J. L. Benedé, A. Chisvert, D. L. Giokas e mais 1. J. Chromatogr. A. 2014
  15. 15L. Li, R. Guo, Y. Li e mais 3. Anal. Chim. Acta. 2015
  16. 16T.-E. Wang, M. Guo, W.-L. Song e mais 2. Anal. Methods. 2015
  17. 17W. Song, M. Guo, Y. Zhang e mais 3. J. Chromatogr. A. 2015
  18. 18D. R. Sambandan e D. Ratner. J. Am. Acad. Dermatol. 2011
  19. 19A. N. Dias, V. Simão, J. Merib e mais 1. Anal. Chim. Acta. 2013
  20. 20A. N. Dias, V. Simão, J. Merib e mais 1. Talanta. 2015
1–20 de 22 obras citadas

Quem cita esta obra

nenhum artigo do acervo cita esta obra — ainda

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações