Journal of the Brazilian Chemical Society2016
A Systematic Procedure to Develop a Capillary Electrophoresis Method Using a Minimal Experimental Data
Daniel A. Spudeit, Samantha Gonçalves, Lizandra C. Bretanha, Carlos A. Claumann, Ricardo A. F. Machado e Gustavo A. Micke
em inglês
resumo
The choice of an appropriate background electrolyte (BGE) and its components for capillary electrophoresis analysis is the main step in capillary electrophoresis method development. The use of an inadequate co-ion component could lead to asymmetrical peaks and selecting an inappropriate counter-ion could affect the buffer capacity and the pH of the BGE, leading to unreliable analysis. In this paper, we describe a systematic procedure for the development of a capillary electrophoresis method, based on the effect of varying pH on the ion effective mobility, to optimize the BGE composition. The method was applied to the separation of L-ascorbic acid in different samples. The optimized background electrolyte composition was 40 mmol L-1 tris(hydroxymethyl)aminomethane and 20 mmol L-1 2-morpholinoethanesulfonic acid, at pH 8.1. Sorbic acid was used as the internal standard and separation was carried out in a fused-silica capillary (32 cm total length and 8.5 cm effective length, 50 µm inner diameter), with a short-end-injection configuration and direct ultraviolet (UV) detection at 266 nm. The separation was performed in 26 s. The method shows good linearity (R2 > 0.999), excellent values for inter-day and intra-day precision and good recovery (in the range of 94-107%). The values obtained for limit of detection (LOD) and limit of quantification (LOQ) were 0.14 and 41 mg L-1, respectively. The systematic procedure applied shows to be a very useful tool for the first step method development for capillary electrophoresis.
como citar · ABNT NBR 6023
SPUDEIT, Daniel A. et al. A Systematic Procedure to Develop a Capillary Electrophoresis Method Using a Minimal Experimental Data. Journal of the Brazilian Chemical Society, 2016. DOI: 10.5935/0103-5053.20160087.
Referências
31 obras citadas
- 1S. Terabe, K. Otsuka e H. Nishi. J. Chromatogr. A. 1994
- 2J. P. Landers. Handbook of Capillary and Microchip Electrophoresis and Associated Microtechniques. 2008quem mais cita →
- 3K. F. Johns, M. C. Breadmore, R. Brudo e mais 1. Electrophoresis. 2009
- 4J. P. Vistuba, M. D. Dolzan, L. Vitali e mais 2. J. Chromatogr. A. 2015
- 5M. Piovezan, A. C. O. Costa, A. V. Jager e mais 2. Anal. Chim. Acta. 2010
- 6L. Vitali, V. T. Favere e G. A. Micke. J. Chromatogr. A. 2011
- 7A. Meister. Biochem. Pharmacol. (Amsterdam, Neth.). 1992quem mais cita →
- 8N. Nasirizadeh, Z. Shekari, M. Tabatabaee e mais 1. J. Braz. Chem. Soc.. 2015
- 9A. A. Alwarthan. Analyst (Cambridge, U. K.). 1993quem mais cita →
- 10M. Bottegal, L. Lang, M. Miller e mais 1. Rapid Commun. Mass Spectrom.. 2010quem mais cita →
- 11H. W. Park, S. M. Alam, S. H. Lee e mais 4. Luminescence. 2009
- 12D. J. Fischer, M. K. Hulvey, A. R. Regel e mais 1. Electrophoresis. 2009
- 13S. L. Zhao, Y. Huang e Y. M. Liu. J. Chromatogr. A. 2009
- 14S. Q. Dong, S. Zhang, X. Cheng e mais 3. J. Chromatogr. A. 2007
- 15X. L. Wang, L. J. Li, Z. Y. Li e mais 3. J. Electroanal. Chem.. 2014
- 16M. C. Marra, P. L. Silva, R. A. A. Munoz e mais 1. J. Braz. Chem. Soc.. 2014
- 17Y. J. Tang e M. J. Wu. Talanta. 2005
- 18O. K. Choi e J. S. Jo. J. Chromatogr. A. 1997
- 19K. Fukushi, S. Takeda, S. Wakida e mais 3. J. Chromatogr. A. 1997
- 20M. W. Davey, G. Bauw e M. VanMontagu. Anal. Biochem.. 1996
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda